    							2. PCB Installation
    2-9
    INSTALLING PCBs
    Digital Station (16DSTU) PCB(Figures 2-6 and 2-7)
    The 16DSTU provides connection for
    16 digital telephones. Refer to Section
    3, Installing Extensions and Trunksfor
    wiring instructions.To install the 16DSTU PCB:
    1. Plug the 16DSTU PCB for exten-
    sions 300-315 into slot CN1.
    2. Plug in additional 16DSTU PCBs as
    required. See System Configuration
    in Section 1 for more.
    3. Set the mode switch on each
    installed 16DSTU to RUN.
    Figure 2-6  DIGITAL STATION (16DSTU) PCB
    Figure 2-7  INSTALLING THE 16DSTU PCB
    80000 - 31
    Mode
    Switch
    4 Slot Cabinet
    Shown 
    						
    							INSTALLING PCBS
    2-10
    Analog Station (8ASTU and 4ASTU) PCBs
    (Figures 2-8 and 2-9)
    The 8ASTU PCB provides connection
    for 8 analog extensions. The 4ASTU
    PCB connects 4 analog extensions.
    Refer to Section 3, Installing Extensions
    and Trunksfor wiring instructions.To install the ASTU PCB:
    1. Plug in ASTU PCBs as required.
    In U Slot systems, see System
    Configuration in Section 1.
    In Fixed Slot systems, you can only
    plug an ASTU PCB into slot CN2.
    An 8ASTU PCB provides analog
    extensions 316-323. A 4ASTU PCB
    provides analog extensions 316-319.
    2. Set the mode switch on the ASTU to
    RUN.
    Figure 2-8  ANALOG STATION (ASTU) PCBFigure 2-9  INSTALLING THE ASTU PCB
    80000 - 31A
    Mode
    Switch
    4 Slot Cabinet
    Shown 
    						
    							2. PCB Installation
    2-11
    INSTALLING PCBs
    Analog Trunk (8ATRU and 4ATRU) PCBs
    (Figures 2-10 and 2-11)
    The 8ATRU provides connection for 8
    loop start analog trunks. The 4ATRU
    PCB connects 4 loop start analog trunks.
    Refer to Section 3, Installing Extensions
    and Trunksfor wiring instructions.To install ATRU PCBs:
    1. Install ATRU PCBs as required.
    In U Slot systems, see System
    Configuration in Section 1.
    In Fixed Slot systems, plug the
    8ATRU PCB for trunks 1-8 into slot
    CN3. Plug the 8ATRU PCB for
    trunks 9-16 into slot CN4.
    In Fixed Slot systems, a 4ATRU
    PCB enables the first 4 trunks (1-4)
    but disables the second 4 (5-8).
    With 2 4ATRU PCBs installed, you
    system has trunks 1-4 and 9-12.
    3. Set the mode switch on each installed 8ATRU to RUN.
    Figure 2-10  ANALOG TRUNK (ATRU) PCBFigure 2-11  INSTALLING THE 8ATRU PCB
    80000 - 32
    Mode
    Switch
    4 Slot Cabinet
    Shown 
    						
    							INSTALLING PCBs
    2-12
    8 Circuit Caller ID Daughter Board (Figure 2-12)
    For Caller ID capability, install 8 circuit Caller ID PCB daugh-
    ter boards (P/N 80013) on the 8ATRU PCBs (P/N 80011A
    ).
    The Caller ID PCB provides Caller ID capability for all eight
    trunk circuits on the 8ATRU PCB.  Every 8ATRU PCB in the
    system can have a Caller ID daughter board.
    If you are installing Caller ID on an 8ATRU PCB in the
    last slot, you may have to adjust your system’s ground
    wire connection so it won’t obstruct the daughter board.
    To install ATRU PCBs:
    1. Remove the metal bracket that holds the PCBs in place.
    2. Remove the 8ATRU PCB.
    3. Remove the headers from 8ATRU PCB connectors CN3 and
    CN4 and store in a safe place (see Figure 2-12).
    4. Align the Caller ID PCB standoffs over the holes located in
    the 8ATRU PCB.
    Note that the CN2 connector on the Caller ID PCB
    should be above the CN3 connector on the 8ATRU
    PCB. CN3 on the Caller ID PCB should be above CN4
    on the 8ATRU PCB. CN1 on the Caller ID PCB should
    be above CN2.5. Push the PCB down until the standoffs snap into place.
    6. Plug the 8ATRU PCB back into the system cabinet.
    7. Refer to your system’s Software Manualfor additional fea-
    ture information and any required system programming. 
    						
