Home > NEC > Communications System > NEC Ds2000 Hardware Manual Instructions Manual

NEC Ds2000 Hardware Manual Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Ds2000 Hardware Manual Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							4. Optional
    Equipment
    Section 4, INSTALLING OPTIONAL EQUIPMENT
    In this section . . .
    Page
    DSS Console  . . . . . . . . . . . . . . . . . . . . . . .4-14
    Installing a DSS Console . . . . . . . . . . . . . . . 4-14
    Programming DSS Consoles . . . . . . . . . . . . . 4-14
    2-OPX Module  . . . . . . . . . . . . . . . . . . . . .4-16
    Installing the 2-OPX Module . . . . . . . . . . . . 4-16
    Programming 2-OPX Modules . . . . . . . . . . . 4-16
    Wall Mounting the 2-OPX Module . . . . . . . . 4-18
    Wall-Mount Kit  . . . . . . . . . . . . . . . . . . . . .4-20
    Installing the Wall-Mount Kit . . . . . . . . . . . . 4-20
    Installing the Wall-Mount Handset Hanger . . 4-20
    Wall-Mounting a Key Telephone. . . . . . . . . . 4-21
    Desk Stand  . . . . . . . . . . . . . . . . . . . . . . . .4-25
    Using the Desk Stand . . . . . . . . . . . . . . . . . . 4-25
    REJ Recording Jack  . . . . . . . . . . . . . . . . .4-26
    Installing the REJ Recording Jack. . . . . . . . . 4-26
    In this section . . .
    Page
    External Paging  . . . . . . . . . . . . . . . . . . . . .4-2
    Installing External Paging . . . . . . . . . . . . . . . . 4-2
    Door Box  . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4
    Installing the Digital Door Box . . . . . . . . . . . . 4-4
    Programming the Digital Door Box . . . . . . . . 4-6
    Operating the Digital Door Box . . . . . . . . . . . 4-7
    CPRU Relays  . . . . . . . . . . . . . . . . . . . . . . .4-8
    Connecting to the CPRU Relays . . . . . . . . . . . 4-8
    Music Sources  . . . . . . . . . . . . . . . . . . . . . .4-10
    Installing a Music Source . . . . . . . . . . . . . . . 4-10
    Programming Background Music . . . . . . . . . 4-10
    Programming Music on Hold . . . . . . . . . . . . 4-10
    Power Failure Telephones  . . . . . . . . . . . . .4-12
    Power Failure Cut-Through . . . . . . . . . . . . . 4-12
    4-1 
    						
    							4-2
    EXTERNAL PAGING
    Installing External Paging (Figure 4-1)
    The CPU provides an External Paging output. You connect the
    CPU Paging output to audio inputs on customer provided
    Paging systems.To connect an External Paging amplifier:
    1. Find an available connector in a station cable and make sure
    it is correctly punched down at the 66M1-50 block.
    Follow standard color code order. Be sure the block is
    properly cross-connected.
    2. For the connector chosen, locate pins 1T and 1R (see Figure
    4-1) and connect the music source.
    3. Plug the modular jack into the CPU modular connector.
    Be sure the connected Paging equipment is compatible with the
    following CPU page output specifications:
    Output Impedance: 600 Ohms
    Output Level: 0 dBr @ 1.0 kHz
    4-t
    he
    ys-
    s to
    .
    ose
    pli-
    ed
    Be
    -
    u-
    t- 
    						
    							4. Optional
    Equipment
    4-3
    EXTERNAL PAGING
    Figure 4-1  CONNECTING EXTERNAL PAGINGRJ61X 
    Pin
    Latch
    faces upTo CPU
    Mod Jack
    Note
    reversalPort
    DesignationTo 66 Block
    WHT-BLU (1T)
    BLU-WHT (1R)
    WHT-ORN (2T)
    ORN-WHT (2R)
    WHT-GRN (3T)
    GRN-WHT (3R)
    WHT-BRN (4T)
    BRN-WHT (4R)
    80000 - 18B
    4T
    3T
    2T
    1R
    1T
    2R
    3R
    4R
    1
    2
    3
    4
    5
    6
    7
    8
    Page OutMusic InRelay ContactsNo Connection
    The following products should help if you make your own cables:Suttle SE-266-8K 8 Position Modular Plug (requires an SE-166
    or SE-166-6 modular crimping tool).Hubbell BRFTP4P Snap-On 8 Position Modular Plug (does not
    require a special crimping tool).
    Check with your local supplier for other comparable products. 
    						
    							4-4
    DOOR BOX
    Installing the Digital Door Box (Figure 4-2)
    The Digital Door Box (P/N 80560) is a self-contained Intercom
    unit typically used to monitor an entrance door. A visitor at the
    door can press the Door Box call button (like a door bell). The
    Door Box then sends chime tones to all extensions programmed
    to receive chimes. To answer the chime, the called extension
    user just lifts the handset. This lets the extension user talk to the
    visitor at the Door Box. The Door Box is convenient to have at
    a delivery entrance, for example. It is not necessary to have
    company personnel monitor the delivery entrance; they just
    answer the Door Box chimes instead.
    The number of Door Boxes you can install is limited by the
    System Load Factor. (see page 1-16).
    The Door Box is a weather-tight unit, with an operating temper-
    ature range of 0 to 45 degrees C (32 to 113 degrees F) and a
    relative humidity of 10-95%, non-condensing. It is not intended
    for outdoor installation.
    Any available 16DSTU PCB port can support a Digital Door Box.
    To install the Digital Door Box:
    1. Snap open the Door Box case.
    2. Punch down one end of a two-pair twisted station cable on
    the extension block as shown in Figure 4-2.
    3. Run the station cable through the hole in the back of the
    Door Box.
    When wall mounting, use the two holes in the base of
    the Door Box for the mounting screws.
    4. Strip the conductors back about 1/2 inch and connect to the
    Door Box terminals.
    5. Snap the Door Box cover back onto the base.
    Also see Programming the Door Boxon page 4-6 and
    Operating the Door Boxon page 4-7. 
    						
    							4. Optional
    Equipment
    4-5
    DOOR BOX
    Figure 4-2  CONNECTING A DOOR BOX
    80000 - 39A
    9
    10
    11
    12
    13
    14
    White/Blue
    Mounting screws
    (Customer provided)
    Digital Door Box
    (P/N 80560) Digital Door Box
    (Extension 304)
    Station Cable
    Lead Designations
    Blue/White
    White/Blue
    Blue/White
    TT
    TR 
    						
    							4-6
    DOOR BOX
    Programming the Digital Door Box
    Door Box Setup 
    You must assign the circuit type and chime pattern to each
    installed Door Box.
    In 1801: Extension Circuit Type, enter 10 to assign the
    extension as a Door Box.
    
    In 1801: Door Chime, enter the Door Chime type.
    0 = Normal Ring Group ringing.
    1 = Low pitch chime pattern.
    2 = Mid range pitch chime pattern.
    3 = High pitch chime pattern.
    If you enter Door Chime type 0 (normal ring) above,
    you can set up Call Coverage keys for the Ring Group.
    This allows extensions that are not members of the Ring
    Group to answer Door Box calls. Extensions with Call
    Coverage keys to the Door Box Ring Group can also
    activate the relay (see Door Box Relay Control below).
    Door Box Ringing 
    When a visitor at the door presses the Door Box call button, the
    Door Box with alert (chime) all the extensions in the Ring
    Group to which the Door Box belongs. For example, if theDoor Box and extensions 301 and 302 are in Ring Group 1,
    pressing the call button alerts 301 and 302.
    
    In 1802: Ring Group Number, assign the Door Box and
    the extensions that should alert to the same Ring Group.
    
    In 0511: Ring Group Master Extension Numbers and
    Names, assign a Ring Group master number to the Ring
    Group assigned in the previous step.
    Door Box Relay Control 
    If the relay on the CPRU controls the strike for the door, the
    keyset that answers the Door Box chimes can remotely open
    and close the strike. Refer to Connecting to the CPRU Relays
    on page 4-8 for more on setting up this option.
    
    In 1801: Relay Owner, enter 1 to assign the CPRU PCB
    relay to the Door Box (see Operating the Door Box below).
    Enter 0 to disable the CPRU PCB relay for Door Box calls.
    
    In 0401: Door Unlock Time, enter the interval that the
    CPRU relay should remain closed after the keyset user acti-
    vates (closes) the relay. After this interval, the CPRU auto-
    matically returns to its idle (open) state. 
    						
