Page 271
FPSA adds security in five ways. First, it can only be activated or deactivated by a special diskette, which will be shipped upon request. The person who loads the diskette (system superuser) is the one person who has access to the entire system. This person assigns passcodes, user IDS, and access privileges. There is no way to bypass the super-user passcode or to activate/deactivate FPSA without this diskette. Second, access to any part of the system (administration menus or QNX) is controlled by...
Page 272
Statistics reports offer the administrator information on usage of line ports, speech storage, trunks, MESA-Net, and messages. Billing reports give information on the breakdown of charges for individual mailboxes by statistic, then calculate the total amount that is due. The four reports cover current and past billing statistics and statistics on terminated mailboxes. The system information reports provide details on system configuration, classes of service, system errors, phone line exceptions and...
Page 273
A number of security features have been added to the Series 6 system to prevent break-in and manipulation from the administrator’s mailbox. For example, the system only allows five seconds of response time for each prompt before it announces “no change” and returns to the administration menu. 9.4 System Backup and Restore Frequent data backups are a very important precaution against inadvertent loss or destruction of data or system information files. The Series 6 system backups are easy because...
Page 274
Section 10: Security Centigram has consistently led the industry in providing system security features at the system level and the mailbox level. The Series 6 platform offers a high degree of protection for system management, administration and maintenance, mailbox usage, and access to network facilities, applications and information. At the record level, all information and database records, regardless of format, are stored on the Series 6 platform in a proprietary Adaptive Digital Pulse Code...
Page 275
Enhanced security is available for all system administration functions on the Series 6 console through Functionally Partitioned System Administration (FPSA). FPSA allows an administrator to create different access privileges, user IDS and passwords for each administrator on the system. Moreover, FPSA provides an audit trail of all system activity and the respective administrator. For more information on FPSA, see section 9.1. 10.1 Disaster Recovery Centigram offers multiple disaster recovery...
Page 276
Section 11: Networking 11.1 MESA-Net MESA-Net provides the critical messaging tool that links the members of your team to your company and to your strategic partners. It links multiple Centigram Series 6 voice and fax servers into one, high-speed global messaging network. MESA-Net bridges geographic distances and time zone differences by allowing you to send messages to and receive responses back from your field sales organization, your sister divisions, your suppliers and your customers at any...
Page 277
For small, very affordable configurations that have occasional network messaging, MESA-Net supports low-cost, dial-up modems. Depending on your messaging traffic, you can design your network to use analog lines, ISDN, 56 kbps lease lines, or El/T1 lines. Interoperate with Third Party Voice Mail Communicating with suppliers and customers is critical to any business. You can set up your Centigram Series 6 server to use AMIS Analog to send and receive voice messages from nearly all third-party voice...
Page 278
MESA-Net Specifications Series 6 servers support one Ethernet 1OBaseT interface and up to 32 WS-232 asynchronous ports. MESA-Net TCP/IP is intended for use with existing corporate wide area networks (WANs) or for connecting several collocated Series 6 severs together. General MESA-Net Specifications - MESA-Net TCP/‘IP - Both MESA-Net Async and TCP/IP (requires MESA-Net TCP/IP Specifications ork connect Series 6 via I Page 36
Page 279
MESA-Net Async Specifications Approximate max. number network messages per node Interface options Transmission speeds 300 messages per hour (assuming: 30 seconds/message - 16 links of RS-232 per module - Maximum 57.6 kbps per link via RS-232 port - 28.8 kbps, full duplex via V.34 modem connection MESA-Net Async Parallel Links 8 parallel links (max throughput depends on Series 6 model1 11.2 AMIS AMIS Analog is a Series 6 system networking application that allows Series 6 systems to...
Page 280
Section 12: Switch Integrations . . Switch integrations establish a connection between a telephone switch and the Series 6 system. This connection provides call information for direct or forwarded calls and message waiting signals for the user, and is transparent to both callers and users. When the telephone switch and the Series 6 system are integrated, the two systems interact to give capabilities that neither system could provide alone. For example, an outside caller is automatically forwarded to...