Page 131
2.8.21 E 21, Program-Dependent Activation of 10th Wash Block NS1 (Final Rinse 1) For programming mode access, see Programming Mode Summary, 070 4.1. x Program Level E 21 Program Selector Switch SettingDisplay Function (Depending on Cleaning Program) 1 o'clock10Flashing display, wash block 10 NS1 (final rinse 1) not active 10 –Constant display, dash at top: wash block 10 NS1 (final rinse 1) activated with KW (cold water) 10–Constant display, dash in middle: wash block 10 NS1 (final rinse 1) activated...
Page 132
Program Level E 23 Program Selector Switch SettingDisplay Function (Depending on Cleaning Program) 1 o'clock e.g., 10Setting the holding time t5 in temperature step T5 in 1-min steps, between 1 min and 15 min 2 o'clockAs described for the 1 o'clock setting, but only applicable for the cleaning program that can be started at the 2 o'clock setting 3 o'clockAs described for the 1 o'clock setting, but only applicable for the cleaning program that can be started at the 3 o'clock...
Page 133
Program Level E 25 Program Selector Switch SettingDisplay Function (Depending on Cleaning Program) 3 o'clockAs described for the 1 o'clock setting, but only applicable for the cleaning program that can be started at the 3 o'clock setting etc. . . . . . . Table 34:Program LevelE 25 2.8.26 E 26, Program-Dependent Setting of Temperature Holding Time t2 in Wash Block NS2 (Final Rinse 2) For programming mode access, see Programming Mode Summary, 070 4.1. x Program Level E 26 Program Selector...
Page 134
For programming mode access, see Programming Mode Summary, 070 4.1. x Program Level E 28 Program Selector Switch SettingDisplay Function (Depending on Cleaning Program) 1 o'clock e.g., 55Temperature setting in 1°C steps between 30°C and 99°C 2 o'clockAs described for the 1 o'clock setting, but only applicable for the cleaning program that can be started at the 2 o'clock setting 3 o'clockAs described for the 1 o'clock setting, but only applicable for the cleaning program that can...
Page 135
Program Level E 30 Program Selector Switch SettingDisplay Function (Depending on Cleaning Program) 3 o'clockAs described for the 1 o'clock setting, but only applicable for the cleaning program that can be started at the 3 o'clock setting etc. . . . . . . Table 39:Program LevelE 30 2.8.31 E 31, Program-Dependent Temperature Setting for Drying TA2 G 7882 CD, G 7883 CD For programming mode access, see Programming Mode Summary, 070 4.1. x Program Level E 31 Program Selector Switch SettingDisplay...
Page 136
2.8.33 E 33, Resetting Electronic For programming mode access, see Programming Mode Summary, 070 4.1. x Program Level E 33 Program Selector Switch SettingDisplay Function (Depending on Cleaning Program) Immaterial00Unprogrammed electronic - Cannot be modified PPWith programmed electronic - Can be reset to00or back to PP Table 42:Program LevelE 33 2.8.34 E 34, Clock Setting (From P 06) For programming mode access, see Programming Mode Summary, 070 4.1. x Program Level E 34 Program Selector Switch...
Page 137
Service Level S 21 Program Selector Switch SettingDisplay Function 4 o'clock 4) 40Serial printer interface not available 41Serial printer interface activated 42Serial printer interface activated and test printout. In order to receive a printout immediately after entry, press theStart button twice (save). 5 o'clockCoarse filter operating hours 2)in h (e.g., 250)— 6 o'clockFine filter operating hours 2)in h (e.g., 500)— 7 o'clockCoarse filter operating hours with reset 3)(e.g., 010)— 8...
Page 138
Service Level S 22 Program Selector Switch SettingDisplay Function 6 o'clock e.g., 11Hour setting (01 - 23) 7 o'clock e.g., 45Minute setting (01 - 59) 8 o'clock e.g., 108Capacity - DOS dispenser pump 1, range 10 - 150 mL/min 9 o'clock—DOS dispenser pump 2 is rinse aid door dispenser, no capacity setting 10 o'clock e.g., 18Capacity - DOS dispenser pump 3, range 10 - 150 mL/min 11 o'clock e.g., 110Capacity - DOS dispenser pump 4, range 10 - 150 mL/min Table 45:Service LevelS 22...
Page 139
2.9.4 S 24, Checking Outputs 12 - 19 For service mode 2 access, see Service Mode 2 Summary, 070 4.3. x Service Level S 24 Program Selector Switch SettingDisplay Function 1 o'clock—Vacant 2 o'clock 12 1)Output 12: DOS 4 dispenser, disinfectant 3 o'clock 13 1)Output 13: DOS 3 dispenser, neutralizing agent 4 o'clock 14 2)Output 14: Drying unit base load 5 o'clock 15 2)Output 15: Drying unit control 6 o'clock 16 2)Output 16: Drying unit fan 7 o'clock 17 2)Output 17: DK3), no...
Page 140
Service Level S 25 Program Selector Switch SettingDisplay Function 11 o'clock00 Machine number deleted PP Machine number programmed Table 48:Service LevelS 25 Note The set machine number is recorded in a printout via the serial interface. 2.9.6 S 26, Special Functions For service mode 2 access, see Service Mode 2 Summary, 070 4.3. From P 05: Program interruption possible. From P 05: Display for machines without steam condenser (DHK), display only for machines with pulsed heating. Dispensing relay...