Page 71

ItWalling Peripheral Equipment 
Install a SUE/?C0NS0E lU00Attendant Console as a Maintenanca Console 
When you have completed Chart 6-3: 
l A SUPERCONSOLE 1000 Attendant Console will be installed as a maintenance 
console. 
l A printer will be connected to it (optional). 
Note: A Digital Line Card (seated in a high-power slot) is required to support a SlJPfRCONSOLE 7000 
Attendant Console used as a maintenance console. There is no console jack on the cabinet. 
Chart 6-3 Install a SUPERCONSOLE 7000...

Page 72

Installation Information 
Install a System Printer 
6.3 When you have completed Chart 6-4: 
l The system printer will be connected to the control cabinet. 
l The system printer will be powered up. 
Chart 6-4 install a System Printer 
Step Action Comments 
Connect System Printer 
1. Connect one end of a standard 25pin RS-232 cable 
to the RS-232 port of the printer (or similar output 
device). 
2. Connect the other end of the 25-pin RS-232 cable to J8 printer pins 6, 8, and 20 are t,ied 
a 25to-9 pin...

Page 73

Installing Peripheral Equipment 
Install Night Bell 
6.4 Chart 6-5 describes the procedure for installing a Direct Connect night bell, and Chart 
6-6 describes the procedure for an Auxiliary Relay night bell. When you have 
completed Chart 6-5 or Chart 6-6: 
l The DTMF receiver/relay module will be installed. 
l The night bell will be installed and connected. 
Note: 1. incoming and internal calls can be directed to a common alerting device (bell). The bell is 
activated by a relay on the DTMF...

Page 74

Installation Information 
r 
itep 
1. 
2. 
3. 
4. 
5. 
6. Chart 6-6 Install Night Bell (Auxiliary Relay) 
Action Comments 
Install DTMF Receiver/Relay module 
Ensure that the DTMF receiver/relay module is in- 
stalled on the Universal Card. 
Install Bell 
Follow manufacturer’s instructions to install the bell. Install equipment in the environment 
specified by the manufacturer. 
Connect Auxiliary Relay 
Connect one side of the auxiliary relay coil through 
the cross-connect field to the customer supplied...

Page 75

Installing Peripheral Equipment 
Install Paging Equipment 
6.5 The Paging equipment connections are illustrated in Figure 6-l. When you have 
completed Chart 6-7: 
. The Music-on-Hold/Paging module or unit will be installed. 
l The paging equipment will be installed. 
. The paging equipment will be connected. 
Note: 1. The paging equipment is customer-supplied. 
2. The PABX supports up to nine separate paging zones. Each zone requires a paging module 
or a DMP. 
Chart 6-7 install Paging Equipment 
Step...

Page 76

Installation Information 
Install Music-On-Hold Equipment 
6.6 The Music-on-Hold equipment connections are illustrated in Figure 6-l. When you 
have completed Chart 6-8: 
. The Music-on-Hold/Paging module/unit will be installed. 
l The Music source will be installed and connected. 
Note: 1. An external music source can be connected to the system using a Music-on-Hold/Paging 
module on the Universal Card or by using the Music-on-Hold/Pager unit (DMP). Music on 
Hold is used with the camp-on and hold...

Page 77

Installing Peripheral Equipment 
Install Alternate Music Source for ACD 
’ 6.7 When you have completed Chart 6-9: 
l The alternate music source for Automatic Call Distribution (ACD) will be installed. 
Note: 1. An alternate music source for the ACD feature package must be either: 
- an FCC Par-l 68- and Industry Canada approved recorded announcement device connect- 
ed to an on-premises (ONS) Line Card circuit or 
- any other source which is connected through an FCC Part 68- and industry Canada-...

Page 78

Installation information 
6-14 Issue 1 Revision 0 March 1997  

Page 79

7 Cabling and Cross 
Connections : 
System Cabling 
7.1 This section gives the Tip-Ring Assignment tables for cabling and crossconnecting 
the PABX. Table 7-i lists these tables. 
Table 7-l Cable Terminations 
Contents 
Table 7-2 Tip and Ring Assignments for High-power Slots 
J5 and J9 f 
Table 7-3 Tip and Ring Assignments for Universal Card Modules 
J5 and J9 
I 
Table 7-4 
Tip and Ring Assignments for Low-power Slots 
J7 and Jll 
Table 7-5 
1 USOC Connector Pin Designations 
March 1997 Issue 1 Revision...

Page 80

Installation Information 
Table 7-2 Digital Bay Tip and Ring Assignments (High-power Slots) 
, 
J5 and J9 for Digital Bay 1 
Lead Designation 
Slot Plug Pin Pair Cct ONS or Cct LS/GS Cct COV Cct OPS or 
DLC DID 
26 W-BL 1 Tl 1 Tl 1 Tl 1 Tl 
1 BL-W Rl Rl Rl Rl 
27 W-O 2 T2 MM1 2 T2 
2 
o-w R2 Ml R2 
28 W-G 3 T3 2 T2 3 T3 2 T2 
6 J5 3 G-W R3 R2 
R3 R2 
or 29 W-BR 4 T4 MM2 4 T4 
8 J9 4 BR-W R4 M2 R4 
30 W-S 5 T5 3 T3 5 T5 
3 T3 
5 s-w R5 R3 R5 R3 
31 R-BL 6 T6 MM3 6 T6 
6 BL-R 
R6 M3 R6 
32 R-O 7 T7 4 T4 4...