Miele G 7881 Service Manual
Here you can view all the pages of manual Miele G 7881 Service Manual. The Miele manuals for Washer Disinfector are available online for free. You can easily download all the documents as PDF.
Page 81
2.6 Level Switches 2.6.1 Float Switch B8/3 If a water intake hose should leak, the leaking water flows along the outer hose sleeve to the drip pan in the bottom of the machine. When a certain quantity of water has collected in the drip pan, float switch B8/3 (050 Fig. 1, Pos. 8) acts to stop the water flow by closing the WPS solenoid valves Y1, Y12 and/or Y20, resulting in fault codeF 26(070 Table 51). At the same time, the drain pump is activated to remove the wash water from the cabinet.The drain pump...
Page 82
2.7 NTC Temperature Sensors x NTC Sensor Resistance Values Temperature (°F) Temperature (°C) Resistance (kΩ) 32 0 Approx. 35.9 41 5 Approx. 28.5 50 10 Approx. 22.7 59 15 Approx. 18.2 68 20 Approx. 14.7 77 25 Approx. 11.9 86 30 Approx. 9.7 95 35 Approx. 8.0 104 40 Approx. 6.6 113 45 Approx. 5.5 122 50 Approx. 4.6 131 55 Approx. 3.8 140 60 Approx. 3.2 149 65 Approx. 2.7 158 70 Approx. 2.3 167 75 Approx. 1.9 176 80 Approx. 1.7 185 85 Approx. 1.4 194 90 Approx. 1.2 199 93 Approx. 1.1 203 95 Approx. 1.0 Table...
Page 83
3 Fault Repair 3.1 Heating Level Switch Does Not Switch On Cause Heating level switch does not react to water pressure. Remedy ACheck the switching point and continuity of the heating level switch. AReplace the heating level switch, if necessary. Cause Excessively foaming detergent or rinse aid in the wash water. This reduces the wash water pressure developed by the circulation pump and applied to the heating level switch. Remedy AUse a different detergent or rinse aid. 3.2 Premature Failure of...
Page 84
x Note To protect seals, do not use disinfecting, alkaline detergents with a high proportion of active chlorine at temperatures above 176°F (80°C). 3.3 Circulation Pump Does Not Start Cause Circulation pump motor winding too hot and the winding protection device 1F3 has tripped (it resets automatically after about 10 minutes). Foreign objects may be blocking the pump. Remedy ACheck the circulation pump for correct operation; see 070 2.9.3S 23, Checking Outputs 1 to 11. ACheck the circulation pump...
Page 85
4 Service 4.1 Speed Sensor B3/9 Check AActivate the circulation pump in service mode 2 (070 2.9.3S 23, Checking Outputs 1 to 11). AIf the circulation pump starts briefly (3 start attempts) and then stops, then the speed sensor is not providing any pulses (display flashes). 4.2 NTC Temperature Sensor Replacement x Fig. 2:Temperature Sensor with Housing AService Panel Removal, 022 4.2. AToekick Removal, 010 4.6. ARemove the holding bracket (080 Fig. 4, Pos. 2) by removing the retaining screws (080 Fig. 4,...
Page 86
4.3 Drain Pump Removal AService Panel Removal, 022 4.2. ARemove the left side panel (Side Panel Removal, 010 4.1), if possible. ARemove the terminal block mounting bracket. ATwist the pump clockwise to unlock; remove the red clip, if applicable (usually found on older models). ADisconnect the electrical connection. APull the pump out of the machine. 4.4 Sump Removal ATilt the machine onto its right side. ARemove the bottom pan. ARemove the heater relay mounting bracket. ADisconnect the drain pump hose...
Page 87
4.6 Circulation Pump/Speed Sensor Removal ATilt the machine onto its right side. ARemove the bottom pan. ADisconnect the sump hose in front of the circulation pump. ADisconnect all visible hoses from the pump (one is connected to the heater pressure switch). ADisconnect the speed sensor wiring harness (red/yellow). ADisconnect the electrical connection from the circulation pump. ARemove the 8mm bolt securing the circulation pump to the machine rear panel. ATake the pump out and unclamp a third hose....
Page 88
061 Air Vent, Cabinet Ventilation G 7882 CD, G 7883 CD x Descriptive Technical Documentation DTD no. 62-7881 061-1 18.09.2013, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved.
Page 89
1 Technical Data Technical data currently not available. Descriptive Technical Documentation 061-2 DTD no. 62-7881 This information should not be duplicated or passed on without Miele approval. All rights reserved. 18.09.2013, US_am
Page 90
062 Steam Condenser G 7881, G 7882, G 7883 x Descriptive Technical Documentation DTD no. 62-7881 062-1 18.09.2013, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved.