    							4. Optional
    Equipment
    4-11
    MUSIC SOURCES
    Figure 4-4  INSTALLING A MUSIC SOURCE
    RJ61X 
    Pin
    Latch
    faces upTo CPU
    Mod Jack
    Note
    reversalPort
    DesignationTo 66 Block
    WHT-BLU (1T)
    BLU-WHT (1R)
    WHT-ORN (2T)
    ORN-WHT (2R)
    WHT-GRN (3T)
    GRN-WHT (3R)
    WHT-BRN (4T)
    BRN-WHT (4R)
    80000 - 18A
    4T
    3T
    2T
    1R
    1T
    2R
    3R
    4R
    1
    2
    3
    4
    5
    6
    7
    8
    Page OutMusic InRelay ContactsNo Connection
    The following products should help if you make your own cables:Suttle SE-266-8K 8 Position Modular Plug (requires an SE-166
    or SE-166-6 modular crimping tool).Hubbell BRFTP4P Snap-On 8 Position Modular Plug (does not
    require a special crimping tool).
    Check with your local supplier for other comparable products. 
    						
    							4-12
    POWER FAILURE TELEPHONES
    Power Failure Cut-Through(Figure 4-5)
    When system AC power fails, the 8ATRU PCB automatically
    cuts through the first 2 trunk circuits to 2 Power Failure
    Telephone connections.To install Power Failure Cut-Through:
    1. Locate an available 8-pin jack in a trunk (A) block or station
    (B) block.
    Local codes may prevent you from using a DDK con-
    nector on the A block for optional equipment.
    2. For the 8-pin jack chosen, cross-connect the associated wire
    pair from the A or B block to the cross-connect block.
    3. Install a modular jack for each Power Failure Telephone
    within six feet of the telephone’s location.
    4. For each Power Failure Telephone, run one-pair of 24 AWG
    station cable from the cross-connect block to the telephone’s
    modular jack.
    5. Terminate the station cable WHT/BLU - BLU/WHT leads to
    the RED and GRN lugs in the modular jack.
    6. Install bridging clips as required.
    To test the Power Failure Telephone:
    1. Connect a Power Failure Telephone per Figure 4-5.
    2. Power down the system.
    3. At the Power Failure Telephone, lift the handset.
    You should hear dial tone on the trunk you connected
    in Figure 4-5.
    4. Place a test call.
    If power is restored while a cut-through call is in
    progress, the call is maintained until the user hangs up
    the Power Failure Cut-Through telephone. 
    						
    							4. Optional
    Equipment
    4-13
    POWER FAILURE TELEPHONES
    Figure 4-5  CONNECTING A POWER FAILURE TELEPHONE
    80000 - 40
    BLK YEL GRN RED
    To  P o w e r
    Failure
    Telephone
    connector on
    ATRU PCB
    Power
    Failure
    Telephone
    25 Pair
    Installation CableStation
    BlockCross
    Connect
    Block
    8-Pin
    Connector
    BLU-WHT WHT-BLU
    625
    Modular
    Jack One-Pair Cross-Connect 
    						
    							4-14
    DSS CONSOLE
    Installing a DSS Console(Figures 4-6 and 4-7)
    The DSS Console gives a keyset user a Busy Lamp Field (BLF)
    and one-button access to extensions, trunks and system features.
    Keep the following in mind when installing DSS Consoles:
    You can only connect 4 DSS Consoles.
    
    You can only connect DSS Consoles to Super Display or 34-
    Button Display telephones.
    
    A DSS Console does not require a separate station port – it
    connects directly to the keyset.
    To install a DSS Console:
    1. Turn the telephone upside down and remove the plastic filler
    plug from the DSS modular connector.
    2. Plug the DSS Console’s 8-pin modular line cord into the
    telephone’s DSS connector.
    3. Plug the other end of the 8-pin line cord into the DSS
    Console’s 8-pin jack.
    4. If you have a 24-Button DSS Console, attach the metal plate
    to both the DSS Console and telephone as shown.
    Programming DSS Consoles
    1801: DSS Type
    For the extension to which you have connected the DSS Console,
    enter 1 for 24-button, 2 for 110-button and 0 for unassigned.1801: DSS Block Number
    For the extension to which you have connected the DSS
    Console, enter the number of the block that corresponds to the
    connected console. A block is a unique DSS Console assign-
    ment. The system provides up to 4 blocks; one for each console.
    Your consoles can share the same block if you want
    them to have the same programming. They will still
    have unique Personal Speed Dial numbers, since a
    DSS Console uses the Personal Speed Dial for the
    extension to which it is attached.1704: DSS Console Key Assignment
    Program the DSS Consoles keys. Refer to the software manual
    for additional programming details. 
    						
