Page 131
Programming 121 Programming 3. Enter valid Bay, Slot and Circuit numbers for the first trunk and press the ENTER softkey. The system displays: TO BAY: SLOT: CIRCUIT:. 4. Enter valid Bay, Slot and Circuit numbers for the last trunk and press the ENTER softkey. 5. The system copies the values from the first trunk to all the trunks specified in the range. Programming a DISA Trunk 1. Form 01, System Configuration Program a trunk card that meets the trunk type requirements. 2. Form 13, Trunk Circuit...
Page 132
Technician’s Handbook 122 Form 33: Enter appropriate DISA access codes. Programming ANI/DNIS on an Incoming Trunk ANI (Automatic Number Identification) - the local carrier sends to the PBX the phone number of the calling party. DNIS (Dialed Number Identification Service) - the local carrier sends to the PBX the digits dialed by the calling party. ANI/DNIS is available only to incoming trunks with trunk descriptor “T1-E&M” and “T1-DID/TIE”, which accept DTMF signaling and have the wink timer active....
Page 133
Programming 123 Programming Wink Timer to 100-350 for MCI and 140-290 for US SPRINT Debounce Timer to 100 ms or greater. 3. To define which information will be displayed on the sets, ANI, DNIS, both, or none (standard trunk label display), select the required following COS options: COS Option 502 - Display ANI/DNIS Information = ENABLE / DISABLE COS Option 613 - Display ANI Information Only = ENABLE / DISABLE COS Option 503 - Display CLASS Name if required. 4. To display ANI and DNIS digits on...
Page 134
Technician’s Handbook 124 Table 19: ANI/DNIS Digits on Phone Display (COS Option 502 Enabled and COS Option 613 Disabled) COS Option 502- Display ANI/DNIS = YES (enable) COS Option 613 - Display ANI only = NO (disable) Phone display during ringingPhone display after answer ANI and DNIS sentDNISANI ANI sentANIANI DNIS sentDNISDNIS Neither sentTrunk Number or LabelTrunk Number or Label Table 20: ANI/DNIS Digits on Phone Display (COS Option 502 Enabled and COS Option 613 Enabled) COS Option 502- Display...
Page 135
Programming 125 Programming The following table describes the set display for logged in ACD Agents with the delivery of ANI/DNIS digits on the incoming trunks. Table 21: ANI/DNIS for ACD Agents COS 502COS 613COS 654 Path Name Ringing StateTalking State Enabled Enabled Disabled None ANI ANI Enabled Disabled Disabled None DNIS ANI Disabled Disabled Disabled None Path Number Trunk Name Disabled Enabled Disabled None Path Number Trunk Name Disabled Disabled Enabled None Path Number Path Number...
Page 136
Technician’s Handbook 126 Programming a CLASS Trunk 1. Form 01, System Configuration Program the LS/CLASS Trunk module or the LS/CLASS Trunk card. 2. Form 03, Class of Service, Define for trunks. To have Calling Line ID digits reported in the SMDR records, enable COS Option 806 (SMDR-Record Incoming Calls) and COS Option 814 (SMDR-Record ANI/DNIS/CLASS). Enable COS Option 702 (SMDR - Overwrite Buffer). To have CLASS name reported in the SMDR records, enable COS Option 246 (SMDR-Extended Record)...
Page 137
Programming 127 Programming Program the option “CLASS Trunk” in the circuit descriptor options subform for the appropriate 4 or 8-circuit CLASS trunk. 5. Form 14, Non-Dial-In Trunks or Form 15, Dial-in Trunks Program the CLASS trunks. 6. Form 04, System Options and Timers Program the CLASS receivers for the LS/CLASS Trunk module. The LS/CLASS Trunk card provides its own CLASS receivers and does not require programming in Form 04. Programming an SX-200 IP Node Initializing the SX-200 IP Node 1....
Page 138
Technician’s Handbook 128 9. Press Enter until the [VxWorks Boot] prompt appears. 10. Type ‘@’. 11. After the Critical Alarm LED goes off, reconnect the Ethernet cable. CDE Programming for the SX-200 IP Node 1. Form 01 - System Configuration Assign IP Line Cards to slots. 2. Form 04 - System Options Assign the BCC III Card to the IP Signalling Bay —Option 116, IP Signalling Bay (1-7) number —Option 117, IP Signalling Bay IP Address —Option 118, IP Signalling Bay Gateway Address —Option 119, IP...
Page 139
Programming 129 Programming Enter the IP Address Lease Time. Enter the number of minutes before a device is disconnected and its IP address is re-assigned elsewhere. Applies only to the specific bay. To assign an infinite lease time, use 0 minutes. Press Enable to enable the DHCP Server. 4. Form 09 - Desktop Device Assignments Assign the IP phones to Bay/Slt/Ccts. (Optional) Enter the MAC Addresses of the IP phones. 5. (Optional) Form 02 - Feature Access Codes Specify the access codes for the...
Page 140
Technician’s Handbook 130 Programming a Circuit Descriptor for Hotel/Motel and ACD Datasets 1. Form 03 - COS Define Select the COS number. Enable the following COS Options: —901 - DTRX Herald —904 - DTRX Complete Message Text —906 - Data SMDR - Does Not Apply 2. Form 29 - DTE Profile Select a DTE profile number. You will use this profile number in Form 12 - Data Assignment. Select the SEL. Option Subform. Enable: DTRX Echoplex, Editing, and Edit Character = 127. 3. Form 11 - Data Circuit...