Page 171
SECTION MITL8350-047-l OO-NA TABLE 11 CON’T: SEARCH TABLE ENTRIES FIRST DIGIT = 8 SEARCH TABLES DIAL DEFINITIONS/DESCRIPTIONS #6 This is the last digit of the phone number; any other dialed digits are the account code unless 154t = 1. A route must have been chosen prior to encountering a search table with #6 as an action. #7 Do nothing (wait for more digits). #8 Prefer default route (see x24t). #9 When entered as an action, that template entry is removed from the search table (i.e.,...
Page 172
SECTION MITL8350-047-l OO-NA 5.33 The following paragraphs list the default settings and their descriptions that are included in the search tables when default data is first loaded. SEARCH TABLE 801 AND 821 DEFAULT: 111#71 If the first digit is a 1, do nothing. DEFAULT: 1 x I#71 If the first digit is a x-, do nothing. DEFAULT: I#9 1 0 1 If the first digit is not a 1 or a SC, force the call onto Route #O. SEARCH TABLE 803 AND 823 DEFAULT: )g)/ Stop searching after the receipt of 911. 801...
Page 173
SECTION MITL8350-047-l OO-NA SEARCH TABLE 807 AND 827 DEFAULT: 1 #4 #I #9 5 5 5 0 Place l+N(O or 1)X-555-xXxX calls on Route #O. DEFAULT: #4 #4 #9 #9 #9 #9 #9 #6 T- Stop searching after receipt of NNX-XXXX (local call). SEARCH TABLE 808 AND 828 DEFAULT: #1 #4 #4 #9 #9 #9 #9 #9 #6 Y Stop searching after receipt of l+NNX-XXXX (long distance call within the same area code). SEARCH TABLE 810 AND 830 DEFAULT: #4 #I #9 #9 #9 #9 #9 #9 #9 #9 #6 Stop searching after receipt of N(0 or 1)X-XXX-XxXx...
Page 174
SECTION MlTL8350-047-I OO-NA TABLE 12: SPECIAL FUNCTIONS FIRST DIGIT = 9 DIAL DEFINITION/DESCRIPTION 902 903 904 906 907 908 980mmddhhmm 999 (or go on-hook) Data confirmation mode: After each three digit prefix de- scribed above, the Dialer will display the data if program- ming method 1 is employed, or if using methods 2 or 3, the Dialer will wait for 0.5 seconds, then send the data out in DTMF format. Load default data - delete all non-default data. Clear all searches (including...
Page 175
SECTION MITL8350-047-l OO-NA Note: In the event of an illegal entry, the Dialer will send four long, slow beeps to indicate that the entry has been ignored. Wait for the tones to stop and then try again. METHOD 3 Tandem Mode 5.39 Remote programming may be accomplished using a PC or dumb terminal in conjunction with a Dialer. The local Dialer will perform as an ASCII to DTMF convertor in this mode and also has the advantage of visual feedback while programming a remote Dialer. This mode is also...
Page 176
SECTION MITL8350-047-IOO-NA METHOD 4 Cloning 5.46 “Cloning” is a programming method whereby several Dialers can be programmed to operate identically once one Dialer has been set to the desired functions by another programming method. The Dialer that has the pr8-programmed instructions and is used to ‘clone’ another is called the ‘Master’. The unit to b8 programmed by this method is called the ‘Slave’. 5.47 This method must be accomplished by meeting the following conditions: 1. The Master...
Page 177
SECTION MITL8350-047-l OO-NA Procedure 5.49 1. 2. 3. 4. 5. 6. 7. 8. 9. IO. 11. 12. 5.50 The following steps are the procedure to be accomplished to clone a Dialer: Ensure that the Dialers have been x initialized (see Page IO, para. 3.05). Power up the Master unit. Verify that the desired programming is already resident in the Master unit. Power up the Slave unit. Match the Master and Slave Baud rates. Connect the Master and Slave RS-232 port connectors together with the Cloning...
Page 178
SECTION MlTL8350-047-IOO-NA Do not allow the Master to time out of the program mode or otherwise exit the program mode while the units are connected via the RS-232 Cloning Cable. The resulting SMDR output could cause data corruption of both units. The user may wish to turn the Master SMDR off (009 = 0) during the cloning and later restore it to its original set- ting if needed to minimize this error. A good rule to follow is to only have the Cloning Cable connected while actually cloning the...
Page 180
SECTION MITb6%60-Q47-l OO-NA 6. SPECIFICATIONS HARDWARE 6.01 Table 13 lists all of the hardware specifications for the SMarT- lTM Common Carrier Access Dialer and Call Controller. These specifications also apply to the SMarT-lATM unit unless otherwise noted. TABLE 13: SMarT-lTM HARDWARE SPECIFICATIONS SPECIFICATION MIN. TYP. MAX. UNITS FCC RINGER EQUIVALENCE 0.78 IDLE LINE, LOOP START RINGER IMPEDANCE: 15-60 Hz, 70-IIOV 10 20 K& 20-3500 Hz, 1OV 1 Mfi RINGING SENSITIVITY: 15-60 Hz 40 Volts...