Page 41

Changing a programme
Provided the Start button has not yet
been pressed,a wrongly selected
programme may be changed as de
-
scribed below (if it has been pressed,
see Cancelling a programme):
^Turn the programme selector to the
required programme.
^Select additional function DRYING
0again if required (see Selecting
an additional function).
^Press the Start button6.
Selecting an additional function
The following additional function can be
selected:
^0DRYING
may be selected as an additional
function as...

Page 42

To cancel a programme
Once a programme is running it should
only be cancelled in extreme cases,
e.g. when articles in the machine rattle
or jostle against each other and have to
be rearranged. See notes in next sec
-
tion regarding the control of epidemics.
^Turn the programme selector to the
fposition (the programme is can
-
celled after approx. 2 secs.).
^Open the doora
Caution. Water and items in the ma
-
chine may be hot. Danger of burning
or scalding.
^Arrange the load securely,
(wear protective...

Page 43

For future servicing work, please
document any alterations to the stan
-
dard factory settings.
Enter any alterations in the field
Value set:_________.
General notes:
–Switch positions that have not been
allocated a function are indicated in
the middle part of the display by a
bar (-).
–The programming level is called up
via the STOP positionf.
– If any changes have been made to
programmes or dispensing systems
these must be documented in a log
book kept with the machine in accor-
dance with the Medical...

Page 44

1.1.2 Venting the dispensing system:
a) After setting the dosage concentra
-
tion:
^Turn the programme selector to theA
position. do1 appears in the display.
^Pressß.
The dispensing system will be vented
automatically. 0 will appear in the dis
-
play when venting is finished.
Having changed a value or all values:
^Press the6button. SP appears.
^Press6again. The change has
been recorded.
b) If only venting
is required (e.g. be-
cause the dispensing system has been
allowed to empty by mistake)
^Select...

Page 45

1.2 DOS 3 (Neutralising agent)
1.2.1 Setting the dosage concentra
-
tion:
Set the dosage concentration accord
-
ing to the neutralising agent manufac
-
turer’s recommendations.
Example: If the manufacturer recom
-
mends a concentration level of 0.3 %
set the value to 0.30.
^Turn the programme selector to the
CHEM 60°C-5’position. The dosage
concentration set will appear as a %
in the display:
0.05 - 0.50 = 0.05 % - 0.5 % dosage
concentration.
^Pressßas many times as neces-
sary or hold it pressed in...

Page 46

1.3 DOS 4 (chemical disinfecting
agent) via the optional DOS-Module
G 60 or C 60 .
1.3.1 Setting the dosage concentra
-
tion:
^Set the dosage selector on the
DOS-Module to position 10 (applies
to DOS Module C 60 only).
Set the concentration level according to
the disinfecting agent manufacturer’s
recommendations.
Example: If the manufacturer recom
-
mends a concentration level of 1 % set
the value to 1.00.
^Turn the programme selector to the
varioTD ANposition. The dosage
concentration set will appear as...

Page 47

2. Altering the wash tempera
-
ture and/or the temperature
holding time in the "Main
wash"
(except with the SPECIAL
(AN) 93°C10’
programme) and
"Final rinse" programme
stages
Please make a note of any changes
to the temperature and / or the tem
-
perature holding time in the appropri
-
ate section of the programme chart
.
The programme chart shows the factory
settings for the Main wash temperature
together with temperature holding time
and the Final rinse temperature
with its
temperature...

Page 48

^Pressßor hold pressed in, until the
required value appears in the display.
Final rinse temperature:
^Turn the programme selector to the
STOP positionf.
^Press0as often as necessary or
hold it pressed in until E25 (pro
-
gramming level 25 = Final rinse 2)
appears in the display. Then:
^Turn the programme selector back to
the programme which needs to be
changed. The actual value appears
in the display field after°C.
^Pressßor hold pressed in, until the
required value appears in the display.
Note:
When...

Page 49

3. Audible tone (Buzzer)
This special function allows you to
programme a buzzer (lasting up to a
maximum of 30 seconds) for the follow
-
ing functions:
–Programme end = Constant buzzer
–Fault warning = Buzzer at one sec
-
ond intervals
–Removing a test item from the final
rinse water (this function has to be
programmed by a Miele service en
-
gineer)
= 3 x short beeps followed by 2 sec
-
ond pause, then 3 short beeps etc.
^Turn the programme selector to the
STOP positionf.
^Switch off the machine.
^Press...

Page 50

4. Re-setting all parameter
changes back to the factory
settings.
^Turn the programme selector to the
STOP positionf.
^Switch off the machine.
^Press and holdßand6at the
same time, and whilst doing so,
switch the machine on with theI-0
button.
The current programme status P...
will appear in the display and thep/
6indicator light will come on.
^Press0as often as necessary or
hold it pressed in until E33 (pro-
gramming level 33) appears in the
display.
^Turn the programme selector to any
switch position...
Start reading Miele G 7882 Manual