Page 11
General Description DAV 5 \, BAY 4-5 PCM - CABLE BAY 4, - BAY 2-4 PCM - CABLE -ii-?i-+# RESERVE POWER -- SUPPLV (OPflOPiAL, II! - BAV 4 y- CABLE A clAt/l’IIp BAV 5 POWER SUPPLV Figure 2-5 SX-200@ DIGITAL PABX Peripheral Cabinet Page 2-6
Page 12
General Description 2.06 Power Fail Transfer cards are also provided to enable prese- lected extensions using DTMF or Rotary sets to access a CO trunk in the event of system power failure. 2.07 Two Maintenance Panels are provided. The Control Cabinet Maintenance Panel consists of connections for a test line, a jack for a maintenance Attendant Console, a maintenance terminal and power fail transfer switches. The test line is connected via Tip, Ring and Ground connections or via a standard modular...
Page 13
General Description 3. SYSTEM REQUIREMENTS 3.01 The environmental and electrical requirements for the SX-ZOO(R PABX are shown in Tables 3-l and 3-2 respectively. TABLE 3-l SX-200”’ ENVIRONMENTAL REQUIREMENTS Height Per Cabinet 96.0 cm 38.0 inches Width Per Cabinet 60.0 cm 23.5 inches Depth Per Cabinet 70.0 cm 27.5 inches Weight Fully Loaded 231.0 kg 580.0 pounds Operating Temperature 10 to 40” c 50 to 104’ F Storage Temperature -20 to 50” c -4 to 122” F Relative Humidity (Operating) 20 to...
Page 14
General Description 4. HARDWARE OVERVIEW General 4.01 A block diagram of the SX-2OOe DIGITAL configuration (five bays) is shown in Figure 4-1. Figure 4-2 shows a block diagram of the SX-200@ DIGITAL 336-port configuration (four digital bays). The heart of the system is the Main Controller, a l6-bit microprocessor operating at a clock frequency of 8 megatlertz. The Main Controller, through its address, data, and control buses, interfaces to a floppy disk unit, memory, Direct Memory Access...
Page 15
General Description BAY 1 AND BAY 2 I TO/FROM PERIPHERAL DEVICES BAY 3 3 DATA LINKS I PERIPHERAL CONTROL IRQ PROCESSSOR (6609) PJ D D R E : D A T A DIGITAL A N MEMORY INE&F&E MESSAGE 1 SUBSVSTEM , C 0 :.: 32 SPEECH N : :. PATHS T R 15 0 VOICE L CARDS %FiiER I ITOIFROM I CONTROL PERIPHERAL DEVICES 1; ’ 1 DATALlNK , 1 PERIPHERAL PROCESSOR Figure 4-l 8X-200@ DIGITAL PABX 480-Port Configuration Block Diagram Page 4-2
Page 16
General Description BAY 1 AND BAY 2- _ KAOlBORlE Figure 4-2 SX-200@ DIGITAL PABX 336-Port Configuration Block Diagram Page 4-3
Page 17
General Description Digital Signal Processor (DSP) 4.06 The system contains one Digital Signal Processor (DSP). The DSP is under the control of the .Main Controller and is con- figured to provide the following: m 1 Dial Tone Detector Channel (used for up to 50 trunks) l 18 Channels of Conference (e.g., six 3-party conferences) e 8 Channels of Dual Tone Generators. DX Module 4.07 The DX Module includes a dynamic switch capable of assigning any one of 512 incoming channels to any one of 512...
Page 18
General Description Bay Control Card 4.11 The Bay Control Card interfaces the periphe:al cards of Digital Bays 3 and 4 to the MCC (one BCC for each Bay). Peripheral Control Card 4.12 The Peripheral Control Card controls ail basic functions of the analog Peripheral Cards. The Peripheral Bay controller system also handles real time tasks, such as rotary digit collection, tone cadencing, signaling on trunks, and monitoring hardware activity via the Peripheral Control Bus. All events are reported to...
Page 19
General Description - Receiver/Relay Module: 2 - Music On Hold/Pager Module: 1 - Console Module: 5 - E&M Trunk Module: 3 For example, a Universal Card could be configured with two Console Modules (a total power rating of lo), or one Console Module, two Receiver/Relay Modules, and one Music On Hold/Pager Module (5 + 2 + 2 + 1 = ‘lo). 0 ONS Line Card. There are 12 DTMF/Rotary line circuits per card. The card accepts up to three DTMF/Rotary telephone sets per line circuit. The ONS line card...
Page 20
,General Description 0 SUPERSET” Line Card. This card accepts up to eight SUPERSET 31M or SUPERSET qTM electronic telephone sets (maximum of eight cards per cabinet). A total of 128 SUPERSET@ sets can be supported by the system. l E & M Trunk Card. This card provides two 2- or 4-wire E & M tie trunks. l DID/Loop Tie Trunk Card. This card provides two Direct inward Dial trunks or loop tie trunks. Page 4-7/7