4. Optional Equipment 4-11 MUSIC SOURCES Figure 4-4 INSTALLING A MUSIC SOURCE RJ61X Pin Latch faces upTo CPU Mod Jack Note reversalPort DesignationTo 66 Block WHT-BLU (1T) BLU-WHT (1R) WHT-ORN (2T) ORN-WHT (2R) WHT-GRN (3T) GRN-WHT (3R) WHT-BRN (4T) BRN-WHT (4R) 80000 - 18A 4T 3T 2T 1R 1T 2R 3R 4R 1 2 3 4 5 6 7 8 Page OutMusic InRelay ContactsNo Connection The following products should help if you make your own cables:Suttle SE-266-8K 8 Position Modular Plug (requires an SE-166 or SE-166-6 modular crimping tool).Hubbell BRFTP4P Snap-On 8 Position Modular Plug (does not require a special crimping tool). Check with your local supplier for other comparable products.
4-12 POWER FAILURE TELEPHONES Power Failure Cut-Through(Figure 4-5) When system AC power fails, the 8ATRU PCB automatically cuts through the first 2 trunk circuits to 2 Power Failure Telephone connections.To install Power Failure Cut-Through: 1. Locate an available 8-pin jack in a trunk (A) block or station (B) block. Local codes may prevent you from using a DDK con- nector on the A block for optional equipment. 2. For the 8-pin jack chosen, cross-connect the associated wire pair from the A or B block to the cross-connect block. 3. Install a modular jack for each Power Failure Telephone within six feet of the telephone’s location. 4. For each Power Failure Telephone, run one-pair of 24 AWG station cable from the cross-connect block to the telephone’s modular jack. 5. Terminate the station cable WHT/BLU - BLU/WHT leads to the RED and GRN lugs in the modular jack. 6. Install bridging clips as required. To test the Power Failure Telephone: 1. Connect a Power Failure Telephone per Figure 4-5. 2. Power down the system. 3. At the Power Failure Telephone, lift the handset. You should hear dial tone on the trunk you connected in Figure 4-5. 4. Place a test call. If power is restored while a cut-through call is in progress, the call is maintained until the user hangs up the Power Failure Cut-Through telephone.
4. Optional Equipment 4-13 POWER FAILURE TELEPHONES Figure 4-5 CONNECTING A POWER FAILURE TELEPHONE 80000 - 40 BLK YEL GRN RED To P o w e r Failure Telephone connector on ATRU PCB Power Failure Telephone 25 Pair Installation CableStation BlockCross Connect Block 8-Pin Connector BLU-WHT WHT-BLU 625 Modular Jack One-Pair Cross-Connect
4-14 DSS CONSOLE Installing a DSS Console(Figures 4-6 and 4-7) The DSS Console gives a keyset user a Busy Lamp Field (BLF) and one-button access to extensions, trunks and system features. Keep the following in mind when installing DSS Consoles: You can only connect 4 DSS Consoles. You can only connect DSS Consoles to Super Display or 34- Button Display telephones. A DSS Console does not require a separate station port – it connects directly to the keyset. To install a DSS Console: 1. Turn the telephone upside down and remove the plastic filler plug from the DSS modular connector. 2. Plug the DSS Console’s 8-pin modular line cord into the telephone’s DSS connector. 3. Plug the other end of the 8-pin line cord into the DSS Console’s 8-pin jack. 4. If you have a 24-Button DSS Console, attach the metal plate to both the DSS Console and telephone as shown. Programming DSS Consoles 1801: DSS Type For the extension to which you have connected the DSS Console, enter 1 for 24-button, 2 for 110-button and 0 for unassigned.1801: DSS Block Number For the extension to which you have connected the DSS Console, enter the number of the block that corresponds to the connected console. A block is a unique DSS Console assign- ment. The system provides up to 4 blocks; one for each console. Your consoles can share the same block if you want them to have the same programming. They will still have unique Personal Speed Dial numbers, since a DSS Console uses the Personal Speed Dial for the extension to which it is attached.1704: DSS Console Key Assignment Program the DSS Consoles keys. Refer to the software manual for additional programming details.