    							4. Optional
    Equipment
    4-15
    DSS CONSOLE
    Figure 4-6  INSTALLING A 110-BUTTON DSS CONSOLE Figure 4-7  INSTALLING A 24-BUTTON DSS CONSOLE
    8
    0
    0
    0
    0
     
    -
     
    4
    7
    To 625 Modular Jack
    DSS Console Keyset
    80000 - 44A
    To 625 Modular Jack
    DSS Console Keyset 
    						
    							4-16
    2-OPX MODULE
    Installing the 2-OPX Module (Figure 4-8)
    The 2-OPX Module (P/N 92177A) provides two 2500 type ana-
    log circuits for connection to on-premise 2500 type single line
    devices (i.e., telephones, fax machines, modems, etc.) and to
    telco OL13B/C OPX circuits. It uses a single digital extension
    circuit for the power and signaling for both analog ports.To install a 2-OPX Module:
    1. Locate an 8-pin modular connector in a trunk block or sta-
    tion block.
    Local codes may prevent you from using a connector
    on the trunk block for optional equipment.
    2. For the connector chosen, cross-connect the associated wire
    pair from the trunk or station block to the cross-connect block.
    3. Install a modular jack for the 2 OPX Module within six feet
    of the module’s location.
    4. Run one-pair 24 AWG station cable from the cross-connect
    block to the modular jack.
    5. Terminate the station cable WHT/BLU - BLU/WHT leads to
    the RED and GRN lugs in the modular jack.
    6. Install bridging clips as required.7. Ground the 2-OPX Module by connecting a 12 AWG ground
    wire from the FG lug to a known earth ground.
    8. Plug a line cord into the 2-OPX unit and the 2-OPX’s modu-
    lar jack.
    The DS1 LED on the 2-OPX Module lights steadily.
    Programming 2-OPX Modules
    1801: Extension Circuit Type
    Assign the 2-OPX extension circuit type 21.
    The 2-OPX Module uses a single port.
    Notes:
    Each 2-OPX Module provides 2 OPX ports. The first 2-OPX
    extension number is the same as the port’s extension number.
    The second 2-OPX extension number is the first port plus
    201. For example, the two extension numbers for the 2-OPX
    Module plugged into extension 314 are 314 and 515.
    
    In fixed slot systems, the above is true only for a 2-OPX con-
    nected to the first DSTU PCB in the system. When connected
    to the second DSTU PCB in the system, the first 2-OPX
    extension number is still the same as the port’s extension num-
    ber, but the second 2-OPX extension number is the first port
    plus217. For example, the two extension numbers for the
    2-OPX Module plugged into extension 316 are 316 and 533. 
    						
    							4. Optional
    Equipment
    4-17
    2-OPX MODULE
    Figure 4-8  CONNECTING THE 2-OPX MODULE
    80000 - 41
    BLK YEL GRN RED
    To digital
    station
    circuit on
    DSTU PCB
    25 Pair
    Installation CableStation
    BlockCross
    Connect
    Block
    14 AWG to known
    Earth Ground
    8-Pin
    Connector
    BLU-WHT WHT-BLU
    625
    Modular
    Jack One-Pair Cross-Connect
    2-OPX Modular
    DS1
    F
    G 
    						
    							4-18
    2-OPX MODULE
    Wall Mounting the 2-OPX Module (Figure 4-9)
    1. Following the diagram below, move the screws that secure
    the 2-OPX Module cover from the outside holes to the inside
    holes. Do not tighten the screws.
    2. Attach the wall mount brackets to each side of 2-OPX
    Module and tighten the screws.
    3. With the connectors facing down, mount the 2-OPX Module
    to the wall using suitable customer-provided fasteners.
    Use the 2-OPX Module as its own mounting template.
    4. Connect the 2-OPX module as described on the previous page. 
    						
    							4. Optional
    Equipment
    4-19
    2-OPX MODULE80000 - 57
    Figure 4-9  WALL MOUNTING THE 2-OPX MODULE 
    						
    							4-20
    WALL-MOUNT KIT
    Installing the Wall-Mount Kit
    You can use a wall-mount kit to attach any key telephone to a
    wall. The wall-mount kit includes a mounting bracket, wall-
    mount screws and a handset hanger.
    Installing the Wall-Mount Handset Hanger (Figure 4-10)
    1. Remove the rubber plug that covers the slots for the handset
    hanger. Store the plug in a safe place.
    2. Insert the handset hanger in the slot provided beneath the
    telephone’s hookswitch.
    Figure 4-10  INSTALLING THE WALL-MOUNT HANGER
    80000 - 38 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Ds2000 Hardware Manual Instructions Manual