    							4. Optional
    Equipment
    4-7
    DOOR BOX
    Operating the Door Box
    To place a call from the Door Box:
    1. Press the Door Box call button.
    2. When someone inside the building answers your call, speak
    toward the Door Box.
    To place a call to the Door Box:
    1. Lift handset and press 
    ICM
    .
    2. Dial the Door Box extension number.
    To answer the Door Box chimes from a keyset:
    1. Lift handset or press 
    SPK
    .To control the CPRU relay which in turn controls the
    door strike:
    Once set up in programming, this option is available
    to any member of the Door Box Ring Group as well as
    any extension with a Call Coverage Key for the Door
    Box Ring Group.
    1. To open the relay, press 
    FLASH
    key or 
    OPEN
    soft key.
    2. To close the relay, press 
    FLASH
    key again or 
    CLOSE
    soft key. 
    						
    							4-8
    CPRU RELAYS
    Connecting to the CPRU Relays (Figure 4-3)
    Any keyset extension that receives Door Box chimes can con-
    trol the CPRU relay, which in turn typically enables an electric
    strike on an entrance door next to a Door Box. After answering
    the Door Box chimes, the extension user can press a FLASH or
    a soft key to enable the associated relay. The visitor at the door
    can then enter without having an employee open the entrance
    for them.To connect to the CPRU Relays:
    1. Find an available connector in a station cable and make sure
    it is correctly punched down at the 66M1-50 block.
    Follow standard color code order. Be sure the block is
    properly cross-connected.
    2. For the connector chosen, locate pins 3T and 3R (see Figure
    4-3) and connect to the device the relays will control.
    3. Plug the modular jack into the CPU modular connector.Be sure the equipment connected to the relays is compatible
    with the following CPU relay specifications:
    Contact Configuration  . .Normally open
    Maximum Load  . . . . . . .60 mA @ 30 VDC
    10 mA @ 90 VDC
    Maximum Initial Contact Resistance  . .50 mOhms 
    						
    							4. Optional
    Equipment
    4-9
    CPRU RELAYS
    Figure 4-3  CONNECTING CONTROL RELAYS
    RJ61X 
    Pin
    Latch
    faces upTo CPU
    Mod Jack
    Note
    reversalPort
    DesignationTo 66 Block
    WHT-BLU (1T)
    BLU-WHT (1R)
    WHT-ORN (2T)
    ORN-WHT (2R)
    WHT-GRN (3T)
    GRN-WHT (3R)
    WHT-BRN (4T)
    BRN-WHT (4R)
    80000 - 18
    4T
    3T
    2T
    1R
    1T
    2R
    3R
    4R
    1
    2
    3
    4
    5
    6
    7
    8
    Page OutMusic InRelay ContactsNo Connection
    The following products should help if you make your own cables:Suttle SE-266-8K 8 Position Modular Plug (requires an SE-166
    or SE-166-6 modular crimping tool).Hubbell BRFTP4P Snap-On 8 Position Modular Plug (does not
    require a special crimping tool).
    Check with your local supplier for other comparable products. 
    						
    							4-10
    MUSIC SOURCES
    Installing a Music Source (Figure 4-4)
    The CPU provides connection for a customer provided music
    source. Use this music source for Background Music and Music
    on Hold.To connect a music source:
    1. Find an available connector in a station cable and make sure
    it is correctly punched down at the 66M1-50 block.
    Follow standard color code order. Be sure the block is
    properly cross-connected.
    2. For the connector chosen, locate pins 2T and 2R (see Figure
    4-4) and connect the music source.
    3. Plug the modular jack into the CPU modular connector.
    Be sure the connected music source is compatible with the fol-
    lowing CPU music input specifications:
    Input Impedance: 10K Ohms
    Output Level: +18 dBr (+/- 2 dBr) @ 1.0 kHz
    Programming Background Music
    0201: Background Music
    Enter Y to enable Background Music system-wide. 1802: BGM
    Enter Y to enable Background Music at the extension.
    Programming Music on Hold
    0201: Music on Hold
    Enter Y to enable Music on Hold system-wide. 0201: MOH on Transfer
    Enter Y to enable Music on Hold for transferred calls. 
    						
    All NEC manuals Comments (0)