DATASET 2 100 Series Description 
Terminate B channel command, which it can do because the D channel is active while 
the B channel session is in progress. 
Data is clocked to and from the shift registers at a constant rate by the synchronous 
clocks on the PI.5232 interface. The data set firmware converts this data into packets 
which are passed through the PABX in Ul frames. No error detection or correction is 
performed on this data; synchronous data usually includes its own error detection and...

Page 442

Peripheral Devices 
Timing Modes 
10.6 There are four modes of timing available with a DATASET 2100 series that are used 
according to the current mode of operation. 
Internal - The Internal clock is used when the DATASET 2100 Series is operating in 
Data Communication Equipment (DCE) mode. The transmit clock (SCT) to the Data 
Terminal Equipment (DTE) is generated within the dataset’s baud rate generator and 
is not synchronized with PABX timing. The dataset’s receive clock (SCR) to the DTE 
is...

Page 443

DATASET 2 100 Series Description 
Table 10-l DATASET 2100 Dip Switch Settings 
SWITCH 1 
DATASET OPERATING MODE 
DOWN 
SET - PABX OPERATION 
UP UP 
DOWN DOWN DOWN 
UP DOWN 200 
DOWN 300 
, 
, 
UP 1 DOWN 1 UP 
1 DOWN 1 600 
DOWN 
UP UP 
UP UP 
UP DOWN 1200 
DOWN 2400 
1 DOWN 1 DOWN 1 DOWN 1 UP 1 4800 
I 
UP 
DOWN DOWN 
UP DOWN 
UP 9600 
DOWN UP 19200 
SYNCHRONOUS MODE 
SWITCH 3 SWITCH 4 
DOWN DOWN 
DOWN UP 
UP DOWN 
UP UP SYNC OPERATING MODE 
INTERNAL CLOCK 
SYSTEM CLOCK 
TX EXTERNAL CLOCK 
TX AND RX...

Page 444

Peripheral Devices 
Table 1 O-l DATASET 2100 Dip Switch Settings (continued) 
Note: 
1. PARAMETER CHANGES MUST BE FOLLOWED BY A POWER RESET. 
2. ALL 
SWITCH PARAMETERS, EXCEPT SWITCH 1 CAN BE OVERRIDDEN BY THE PABX 
CDE PARAMETERS. 
1 O-6 
Issue 1 Revision 0 March 1997  

Page 445

DATASET 2 100 Series Description 
Standalone DATASET 2103 Description 
10.9 A Standalone DATASET 2103 is packaged in a fiat case which can be placed under 
a standard desk telephone set. It is functionally the same as the Rack Mounted 
DATASET 2102 (they share the same base printed circuit board). The Standalone 
DATASET 2103 can be connected to the PABX using a four-wire connection; two 
wires connect the dataset to the Digital Line Card, and two different wires connect the 
telephone set Tip-Ring pair...

Page 446

Peripheral Devices 
Installation 
WARNING: ANY CONNECTION OF THIS SET TO AN OFF PREMISE APPLICATION, AN OUT 
OF PLANT APPLICATION, OR TO ANY OTHER EXPOSED PLANT APPLICATION 
MAY RESULT IN A SAFETY HAZARD, AND/OR DEFECTIVE OPERATION, AND/OR 
EQUIPMENT DAMAGE. 
Chart 10-l Installation of a Standalone DATASET 2103 
Step 
Action 
1. Install a Standalone DATASET 2103 by placing it near its associated telephone set and data 
peripheral (its case is designed to lie flat on the desk under a standard telephone)....

Page 447

DATASET 2 100 Series Description 
STANDARD TELEPHONE 
ERMINAL OR PC DATASET 2103 
STANDARD TELEPHONE 
DATASET 2103 
cc0559 
Figure 1 O-l Typical Standalone DATASET 2103 Applications 
March 1997 
Issue 1 
Revision 0 1 o-9  

Page 448

Peripheral Devices 
MODE 
SWITCHES 
DISCONNECT KEY 
ATTENTION KEY 
EEOOi3 
Figure 1 O-2 Standalone DATASET 2103, Showing Connectors and Indicators 
10-10 
Issue 1 
Revision 0 
March 1997  

Page 449

DATASET 2100 Series Description 
Circuit Description 
10.10 The DATASET 2100 Series circuit contains six basic blocks, as shown in Figure 10-3. 
The microcontroller is the central processor for the dataset; it contains two timers, the 
BAUD rate generator, the Universal Asynchronous Receiver Transmitter (UART) and 
the system High-level Data Link Control (HDLC). The switches on the data set inter- 
face directly to the microcontroller; this way, the firmware can override the switch 
settings. 
The...

Page 450

Peripheral Devices 
RS-232 CONTROL LEADS 
/ 
-t RxD w RS-232 
H INTERFACE 
ADDRESS 
SERIAL/PARALLEL e 
DATA 
CONVERTER 
A 
DNIC 
* INTERFACE 
MICRO 
CONTROLLER 
PHASE 
LOCK, 
LOOP AND 
CLOCK 
MASTER 
CLOCK 7 
l SWITCHES +I2 
-12 POWER 
El SUPPLY 
+5 
CC0081 
10-12 
Figure IO-3 Typical DATASET 2100 Series Block Diagram 
Issue 1 Revision 0 March 1997  