    							2. PCB Installation
    2-13
    INSTALLING PCBs
    CN2
    CN1
    CN2 CN3
    Remove
    headers
    Push PCB down at outside edges
    until standoffs snap into place
    CN4
    CN3
    80013 - 1
    Figure 2-12  INSTALLING THE 8 CIRCUIT CALLER ID DAUGHTER BOARD 
    						
    							INSTALLING PCBs
    2-14
    4 Circuit Caller ID Daughter Board (Figure 2-13)
    For Caller ID capability, install 4 circuit Caller ID PCB daugh-
    ter boards (P/N 92012) on the 4ATRU PCBs (P/N 80010A
    ).
    The Caller ID PCB provides Caller ID capability for all four
    trunk circuits on the 4ATRU PCB. Every 4ATRU PCB in the
    system can have a Caller ID daughter board.
    If you are installing Caller ID on a 4ATRU PCB in the
    last slot, you may have to adjust your system’s ground
    wire connection so it won’t obstruct the daughter board.
    To install ATRU PCBs:
    If you install a P/N 92012 Caller ID PCB on an
    8ATRU PCB P/N 80011A, you will get Caller ID ser-
    vice only on the first four PCB trunk circuits.
    1. Remove the metal bracket that holds the PCBs in place.
    2. Remove the 4ATRU PCB.
    3. Remove the headers from 4ATRU PCB connector CN3 and
    store in a safe place (see Figure 2-13).
    4. Align the Caller ID PCB standoffs over the holes located in
    the 4ATRU PCB.Note that the CN2 connector on the Caller ID PCB
    should be above the CN3 connector on the 4ATRU
    PCB. CN1 on the Caller ID PCB should be above CN2.
    5. Push the PCB down until the standoffs snap into place.
    6. Plug the 4ATRU PCB back into the system cabinet.
    7. Refer to your system’s Software Manualfor additional fea-
    ture information and any required system programming. 
    						
    							2. PCB Installation
    2-15
    INSTALLING PCBs
    Figure 2-13  INSTALLING THE 4 CIRCUIT CALLER ID DAUGHTER BOARD
    CN2
    CN1
    CN2 CN3
    Remove
    headers
    92012 - 2
    Push PCB down at outside edges
    until standoffs snap into place 
    						
    							2-16
    CONNECTING BLOCKS
    Working With 8-Pin Jacks
    The system uses 8-pin mod jacks to connect extensions, trunks
    and optional equipment. Using the Installation Cable (P/N
    80892) makes it easy to connect the PCBs to standard 66M1-50
    connecting blocks. These cables have 6 8-pin modular jacks on
    one end and are unterminated on the other. In general, each cab-
    inet needs:
    One 66M1-50 block and Installation Cable (P/N 80892) for
    extensions and optional equipment.
    
    One 66M1-50 block and Installation Cable (P/N 80892) for
    trunks.
    Note:Depending on your PCB configuration and local codes,
    you may need an additional 66M1-50 block and
    Installation Cable (P/N 80892) for optional equipment.
    Punching Down the Cables (Figures 2-14 to 2-18)
    The Installation Cables have 6 8-pin jacks installed on one end
    and are unterminated on the other. Each 8-pin jack connects 4
    extensions or 4 trunks.
    1. For each 66M1-50 block, punch down the Installation Cable
    in standard color-code order.
    Use Figure 2-14 when connecting extensions.Use Figure 2-15 when connecting trunks.
    2. After you have punched down your cables, route them
    through the side of the cabinet and secure them with the
    strain relief (Figure 2-16).
    3. If you are using non-A PCBs (e.g., 16DSTU PCB P/N 80021)
    in a 4 Slot Cabinet, be sure to install RFI Suppressor
    Assemblies on each station and trunk cable. Follow Figure 2-
    17 and snap an assembly around each 50-pin cable.You cannot use non-A PCBs in an 8 Slot Cabinet.
    Making your own Cables (Figure 2-18)
    If you want to make your own cables (instead of using
    Installation Cable P/N 80892), follow the pinouts in Figure 2-18. 
    						
