Home > NEC > Communications System > NEC Ds2000 Hardware Manual Instructions Manual

NEC Ds2000 Hardware Manual Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Ds2000 Hardware Manual Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							6. Specifications
    and Parts
    6-1
    Section 6, SPECIFICATIONS AND PARTS LIST
    In this section . . . PageSpecifications  . . . . . . . . . . . . . . . . . . . . . . .6-2
    Parts List  . . . . . . . . . . . . . . . . . . . . . . . . . . .6-6 
    						
    							6-2
    SPECIFICATIONS
    System Capacities
    Conference Circuits 32 Conference circuits
    dynamically allocated, with
    8 parties max. per
    Conference. Conference
    circuits provided on CPU.
    8ATRU Analog Trunk  PCB:Refer to System Config-
    4ATRU Analog Trunk  PCB:uration - U Slot on page
    16DSTU Digital Station PCB:1-15 and System Config-
    8ASTU Analog Station PCB:uration - Fixed Slot on 
    4ASTU Analog Station PCB:page 1-18 for capacities.
    CPU Central Processing Unit: 1
    REJ Recording Jack Units 1 max. per keyset
    System Capacities
    Cabinets: 1
    Talk Timeslots (Intercom/line): Non-blocking
    Analog Trunks (CO/PBX lines): 4 Slot Fixed: 16
    4 Slot U: 24
    8 Slot U: 48
    Digital and/or Analog Telephones: 4 Slot Fixed: 32
    4 Slot U: 40
    8 Slot U: 96
    DSS Consoles: 1 max. per keyset, 4 max.
    per system
    Power Failure Telephones: 2 per ATRU PCB
    Door Boxes (digital): 1 per digital station port
    External Paging Zones: 1 (1 per CPU)
    Internal Paging Zones: 8 (7 and All Call) 
    						
    							6. Specifications
    and Parts
    6-3
    SPECIFICATIONS
    Electrical Specifications
    The following specifications apply to each power supply installed.
    Power Supply: 120 VAC ±- 10% @ 50-60 Hz
    Output Power 91 Watts @ 100% full load
    Input Current 1.50A @ 110 V
    VA 165
    Kwh .165
    BTU 563
    Grounding Requirements: 12 AWG copper wire
    Environmental Specifications
    Cabinets and Key Telephones
    Temperature: 0-45
    oC (32-113
    oF)
    Humidity: 10-95% (non-condensing)
    Door Box
    Temperature: 0-45
    oC (32-113
    oF)
    Humidity: 10-95% (non-condensing)
    Not intended for outdoor installation.
    Power Requirements
    A dedicated 110 VAC 60 Hz circuit located within seven feet
    of the cabinet is required. You should install a separate dedi-
    cated outlet for each cabinet.
    Environmental Requirements
    Meeting established environmental standards maximizes the
    life of the system. Refer to the Standard Practices Manual for
    further information. Be sure that the site is not:
    1. In direct sunlight or in hot, cold or humid places.
    2. In dusty areas or in areas where sulfuric gases are produced.
    3. In places where shocks or vibrations are frequent or strong.
    4. In places where water or other fluids comes in contact with
    the main equipment.
    5. In areas near high-frequency machines or electric welders.
    6. Near computers, telexes, microwaves, air conditioners, etc.
    7. Near radio antennas (including shortwave).
    T
    i
    d
    c 
    						
    							6-4
    SPECIFICATIONS
    External Paging
    Output Impedance: 600 Ohm
    Output Level: 0 dBr at 1.0 KHz
    CPRU Relay Contacts
    Contact Configuration: Normally open
    Maximum Load: 60 mA @ 30 VDC
    10 mA @ 90 VDC
    Maximum Initial Contact Resistance: 50 mOhms
    Mechanical Specifications
    Equipment Width Depth Height Weight
    4-Slot KSU 10 3/4””5 7/8””13 11/16”4 lbs 5 oz
    8-Slot KSU 19 1/2””5 7/8””13 11/16”6 lbs 12 oz
    Non-display Keyset 7 1/4”9”2 7/8””1 lb 11 oz
    Display Keyset 7 1/4”9”2 7/8”1 lb 12 oz
    Super Display Keyset 7 1/4”9”2 7/8”1 lb 16 oz
    DSS Console 7 7/8”8 7/8”2 3/4”1 lb 6 oz
    Door Box 4”1 1/2”5 3/16”10 oz
    2-OPX Module 9 3/8”7 3/8”1 1/4”3 lbs 
    						
