Loss and Level Plan 
Table 8-3 Conferencing Loss Plan (continued) 
Originating Circuit Connecting Circuit Loss (ctB) TX Direction Loss (dB) Rx 
Direction 
Dl-l- -3.0 -9.0 
sATT -3.0 -3.0 
sDTT -3.0 -3.0 
SCTT -3.0 -9.0 
sATT -3.2 -3.2 
sDTT -3.2 -3.2 
SCTT -3.2 -9.2 
ONS(D) -6.0 -6.0 
OPSS OPSS -6.0 -6.0 
OPSL -3.0 -3.0 
ACO(D) -4.0 -4.0 
AJ-W’I -5.0 -5.0 
ATO( D) -6.0 -6.0 
DC0 -3.0 -3.0 
DTO -3.0 -9.0 
DlT -3.0 -9.0 
sATT -3.0 -3.0 
SD-IT -3.0 -3.0 
SC-l-r -3.0 -9.0 
ONS(D) -3.0 -3.0 
OPSL OPSL 0 0...

Page 522

Engineering Information 
Table 8-3 Conferencing Loss Plan (continued) 
Originating Circuit 
AT-WI 
ATO 
sATT Connecting Circuit Loss (d6) TX Direction Loss (dB) Rx 
Direction 
ATO( D) -4.0 -4.0 
DC0 -1 .o -1 .o 
DTO -1 .o -7.0 
D-i-r -1 .o -7.0 
sATT -1 .o -1 .o 
SDTT -1 .o -1 .o 
scl-r -1 .o -7.ci 
ONS(D) -5.0 -5.0 
OPSS -5.0 -5.0 
OPSL -2.0 -2.0 
AT-W) -4.0 -4.0 
ACO( D) -3.0 -3.0 
ATO( D) -5.0 -5.0 
DC0 -2.0 -2.0 
DTO -2.0 -8.0 
D-l-r -2.0 -8.0 
sATT -2.0 -2.0 
sDTT -2.0 -2.0 
SCTT -2.0 -8.0 
ONS(D)...

Page 523

Loss and Level Plan 
Table 8-3 Conferencing Loss Plan (continued) 
Originating Circuit 
Connecting Circuit Loss (dB) TX Direction 
Loss (dB) Rx 
Direction 
ATO( D) -3.0 -3.0 
DC0 0 0 
DTO 0 -6.0 
Dll- 0 -6.0 
sA-IT 0 0 
sDTT 0 0 
SCTT 0 -6.0 
ONS(D) -3.0 -3.0 
sDTT OPSS -3.0 -3.0 
OPSL 0 0 
ACO(D) -1 .o -1 .o 
A-WV -2.0 -2.0 
ATO( D) -3.0 -3.0 
DC0 0 0 
DTO 0 -6.0 
Dll- 0 -6.0 
sATT 0 0 
sDTT 0 0 
SCTT -6-O -6.0 
ONS(D) -9,o -3.0 
SC-i-r OPSS -9.0 -3.0 
OPSL -6.0 0 
ACO(D) -7,o -1 .o 
AT(D) -8.0 -2.0...

Page 524

Engineering Information 
Table 8-3 Conferencing Loss Plan (continued) 
Originating Circuit 
Connecting Circuit Loss (dB) TX Direction Loss (dB) Rx 
Direction 
ATO( D) -3.0 -3.0 
DC0 0 0 
DTO 0 -6.0 
D-IT 0 -6.0 
sAll- 0 0 
sDTT 0 0 
SCTT 0 -6.0 
ONS(D) -9.0 -3.0 
D-I-0 OPSS -9.0 -3.0 
OPSL -6.0 0 
ACO(D) -7.0 -1 .o 
AJ-W) -8.0 -2.0 
ATO( D) -9.0 -3.0 
DC0 -6.0 0 
DTO -6.0 -6.0 
D-I-F -6.0 -6.0 
sA-IT -6.0 0 
sDTT -6.0 0 
SC-l-r -6.0 -6.0 
ONS(D) -9.0 -3.0 
D-i-r OPSS -9.0 -3.0 
OPSL -6.0 0 
ACO(D) -7.0...

Page 525

Loss and Level Plan 
Tone Levels 
8.4 All of the tones used by the PABX are provided by the Digital Signal Processor on the 
Main Control Card. The system provides eight tone channels, each of which can 
generate either a dual or single frequency tone. One channel is used to generate a 
signal which controls the frequency and amplitude of the ringing generator output. 
Three channels are used for DTMF tone generation, and the remaining four are used 
to generate the system call progress tones. 
Most call...

Page 526

Engineering Information 
8-16 Issue 1 
Revision 0 March 1997  

Page 527

9 Call Progress Tones and 
Ringing Cadences 
This Part describes the different call progress tones and ringing cadences that are 
available to support PABX requirements. 
North America 
Tone Plan 
9.1 Table 9-l identifies the tones that are generated by the PABX in North America. 
Table 9-l North America Tone Generation Table 
Tone Frequency 1 Frequency 2 Level With No Interface 
Gain/Loss 
Ringing 20 Hz --- 
90 Vrms 
Dial tone 
350 Hz 440 Hz -10.75 dBm0 
Busy tone 
480 Hz 620 Hz -20.00 dBm0 
Ringback...

Page 528

Engineering Information 
Table 9-2 North America Digital Bay Ringer Caclencing 
Discriminating Ring (Option 17) enabled and Discriminating Ring Always (Option 18) disabled 
ONS/OPS 
Internal (standard) 
.9 on 3.1 off 
repeating 
Mexico 
ONS/OPS 
External 
(discriminating) 
.350 on .200 off 
.350 on 3.1 off 
repeating SUPERSET 
Telephones 
Internal (standard) 
1 on 3 off 
repeating SUPERSET 
Telephones 
External 
(discriminating) 
.400 on .200 off 
.400 on 3.0 off 
repeating 
Tone Plan 
9.2 
Table 9-3...

Page 529

Call Progress Tones and Ringing Cadences 
Ringer Cadencing 
Table 9-4 identifies the ringer cadencing that is provided by the PABX in Mexico. 
Table 9-4 Mexico Digital Bay Ringer Cadencing 
Discriminating Ring (Option 17) enabled and Discriminating Ring Always (Option 18) disabled 
ONS/OPS ONS/OPS SUPERSET SUPERSET 
Internal (standard) External Telephones Telephones 
(discriminating) Internal (standard) External 
(discriminating) 
.9 on 4.1 off .350 on .200 off 1 on 4 off 
.400 on .200 off 
repeating...

Page 530

Engineering Information 
Ringer Cadencing 
Table 9-6 identifies the ringer cadencing that is provided by the PABX in Hong Kong 
and Taiwan. 
Table 9-6 Hong Kong / Taiwan Digital Bay Ringer Cadencing 
Discriminating Ring (Option 17) enabled and Discriminating Ring Always (Option 18) disabled 
ONS/OPS 
internal (standard) 
.9 on 3.1 off 
repeating 
Malaysia 
ONWOPS 
External 
(discriminating) 
.350 on .200 off 
.350 on 3.1 off 
repeating SUPERSET 
Telephones 
Internal (standard) 
1 on 3 off 