    							2. PCB Installation
    2-17
    CONNECTING BLOCKS
    WHT-BLU
    BLU-WHT
    WHT-ORN
    ORN-WHT
    WHT-GRN
    GRN-WHT
    WHT-BRN
    BRN-WHT
    WHT-SLT
    SLT-WHT
    RED-BLU
    BLU-RED
    RED-ORN
    ORN-RED
    RED-GRN
    GRN-RED
    RED-BRN
    BRN-RED
    RED-SLT
    SLT-RED
    BLK-BLU
    BLU-BLK
    BLK-ORN
    ORN-BLK
    BLK-GRN
    GRN-BLK
    BLK-BRN
    BRN-BLK
    BLK-SLT
    SLT-BLK
    YEL-BLU
    BLU-YEL
    YEL-ORN
    ORN-YEL
    YEL-GRN
    GRN-YEL
    YEL-BRN
    BRN-YEL
    YEL-SLT
    SLT-YEL
    VIO-BLU
    BLU-VIO
    VIO-ORN
    ORN-VIO
    VIO-GRN
    GRN-VIO
    VIO-BRN
    BRN-VIO
    VIO-SLT
    SLT-VIO 1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    505
    4
    3
    6
    2
    7
    1
    8
    5
    4
    3
    6
    2
    7
    1
    8
    5
    4
    3
    6
    2
    7
    1
    8
    5
    4
    3
    6
    2
    7
    1
    8
    5
    4
    3
    6
    2
    7
    1
    8
    5
    4
    3
    6
    2
    7
    1
    8 300  T
    300  R
    301  T
    301  R
    302  T
     302  R
    303  T
    303  R
    304  T
    304  R
    305  T
    305  R
    306  T
    306  R
    307  T
    307  R
    308  T
    308  R
    309  T
    309  R
    310  T
    310  R
    311  T
    311  R
    312  T
    312  R
    313  T
    313  R
    314  T
    314  R
    315  T
    315  R
    316  T
    316  R
    317  T
    317  R
    318  T
    318  R
    319  T
    319  R
    320  T
    320  R
    321  T
    321  R
    322  T
    322  R
    323  T
    323  R
    NC
    NC
    BLOCK
    TERM25-PAIR CABLE
    COLOR
    CODEFUNCTION RJ-61X RJ61X
    1
    2
    3
    4
    80000 - 19A
    Extensions 300-323 Shown 8ASTU PCB
    5
    6
    PCB Location
    1 8
    RJ-61X Plug
    16DSTU PCB
    134
    256
    Figure 2-14  CONNECTING EXTENSIONS
    For Power Failure
    Telephone connections,
    refer to Section 4,
    Optional Equipment. 
    						
    							2-18
    CONNECTING BLOCKS
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    501  T
    1  R
    2  T
    2  R
    3  T
    3  R
    4  T
    4  R
    5  T
    5  R
    6  T
    6  R
    7  T
    7  R
    8  T
    8  R
    9  T
    9  R
    10  T
    10  R
    11   T
    11  R
    12  T
    12  R
    13  T
    13  R
    14  T
    14  R
    15  T
    15  R
    16  T
    16  R WHT-BLU
    BLU-WHT
    WHT-ORN
    ORN-WHT
    WHT-GRN
    GRN-WHT
    WHT-BRN
    BRN-WHT
    WHT-SLT
    SLT-WHT
    RED-BLU
    BLU-RED
    RED-ORN
    ORN-RED
    RED-GRN
    GRN-RED
    RED-BRN
    BRN-RED
    RED-SLT
    SLT-RED
    BLK-BLU
    BLU-BLK
    BLK-ORN
    ORN-BLK
    BLK-GRN
    GRN-BLK
    BLK-BRN
    BRN-BLK
    BLK-SLT
    SLT-BLK
    YEL-BLU
    BLU-YEL
    YEL-ORN
    ORN-YEL
    YEL-GRN
    GRN-YEL
    YEL-BRN
    BRN-YEL
    YEL-SLT
    SLT-YEL
    VIO-BLU
    BLU-VIO
    VIO-ORN
    ORN-VIO
    VIO-GRN
    GRN-VIO
    VIO-BRN
    BRN-VIO
    VIO-SLT
    SLT-VIO
    BLOCK
    TERM25-PAIR CABLE
    COLOR
    CODEFUNCTION RJ61X
    1
    2
    3
    4
    NC
    80000 - 20
    Trunks 1-16PCB Location
    8ATRU PCB8ATRU PCB
    134
    N/CN/C
    56
    2
    5
    4
    3
    6
    2
    7
    1
    8
    5
    4
    3
    6
    2
    7
    1
    8
    5
    4
    3
    6
    2
    7
    1
    8
    5
    4
    3
    6
    2
    7
    1
    8
    5
    4
    3
    6
    2
    7
    1
    8
    5
    4
    3
    6
    2
    7
    1
    8 RJ-61X
    1 8
    RJ-61X Plug
    Figure 2-15  CONNECTING TRUNKS 
    						