    							6. Specifications
    and Parts
    6-5
    SPECIFICATIONS
    Cabling Requirements
    1. Do not run station cable parallel with the AC source, telex or com-
    puter, etc. If the cables are near cable runs to those devices, use
    shielded cable with grounded shields or install the cable in conduit.
    2. When cables must be run on the floor, use cable protectors.
    3. Cable runs for key telephones, single line telephones, and Door
    Boxes must be a dedicated, isolated cable pair.Device Cable Type Cable Run Length (ft) Notes
    Key Telephone, 2-wire 26 AWG 1300
    2-wire 24 AWG 2000
    Single Line 2-wire 26 AWG 11,500 at constant 20 mA
    Telephone 3150 at constant 35 mA
    2-wire 24 AWG 18,000 at constant 20 mA
    5050 at constant 35 mA
    2-wire 22 AWG 29,000 at constant 20 mA
    8000 at constant 35 mA
    Door Box 2-wire 24 AWG 2000
    2-wire 22 AWG 2000
    2-OPX 2-wire 24 AWG 1000
    FCC Registration Information
    Model: DS2000
    Manufacturer: NEC Infrontia, Inc.
    FCC Part 15 Registration: Class A
    FCC Registration Number: 1ZDTHA27007-KF-E
    1ZDTHA27044-MF-E
    Industry CanadaCertificate (DOC) Number 854 9522 AReg. FIC Mfrs. Port Network
    Status Identifier JacksOriginal 02LS2 80010 REN 0.6B RJ11C
    80011 RJ21X
    Registered OL13A 2OPX-A SOC 9.0F RJ21X
    OL13B 2OPX-A SOC 9.0F RJ21X
    OL13C 2OPX-A SOC 9.0F RJ21X
    BGM/MOH Music Source Input
    Input Impedance: 10K Ohms
    Input Level: +18 dBr (+/- 2 dBr) t 1.0
    KHz
    Music input is located on the CPU PCB. 
    						
    							6-6
    PARTS LIST
    Common Equipment
    Description Part Number
    4-Slot KSU 80000
    8-Slot KSU 80001
    DS2000 Power Supply 80005
    80005A
    Installation Cable 80892
    Blank PC Card 85880
    PC Card with system software preloaded 80051-V**.**
    (**.** denotes the system software level)
    8-Pin DIN to Mod-8 Cable 80893
    DB9 to Mod-8 Adaptor 85980
    DB25 to Mod-8 Adaptor 85981
    Spare KSU Hanger 80578
    You must use an A version Power Supply in an 8 Slot Cabinet
    Peripheral Station Equipment
    Description Part Number
    2-OPX Module 92177A
    DS2000 Digital Door Box 80560
    Station Equipment
    Description Part Number
    34-Button Super Display Telephone 80673
    34-Button Display Telephone 80663
    22-Button Telephone 80570
    22-Button Display Telephone 80573
    24-Button DSS Console 80556
    110-Button DSS Console 80555
    Wall Mount Kit 80579
    Analog Telephones (customer provided) 
    						
    							6. Specifications
    and Parts
    6-7
    PARTS LIST
    Replacement Parts
    Description Part Number
    Handset and Cord Assembly 80150
    Noise Canceling Handset 80150NC
    Handset Coil Cord - Black 9’92297-9
    Handset Coil Cord - Black 13’92297-13
    Handset Coil Cord - Black 25’92297-25
    Telephone Line Cord - Black 7”82476-7
    Telephone Line Cord - Black 14”82476-14
    34 Btn Super Display Tel Clear Plastic Cover 80600-S34
    34 Btn Tel Clear Plastic Cover 80600-34
    22 Btn Tel Clear Plastic Cover 80600-22
    110-Button DSS Console Clear Plastic Cover 80600-DSS
    24-Button DSS Console Clear Plastic Cover 80600-24DSS
    Directory Tray 92602
    Wall Mount Handset Clip Holder 80578
    DS2000 RFI Bead Kit 88901
    PCBs
    Description Part Number
    CPU Central Processing Unit 80025
    80025A
    16DSTU Digital Station PCB 80021
    80021A
    8ASTU 8 Port Analog Station PCB 80041
    80041A
    4ASTU 4 Port Analog Station PCB 80040
    80040A
    4ATRU 4 Port Analog Trunk PCB (loop start) 80010
    80010A
    8ATRU 8 Port Analog Trunk PCB (loop start) 80011
    80011A
    4 Circuit Caller ID Daughter Board 92012
    Installs on 4ATRU PCB P/N 80010A
    8 Circuit Caller ID Daughter Board 80013
    Installs on 8ATRU PCB P/N 80011A
    You must use all A version PCBs in an 8 Slot Cabinet 
    						
    							Th
    6-9
    co
    NEC America, Inc., Corporate Networks Group
    4 Forest Parkway, Shelton, CT 06484
    Tel: 800-365-1928   Fax: 203-926-5458
    cng.nec.comOther Important Telephone Numbers
    Sales:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203-926-5450
    Customer Service:  . . . . . . . . . . . . . . . . . . . . . . . . . . .203-926-5444
    Customer Service FAX:  . . . . . . . . . . . . . . . . . . . . . . .203-926-5454
    Technical Service:  . . . . . . . . . . . . . . . . . . . . . . . . . . .203-925-8801
    Discontinued Product Service:  . . . . . . . . . . . . . . . . . .900-990-2541
    Technical Training: . . . . . . . . . . . . . . . . . . . . . . . . . . .203-926-5430
    Emergency Technical Service (After Hours)  . . . . . . . .203-929-7920
    (Excludes discontinued products) 
    						
    							NEC America, Inc., Corporate Networks Group
    4 Forest Parkway, Shelton, CT 06484
    TEL: 203-926-5400  FAX: 203-929-0535
    cng.nec.com 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Ds2000 Hardware Manual Instructions Manual