Page 131

Programming
121
Programming
3. Enter valid Bay, Slot and Circuit numbers for the first trunk and press 
the ENTER softkey. 
The system displays: TO BAY: SLOT: CIRCUIT:. 
4. Enter valid Bay, Slot and Circuit numbers for the last trunk and press 
the ENTER softkey. 
5. The system copies the values from the first trunk to all the trunks 
specified in the range.
Programming a DISA Trunk
1. Form 01, System Configuration
Program a trunk card that meets the trunk type requirements.
2. Form 13, Trunk Circuit...

Page 132

Technician’s Handbook
122
Form 33: Enter appropriate DISA access codes.
Programming ANI/DNIS on an
Incoming Trunk
ANI (Automatic Number Identification) - the local carrier sends to the 
PBX the phone number of the calling party.
DNIS (Dialed Number Identification Service) - the local carrier sends to 
the PBX the digits dialed by the calling party. 
ANI/DNIS is available only to incoming trunks with trunk descriptor 
“T1-E&M” and “T1-DID/TIE”, which accept DTMF signaling and have 
the wink timer active....

Page 133

Programming
123
Programming
Wink Timer to 100-350 for MCI 
and 140-290 for US SPRINT 
Debounce Timer to 100 ms or greater.
3. To define which information will be displayed on the sets, ANI, 
DNIS, both, or none (standard trunk label display), select the 
required following COS options:
COS Option 502 - Display ANI/DNIS Information = ENABLE / 
DISABLE
COS Option 613 - Display ANI Information Only = ENABLE / 
DISABLE
COS Option 503 - Display CLASS Name if required.
4. To display ANI and DNIS digits on...

Page 134

Technician’s Handbook
124
Table 19:  ANI/DNIS Digits on Phone Display
(COS Option 502 Enabled and COS Option 613 Disabled)
COS Option 502- Display ANI/DNIS = YES (enable)
COS Option 613 - Display ANI only = NO (disable)
Phone display during 
ringingPhone display after 
answer
ANI and DNIS sentDNISANI
ANI sentANIANI
DNIS sentDNISDNIS
Neither sentTrunk Number or LabelTrunk Number or Label
Table 20:  ANI/DNIS Digits on Phone Display
(COS Option 502 Enabled and COS Option 613 Enabled)
COS Option 502- Display...

Page 135

Programming
125
Programming
The following table describes the set display for logged in ACD Agents 
with the delivery of ANI/DNIS digits on the incoming trunks. 
Table 21:  ANI/DNIS for ACD Agents
COS 
502COS 
613COS 
654 Path 
Name Ringing 
StateTalking
State
Enabled Enabled Disabled None ANI ANI
Enabled Disabled Disabled None DNIS ANI
Disabled Disabled Disabled None Path Number Trunk Name
Disabled Enabled Disabled None Path Number Trunk Name
Disabled Disabled Enabled None Path Number Path Number...

Page 136

Technician’s Handbook
126
Programming a CLASS Trunk
1. Form 01, System Configuration
Program the LS/CLASS Trunk module or the LS/CLASS Trunk card.
2. Form 03, Class of Service, Define for trunks.
To have Calling Line ID digits reported in the SMDR records, enable 
COS Option 806 (SMDR-Record Incoming Calls) and COS Option 
814 (SMDR-Record ANI/DNIS/CLASS). Enable COS Option 702 
(SMDR - Overwrite Buffer).
To have CLASS name reported in the SMDR records, enable COS 
Option 246 (SMDR-Extended Record)...

Page 137

Programming
127
Programming
Program the option “CLASS Trunk” in the circuit descriptor 
options subform for the appropriate 4 or 8-circuit CLASS trunk.
5. Form 14, Non-Dial-In Trunks or Form 15, Dial-in Trunks 
Program the CLASS trunks.
6. Form 04, System Options and Timers
Program the CLASS receivers for the LS/CLASS Trunk module. 
The LS/CLASS Trunk card provides its own CLASS receivers 
and does not require programming in Form 04. 
Programming an SX-200 IP Node
Initializing the SX-200 IP Node
1....

Page 138

Technician’s Handbook
128
9. Press Enter until the [VxWorks Boot] prompt appears.
10. Type ‘@’.
11. After the Critical Alarm LED goes off, reconnect the Ethernet cable.
CDE Programming for the SX-200 IP Node
1. Form 01 - System Configuration
Assign IP Line Cards to slots.
2. Form 04 - System Options
Assign the BCC III Card to the IP Signalling Bay
—Option 116, IP Signalling Bay (1-7) number
—Option 117, IP Signalling Bay IP Address
—Option 118, IP Signalling Bay Gateway Address
—Option 119, IP...

Page 139

Programming
129
Programming
Enter the IP Address Lease Time. Enter the number of minutes 
before a device is disconnected and its IP address is 
re-assigned elsewhere. Applies only to the specific bay. To 
assign an infinite lease time, use 0 minutes. 
Press Enable to enable the DHCP Server.
4. Form 09 - Desktop Device Assignments
Assign the IP phones to Bay/Slt/Ccts.
(Optional) Enter the MAC Addresses of the IP phones.
5. (Optional) Form 02 - Feature Access Codes 
Specify the access codes for the...

Page 140

Technician’s Handbook
130
Programming a Circuit Descriptor for 
Hotel/Motel and ACD Datasets
1. Form 03 - COS Define
Select the COS number. 
Enable the following COS Options:
—901 - DTRX Herald
—904 - DTRX Complete Message Text
—906 - Data SMDR - Does Not Apply
2. Form 29 - DTE Profile
Select a DTE profile number. You will use this profile number in 
Form 12 - Data Assignment.
Select the SEL. Option Subform.
Enable: DTRX Echoplex, Editing, and Edit Character = 127.
3. Form 11 - Data Circuit...