Page 51

Cleaning the filters in the wash
cabinet
,This machine must not be used
without all the filters in place.
The filter combination in the base of
the wash cabinet should be in
-
spected regularly and cleaned if nec
-
essary.
,Caution
Watch out for glass splinters which
could cause injury.
Cleaning the coarse filter
^
Press the two lugs together, remove
and clean the coarse filter.
^
Put the clean filter back in position
and press until it clicks in place.
Cleaning the fine, flat and micro-fine
filters
^...

Page 52

Cleaning the spray arms
Waste particles can lodge in the spray
arm jets.
It is therefore important to inspect the
spray arms regularly.
^Use a sharp pointed object to push
particles into the spray arm jets and
rinse well under running water.
Remove the spray arms as follows:
^Unscrew theupperspray arm.
^Remove themiddlespray arm by un
-
screwing the nut
which secures it to
the upper basket.
Important:
The nut has a left hand
thread and has to be turned clock-
wise to unscrew it.
^Loosen the knurled thumb...

Page 53

Cleaning the drain pump and
non-return valve
If water has not been pumped away at
the end of a programme the drain
pump or the non-return valve might be
blocked. They are however, easy to
clean.
^Take the filter combination out of the
wash cabinet.
^
Release the locking clamp.
^
Lift up the non-return valve and rinse
under running water.The drain pump is situated under the
non-return valve (see arrow).
^Before replacing the non-return valve
check that the drain pump is free of
obstructions.
^Carefully...

Page 54

Cleaning the filters in the water
inlet
Filters are incorporated in the screw
connection of the water inlet hose to
protect the water inlet valve. If these fil
-
ters get dirty they need to be cleaned,
otherwise insufficient water flows into
the wash cabinet.
,The plastic housing of the water
connection contains an electrical
component. It must not be dipped in
water.
To clean the filters
^Disconnect the machine from the
mains supply (switch off at the mains
and pull out the plug, switch off the...

Page 55

With the aid of the following explanatory
notes, minor faults can be corrected
without contacting the Miele Service
Dept.
Any work on the electrical components
of the machine should only be carried
out by a suitably qualified and compe
-
tent person in accordance with local
and national safety regulations. Un
-
authorised repairs could be dangerous.
Faults / possible causes
The machine does not start
– The door is not properly closed.
– The plug is not properly inserted in
the socket.
– The fuse is...

Page 56

After sales service
Important:
When a fault first occurs, please check
that the fault has not been caused by
incorrect operation. This will help avoid
an unnecessary service call-out. To do
this:
^Turn the programme selector to the
STOP positionf(the fault code goes
out).
^Switch the machine off (pressI-0).
^Switch the machine on again and
reselect the programme.
If you still have difficulties or if a fault
code F... appears in the display,
please contact your authorised Service
Dealer or the Miele...

Page 57

Please refer to the installation dia
-
gram supplied with the machine.
,Furniture and fittings installed
near the machine must be of a com
-
mercial standard able to withstand
the effects of steam and condensed
water.
The machine must be installed correctly
and levelled.
Any unevenness in the floor level can
be compensated for and the height of
the machine raised or lowered by ad
-
justing the four screw feet.
The machine can be installed in the fol-
lowing ways:
^Free-standing.
^Slot-in or at the end of...

Page 58

Position and secure the machine
To ensure stability the machine must
first be aligned and then screwed to the
worktop.
^Open the door. Secure the machine
to the front edge of the worktop using
screws through the holes on the left
and right hand sides of the front trim.
^Do not use silicone sealant to seal
the gaps between the machine and
any neighbouring units as this would
hinder ventilation to the circulation
pump.
Depending on the requirements for
building under, the following kit
can be
ordered from...

Page 59

,All electrical work must be car
-
ried out by a suitably qualified and
competent person in accordance
with local and national safety regula
-
tions.
^Connection should be made via a
suitable isolator, with an on-off switch
which should be easily accessible for
servicing work.
^For extra safety it is advisable to in
-
stall a residual current device with a
trip current of 30 mA (in accordance
with DIN VDE 0664).
WARNING
THIS APPLIANCE MUST BE
EARTHED
^Equipotential bonding should be car-
ried out....

Page 60

To re-assemble:
^Refit the plastic protective cap, plinth
facing and service panel in the re
-
verse order to which they were re
-
moved.
See also the installation diagram sup
-
plied.
Electrical connection
56 