Page 51

Install Digital Peripheral Cards / Modules 
Chart 4-l Install Universal Card and Modules (continued) 
Step Action Comments 
Install E&M Trunk Module 
Typical installation is shown in Figure 4-2. 
10. Set the eight DIP switches for the type of trunk in Shown in Table 4-2. 
use. 
11. Insert the trunk module (optional) in its assigned Interfaces to Type 1 and Type 5 E&M 
location. trunks. 
12. Press the module until it snaps into its standoffs. 
Make sure that connectors are properly seated. 
Install...

Page 52

Installation Information 
Figure 4-2 Installation of Module on Universal Card 
Table 4-l Music-on-Hold/Paging Module Specifications 
I Music-on-Hold Input 
I input impedance 
I 600 ohms 
I 
Paging Output input level 
-6 dBm 
output impedance (low) 200 ohms 
1 output level into 600 ohms 1 -6 dBm 
Relay Contact maximums 
90 V rms at 0.1 A 
48 V dc at 0.5 A 
Table 4-2 E&M Trunk Module Switch Settings 
Function 
Switches 
1 2 3 4 5 6 7 8 
PA8X to line Gain 
3 dB 0 X X x x x x x 
-13 dB 1 X x x x x X X 
Page...

Page 53

Install Digital Peripheral Cards / Modules 
Table 4-2 E&M Trunk Module Switch Settings (continued) 
Line to PABX Gain 
-4 dB X 0 X X X X X 
X 
-1ldB X 1 X X x x x x 
Termination 
600 ohm X X 1 0 X X X X 
Complex X X 0 
1 X 
x x x 
Transmission 
2-wire X X X x ‘I x x x 
4-wire X x x x 0 x x x 
Signaling ~ 
Vw 1 X x x x X 
1 X X 
Vw 5 X x x x X 
0 x x 
Page 2 of 2 
0 = open, I = closed, X = not applicable 
Install Line (ONS, OPS, COV, and Digital) and DID Trunk Cards 
4.2 Chart 4-2 applies to the ONS, OPS,...

Page 54

lns~alla~ion Information 
WARNING: 
ANY CONNECTION OF AN ONS OR DIGITAL LINE CARD TO AN OFF-PREMISE 
APPLICATION, AN OUT-OF-PLANT APPLICATION OR ANY OTHER EXPOSED 
PLANT APPLICATION MAY RESULT IN A SAFETY HAZARD AND/OR DEFECTIVE 
OPERATION AND/OR EQUIPMENT DAMAGE. 
Chart 4-2 Install Line or DID Trunk Cards 
Step Action Commenb 
Follow General Procedures 
1. Follow the general procedures for handling circuit 
cards. 
Unpack and Inspect 
2. Wearing the antistatic wrist strap, unpack and 
inspect the line...

Page 55

Install Digital Peripheral Cards / Modules 
Chart 4-3 Install LWGS Trunk Card (continued) 
Step Action 
Comments 
2. Identify trunk circuits by bay, slot, circuit and type 
(loopstart or groundstat-t). This is available from the configuration 
information prepared by the customer 
service representative. 
Unpack and inspect 
3. Wearing the antistatic wrist strap, unpack and 
inspect the LS/GS Trunk Card and jumpers. Repack and return any damaged or 
incorrect items. 
Set LWGS Trunk Card Jumpers 
4. Set...

Page 56

Installation Information 
Install a Tl-DSI Trunk Card and Tl Trunk Adapter 
4.4 The PABX uses an adapter with a straight-out Ti connector. 
Note: 1. The Tl -DSl Trunk Card interfaces to a single Tl trunk circuit. 
2. The Tl Trunk Card kit includes: 
- Tl -DSl Trunk Card 
- Ti Trunk Adapter assembly 
- hardware kit 
3. The hardware kit contains parts to accommodate manufacturing variants; all the hardware 
parts will not be used in any particular installation. 
WARNING: INCORRECT INSTALLATION MAY RESULT...

Page 57

Install Digital Peripheral Cards / Modules 
Chart 4-4 Install a Tl-DSl Trunk Card and Adapter Assembly (continued) 
Step Action Comments 
5. Plug the Tl Trunk Adapter Assembly connector into 
Refer to Figure 4-4 and Figure 4-5. 
the backplate connector. Align the 4 screw holes on 
the housing with holes (or standoffs) on backplate. 
Fasten using 4 screws and washers from kit. 
Install Tl-DSI Trunk Card(s) 
6. Insert the Tl -DSl trunk card in a high power slot. 
First Tl card goes in slot 6. 
Install Tl...

Page 58

Installation Information 
VERY SHORT STANDOFFS (4) 
Tl TRUNK CABLE 
TO CHANNEL SERVICE UNIT 
se .w’ ~ , BACKP!-ANE 
. . . . . @....Q  . . 
..’ 
..’ 
,..’ /’ 
. . ‘. 
,....’ 
Tl TRUNK ADAPTER ASSEMBLY 
NOTI? A Tl ADAPTER CABLE ASSEMBLY IS NOT USED 
cc0534 
4-10 
Figure 4-5 Install a Dual Tl Trunk Adapter Assembly on an SX-ZOO PABX 
Issue 1 Revision 0 March 1997  

Page 59

5 Bring System into Service 
Connect Cables Between PABX and Cross-Connect Field 
5.1 When you have completed Chart 5-l : 
l Connection blocks will be installed. 
l Cables will be connected at the connection blocks. 
l Cables will be run from the cross-connect field to the cabinet(s). 
l Cable connectors will be attached to the cabinet plugs. 
l Cables will be connected at the cross-connect field. 
Chart 5-l Connect Cables Between PABX and Cross-Connect Field 
Step Action Comments 
Install Connection...

Page 60

Installation information 
CONNECTOR TO BACKPLANE 
ERRITE, CASE OPEN 
cc0145 
Figure 5-l Ferrite Installed on a Cable 
Install System ID Moduleand PCMCIA Memory Card onto the Main Control Card II 
5.2 When you have completed Chart 5-2 
. The System ID module will be installed onto the MCC Il. 
l The PCMCIA Memory Card will be installed onto the MCC Il. 
CAUTION: Remove conductive articles such as rings and watches before 
handling the Main Control Card Il. 
Do not use a screwdriver or any similar object...