Page 51
Cleaning the filters in the wash cabinet ,This machine must not be used without all the filters in place. The filter combination in the base of the wash cabinet should be in - spected regularly and cleaned if nec - essary. ,Caution Watch out for glass splinters which could cause injury. Cleaning the coarse filter ^ Press the two lugs together, remove and clean the coarse filter. ^ Put the clean filter back in position and press until it clicks in place. Cleaning the fine, flat and micro-fine filters ^...
Page 52
Cleaning the spray arms Waste particles can lodge in the spray arm jets. It is therefore important to inspect the spray arms regularly. ^Use a sharp pointed object to push particles into the spray arm jets and rinse well under running water. Remove the spray arms as follows: ^Unscrew theupperspray arm. ^Remove themiddlespray arm by un - screwing the nut which secures it to the upper basket. Important: The nut has a left hand thread and has to be turned clock- wise to unscrew it. ^Loosen the knurled thumb...
Page 53
Cleaning the drain pump and non-return valve If water has not been pumped away at the end of a programme the drain pump or the non-return valve might be blocked. They are however, easy to clean. ^Take the filter combination out of the wash cabinet. ^ Release the locking clamp. ^ Lift up the non-return valve and rinse under running water.The drain pump is situated under the non-return valve (see arrow). ^Before replacing the non-return valve check that the drain pump is free of obstructions. ^Carefully...
Page 54
Cleaning the filters in the water inlet Filters are incorporated in the screw connection of the water inlet hose to protect the water inlet valve. If these fil - ters get dirty they need to be cleaned, otherwise insufficient water flows into the wash cabinet. ,The plastic housing of the water connection contains an electrical component. It must not be dipped in water. To clean the filters ^Disconnect the machine from the mains supply (switch off at the mains and pull out the plug, switch off the...
Page 55
With the aid of the following explanatory notes, minor faults can be corrected without contacting the Miele Service Dept. Any work on the electrical components of the machine should only be carried out by a suitably qualified and compe - tent person in accordance with local and national safety regulations. Un - authorised repairs could be dangerous. Faults / possible causes The machine does not start – The door is not properly closed. – The plug is not properly inserted in the socket. – The fuse is...
Page 56
After sales service Important: When a fault first occurs, please check that the fault has not been caused by incorrect operation. This will help avoid an unnecessary service call-out. To do this: ^Turn the programme selector to the STOP positionf(the fault code goes out). ^Switch the machine off (pressI-0). ^Switch the machine on again and reselect the programme. If you still have difficulties or if a fault code F... appears in the display, please contact your authorised Service Dealer or the Miele...
Page 57
Please refer to the installation dia - gram supplied with the machine. ,Furniture and fittings installed near the machine must be of a com - mercial standard able to withstand the effects of steam and condensed water. The machine must be installed correctly and levelled. Any unevenness in the floor level can be compensated for and the height of the machine raised or lowered by ad - justing the four screw feet. The machine can be installed in the fol- lowing ways: ^Free-standing. ^Slot-in or at the end of...
Page 58
Position and secure the machine To ensure stability the machine must first be aligned and then screwed to the worktop. ^Open the door. Secure the machine to the front edge of the worktop using screws through the holes on the left and right hand sides of the front trim. ^Do not use silicone sealant to seal the gaps between the machine and any neighbouring units as this would hinder ventilation to the circulation pump. Depending on the requirements for building under, the following kit can be ordered from...
Page 59
,All electrical work must be car - ried out by a suitably qualified and competent person in accordance with local and national safety regula - tions. ^Connection should be made via a suitable isolator, with an on-off switch which should be easily accessible for servicing work. ^For extra safety it is advisable to in - stall a residual current device with a trip current of 30 mA (in accordance with DIN VDE 0664). WARNING THIS APPLIANCE MUST BE EARTHED ^Equipotential bonding should be car- ried out....
Page 60
To re-assemble: ^Refit the plastic protective cap, plinth facing and service panel in the re - verse order to which they were re - moved. See also the installation diagram sup - plied. Electrical connection 56