4. Optional Equipment 4-15 DSS CONSOLE Figure 4-6 INSTALLING A 110-BUTTON DSS CONSOLE Figure 4-7 INSTALLING A 24-BUTTON DSS CONSOLE 8 0 0 0 0 - 4 7 To 625 Modular Jack DSS Console Keyset 80000 - 44A To 625 Modular Jack DSS Console Keyset
4-16 2-OPX MODULE Installing the 2-OPX Module (Figure 4-8) The 2-OPX Module (P/N 92177A) provides two 2500 type ana- log circuits for connection to on-premise 2500 type single line devices (i.e., telephones, fax machines, modems, etc.) and to telco OL13B/C OPX circuits. It uses a single digital extension circuit for the power and signaling for both analog ports.To install a 2-OPX Module: 1. Locate an 8-pin modular connector in a trunk block or sta- tion block. Local codes may prevent you from using a connector on the trunk block for optional equipment. 2. For the connector chosen, cross-connect the associated wire pair from the trunk or station block to the cross-connect block. 3. Install a modular jack for the 2 OPX Module within six feet of the module’s location. 4. Run one-pair 24 AWG station cable from the cross-connect block to the modular jack. 5. Terminate the station cable WHT/BLU - BLU/WHT leads to the RED and GRN lugs in the modular jack. 6. Install bridging clips as required.7. Ground the 2-OPX Module by connecting a 12 AWG ground wire from the FG lug to a known earth ground. 8. Plug a line cord into the 2-OPX unit and the 2-OPX’s modu- lar jack. The DS1 LED on the 2-OPX Module lights steadily. Programming 2-OPX Modules 1801: Extension Circuit Type Assign the 2-OPX extension circuit type 21. The 2-OPX Module uses a single port. Notes: Each 2-OPX Module provides 2 OPX ports. The first 2-OPX extension number is the same as the port’s extension number. The second 2-OPX extension number is the first port plus 201. For example, the two extension numbers for the 2-OPX Module plugged into extension 314 are 314 and 515. In fixed slot systems, the above is true only for a 2-OPX con- nected to the first DSTU PCB in the system. When connected to the second DSTU PCB in the system, the first 2-OPX extension number is still the same as the port’s extension num- ber, but the second 2-OPX extension number is the first port plus217. For example, the two extension numbers for the 2-OPX Module plugged into extension 316 are 316 and 533.
4. Optional Equipment 4-17 2-OPX MODULE Figure 4-8 CONNECTING THE 2-OPX MODULE 80000 - 41 BLK YEL GRN RED To digital station circuit on DSTU PCB 25 Pair Installation CableStation BlockCross Connect Block 14 AWG to known Earth Ground 8-Pin Connector BLU-WHT WHT-BLU 625 Modular Jack One-Pair Cross-Connect 2-OPX Modular DS1 F G
4-18 2-OPX MODULE Wall Mounting the 2-OPX Module (Figure 4-9) 1. Following the diagram below, move the screws that secure the 2-OPX Module cover from the outside holes to the inside holes. Do not tighten the screws. 2. Attach the wall mount brackets to each side of 2-OPX Module and tighten the screws. 3. With the connectors facing down, mount the 2-OPX Module to the wall using suitable customer-provided fasteners. Use the 2-OPX Module as its own mounting template. 4. Connect the 2-OPX module as described on the previous page.
4. Optional Equipment 4-19 2-OPX MODULE80000 - 57 Figure 4-9 WALL MOUNTING THE 2-OPX MODULE
4-20 WALL-MOUNT KIT Installing the Wall-Mount Kit You can use a wall-mount kit to attach any key telephone to a wall. The wall-mount kit includes a mounting bracket, wall- mount screws and a handset hanger. Installing the Wall-Mount Handset Hanger (Figure 4-10) 1. Remove the rubber plug that covers the slots for the handset hanger. Store the plug in a safe place. 2. Insert the handset hanger in the slot provided beneath the telephone’s hookswitch. Figure 4-10 INSTALLING THE WALL-MOUNT HANGER 80000 - 38