Page 481
Circuit Card Descriptions purchased options for the PABX. If the System ID module is missing or the Mite1 options password is incorrect, the PABX does not operate. SYSTEM ID MODULE Jl CONNECTOR PI J2 CONNECTOR TO SFT TO BCC AND PORTS CC0567 Figure 5-l Main Control Card II Bay Control Card Brief Description 5.3 The Bay Control Card (BCC), part number 9109-017-000, is required in the lower rightmost slot. CAUTION: This card must not be inserted or removed with the power on. Functions The...
Page 482
Engineering InformaKon Electrical Description Connection to the Main Control Card II is via one 96 DIN connector on the Bay Control Card. There are two pairs of switches on the card; see Figure 5-2. All four switches must be set to closed for normal operation. r Ll~~m - &Ii.L.-- n- -- - CPU I L-III Figure 5-2 Bay Control Card 5-4 Issue 1 Revision 0 March 1997
Page 483
Circuit Card Descriptions @ MllW MODULE ’ e MODULE $ * 0: 1 2 MODULE MODULE g INDICATORS 3 e= MODULE 4 0 id v ALARM - ALARM LED Jl UNIVERSAL @ MllEL- LINE I 0 LINE2 08 LINE3 0: LINE4 @g F LINE 5 0 LINE LINE6 0 INDICATORS LINE7 & LINE8 @ LINE9 @ LINE IO@ LINE II@ LINE 120 r q v ALARM- AL4RM WI LED l @ Mm TRUNK@ 1 2 TRUNK@z 2 u TRUNK 0 3 m TRUNK@$ 4 TRUNK 0 5 TRUNK @ 6 ONS LSIGS CARD LINE CARD OPS LINE INDICATORS - ALARM - LED @ MI-EL- TRUNK 0 g 1...
Page 484
Engineering Information Universal Card . . Brief Description 5.4 The Universal Card, part number 9109-005-000, interfaces up to four modules to the backplane. The card modules are illustrated in Figure 5-4. Facilities Facilities provided by the Universal Card include: . module mounting positions (four) l module activity LEDs (four) l software-controlled failure alarm LED. Physical Description A module measures 145 mm x 83 mm (5.7 in. x 3.25 in.). Each module has two vertical 32-pin female...
Page 485
Circuit Card Descriptions - SWITCH MUSIC ON HOLD/PAGER MODULE RECEIVER/RELAY E&M TRUNK MODULE UNIVERSAL CARD LED’s 1 2 I MODULE 1 e MODULE 2 J I MODULE 3 v MODULE 4 -ALARM Figure 5-4 Universal Card and Modules DTMF Receiver/Flelay Module Brief Description The DTMF Receiver/Relay Module facilitates the reception and decoding of DTMF dialing. Main Components Major components of the DTMF Receiver/Relay Module are: l Mite1 filterkodec (four) l Mite1 8870 DTMF receiver (four) l...
Page 486
EnQineerinQ InfcmnUtiOn 5-8 l Guard time circuit 9 Presentation of digits on parallel bus with Data Valid signal. Circuit Description There are four receivers on the DTMF module. Each receiver takes its input from the incoming serial PCM audio stream and repeats this data to the outgoing serial PCM stream approximately 125 msec later. A filter/codec converts the data to analog audio which is monitored by a DTMF Receiver chip. When DTMF tones are detected, the loopback of the data to the PCM...
Page 487
Circuit Card Descriptions Function Switches 12345678 PABX to Line Gain 3 dB 0 x x x x x x x -13 dB lxxxxxxx Line to PABX Gain- 4 dB xoxxxxxx -1-I dB X lxxxxxx Balance 600 ohm x x 10xXxX Complex x x Olxxxx Transmission 2-wire x x x x I x x x 4-wire x x x x 0 x x x Signaling Vw 1 x x x x x 1 x x Vw 5 x x x x x 0 x x 0= open, I= closed, x= not applicable Default setting for North America is 001 Oil 00 The E&M Trunk Module applies signals to the M lead and monitors the E lead. In the...
Page 488
Engineering Information The control relay contacts are rated as follows: maximum switching voltage 90 Vrms maximum carrying current 0.4 Arms Note: This relay contact may be connected only to a secondary circuit that has no direct connection to a primary circuit, and receives its power from a transformer, converter, or equivalent isolation device situated within the equipment. DID Trunk Card Brief Description 5.5 The DID Trunk Card (pat? number 9109-031-000) contains six l-way direct inward dial...
Page 489
Circuit Card Descriptions line. Ring is grounded and Tip is at -48 Volts. There are two types of controlled address signaling: Delay Dial and Wink Start. A Delay Dial signal must start no later than 150 ms after trunk seizure. It is held until the PABX is ready to receive dialing. Minimum hold time is 140 ms. A Wink Start signal must start at least 100 ms after trunk seizure. It is sent when the PABX is ready to receive dialing and can be held a maximum of 290 ms. Where the CO does not provide...
Page 490
Engineering Information Facilities 5-12 Facilities provided by the L!YGS Trunk Card include: l Loop Start or Ground Start selectable by jumper l M and MM signaling leads available l Trunk activity indicated by LED (one per trunk) l Transient suppression on Tip, Ring, and signaling leads l Alarm LED. Electrical Description The Loop Start/Ground Start Trunk Card mounts in any slot and interfaces six trunk circuits to the system. Each trunk circuit is programmed as loop start or ground start by...