Mitel SX 200 ML PABX Instructions Guide
Here you can view all the pages of manual Mitel SX 200 ML PABX Instructions Guide. The Mitel manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 491
Circuit Card Descriptions SET FOR L,OOP START SET FOR GROUND START LEDs cc0113 Figure 5-5 Loop Start/Ground Start Card and Jumper Settings ONS Line Card WARNING: ANY CONNECTION OF THIS CARD TO AN OFF PREMISE APPLICATION, AN OUT OF PLANT APPLICATION, OR TO ANY OTHER EXPOSED PLANT APPLICATION MAY RESULT IN A SAFETY HAZARD, AND/OR DEFECTIVE OPERATION, AND/ OR EQUIPMENT DAMAGE. Brief Description 5.7 The On-Premises (ONS) Line Card, part number 9109-010-00X, interfaces standard subscriber...
Page 492
Engineering Information Facilities Each line circuit provides the following facilities: l Line protection l Analog-to-Digital / Digital-to-Analog conversion (u-law) l Line circuit status monitoring l Signaling (ringing, message waiting). Electrical Description The following description applies to each line circuit. Tip and Ring are each protected against transients by a 200 volt varistor to ground. A bridge rectifier provides four protection diodes for the line circuit transistors. The -28...
Page 493
Circuit Card Descriptions building that houses the PABX and the line may be exposed to extraneous high volt- ages or induced currents (e.g., lightning). The OPS Line Card can be used in any digital high-power (upper) slot. The maximum number of these cards is four per bay, providing a maximum of 24 ports per bay. The card is 157.5 mm high x 366.4 mm long (6.2 in. x 14.4 in.). Major Components Major components for the OPS Line Card are: l Mite1 8962 FilterKodec (six) l 2-wire / 4-wire converter...
Page 494
Engineering Information The line circuit applies ringing voltage to the appropriate line through a relay and removes it when the telephone is answered. Answer is detected by monitoring the loop current. Loop current is provided through a pair of 200 ohm resistors. Below 900 ohms loop resistance, active current limiting circuitry limits line power to less than 1.5 watts. Ringing for each line is controlled by relay 2. Condition I Relay 1 Relay 2 Idle or Talk I OFF I OFF I Ringing OFF ON...
Page 495
Circuit Card Descriptions Facilities Each Digital Network Interface Circuit (DNIC) provides the following facilities: l Line protection l Full duplex simultaneous data and voice digital transmission over a single pair of wire . Line circuit status monitoring 9 Signaling and HDLC protocol to its associated DATASET. Electrical Description Each Digital Network Interface Circuit (DNIC) connects one of the devices listed in paragraph 5.9 to the common circuitry on the DLC card (and then to the...
Page 496
Engineering Information Loop Length Specifications for Connections to a Digital Line Card The following rules for loop lengths between the Digital Line Card within the PABX and the SUR!3SE~telephones, or SU/?!!F?CO/VSO~~ 7000 Attendant Console must be followed for proper operation of the device: Maximum loop length (twisted pair) 24 or 26 AWG see Table Maximum length of quad cable (22 AWG) 50 m (16Oft) Modular Line Cord 3 m (loft) Telephone, Module, or Console I n n n I I I-l LI 24 or 26...
Page 497
Circuit Card Descriptions General Description The Ti interface will transmit and receive 24 &bit voice/data channels on a 4-wire digital trunk that operates at I.544 Mb/s. The BCC performs all control functions. To provide signaling information on the Tl line, data bits are “stolen” from each channel to provide channel associated signaling. The Ti Trunk Card includes a phase comparator which, through the Tl Clock on the Main Control Card II, keeps the system clock in phase with the incoming frame...
Page 498
Engineering Information phase count value constant over a longer term (I 6 seconds). The Tl circuit data buffer accommodates short-term phase variation (jitter). Indicators If any of the data channels on the Ti link are active, the upper front panel LED lights, giving visual indication of channel activity. If the PABX is receiving a yellow alarm condition, the yellow (NO SYNC) LED lights. If transmitting a yellow alarm condition, and not receiving a yellow alarm condition, then the LED is off....
Page 499
Circuit Card Descriptions . Line protection circuits . Line status LEDs - one per line l Card status LED - one. Facilities Facilities provided by the COV Line Card include: l Amplitude Shift Keyed communication l Analog/Digital and Digital/Analog conversions (p-law) l Battery Feed to power telephones. Electrical Description Control information from the backplane is converted to a 32 kHz amplitude shift-keyed (ASK) data stream. The audio information is taken from the 2 Mb/s data link, converted...
Page 500
Engineering Information distribution frame. A single LED indicator provides basic status information. The unit can be wail-mounted next to the SX-20CJ ML PABX. Each Music-on-Hold/Pager Unit supports asingle paging zone. If more than one paging zone is required, then additional Music-on-Hold/Pager Units can be added as required. STATUS LED INTERFACE CONNECTOR EEOZO3 Figure 5-6 Music-on-Hold/Pager Unit LED indicator The LED indicates the following states: Table 5-l Music-on-Hold/Pager Unit LED...