Page 71
3 Fault Repair 3.1 No Water Intake Symptom Water intake only starts after rotation of the circulation pump has been registered; see 050 2.4 Circulation Pump M6. Cause Circulation pump is not running. Remedy ACheck the circulation pump for power or mechanical failure. ASpeed Sensor B3/9 Check, 050 4.1. Cause WaterProof System (WPS) valve does not open. Remedy ASee fault codeF 0Ein 070 2.11.2 Intake/Drain Fault LED and/or 070 Table 51. 3.2 Minimum/Maximum Number of Flow Meter Pulses Not Achieved Cause Flow...
Page 72
Remedy ACheck the reed switch for correct operation and seating. ACheck the reed switch connections and plugs. AIf necessary, replace the reed switch; see Reed Switch (Supply Water Flow Meter) Replacement, 041 4.2. Descriptive Technical Documentation DTD no. 62-7881 041-15 18.09.2013, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved.
Page 73
4 Service 4.1 Reed Switch B8/2 (Salt Container Float Switch) Replacement AService Panel Removal, 022 4.2. ADisconnect the plug connection from the reed switch. AUse needlenose pliers to remove the circuit board (PCB) with reed switch from the salt container. ASlide the PCB with the new reed switch into the holder until it clips into position. AReconnect the plug connection. 4.2 Reed Switch (Supply Water Flow Meter) Replacement AService Panel Removal, 022 4.2. x Note The flow meter is behind temperature...
Page 74
4.3 Flow Meter (Cold Supply Water) Replacement AService Panel Removal, 022 4.2. ARemove the screws securing temperature limiter F2 (030 Fig. 3, Pos. 2). ACarefully lift the temperature limiter slightly. ASlide the flow meter up and out of its holder on the water softener. ADisconnect the plug connection from the reed switch and disconnect the hoses. AInstall the new flow meter by following these instructions in reverse order. 4.4 Water Diverter Removal ARemove the right-hand side panel (Side Panel...
Page 75
042 Demineralized-Water Intake x Descriptive Technical Documentation DTD no. 62-7881 042-1 18.09.2013, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved.
Page 76
1 Technical Data Solenoid Data Valve VoltageFlow PressureFlow RateConnection Length 1)Threaded Union Demineraliz- ed water (Y20)1N AC 220/240 V 50/60 Hz21.8 - 145 psi (1.5 - 10 bar) 2) 2.1 gal/min (7.5 L/min)5.6' (1.7 m) 3/4" Table 1:WaterProof System Data (as per Parts CD) 1)The standard WaterProof system hose can be replaced with a 14.8-foot (4.5-meter) version.2)With a pressure of 7.3 to 21.8 pounds per square inch (0.5 to 1.5 bar), the water intake time is automatically extended by up to 5...
Page 77
050 Drainage, Sump, Circulation Pump Descriptive Technical Documentation DTD no. 62-7881 050-1 18.09.2013, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved.
Page 78
1 Technical Data Type VoltagePower RatingMax. Flow PressureMax. Flow RateWinding Protection Drain pumpBE28B31N AC 200/ 220 V 60HzApprox. 80 VA—min. 4.2 gal/min (16 L/min)Integrated Circulation pumpMPE 11– 64/21N AC 220V 60HzApprox. 600 VA13 psi (0.9 bar)106 gal/min (400 L/min)Integrated Table 1:Pump Data (as per Parts CD) Descriptive Technical Documentation 050-2 DTD no. 62-7881 This information should not be duplicated or passed on without Miele approval. All rights reserved. 18.09.2013, US_am
Page 79
2 Function 2.1 Sump and Associated Components x Fig. 1:Sump and Associated Components 1 Float switch holder 2 Drain pump, M8 3 Heater level switch, B1/10 4 Circulation pump, M6 5 Speed sensor, B3/9 6 Water intake level switch, B1/1 7 Float switch housing 8 Float switch, B8/3 9 Float Descriptive Technical Documentation DTD no. 62-7881 050-3 18.09.2013, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved.
Page 80
2.2 Drainage The machine comes supplied with a 5-foot, flexible drain hose (7⁄8-inch inner diameter). In non-CD models, the steam condenser is drained internally through the existing drain hose. The machine has a removable non-return valve. The drain height should not exceed 3 feet. Floor drains are permissible; additionally, the drain hose may be lengthened to 13 feet. 2.3 Drain Pump M8 Drain pump M8 (050 Fig. 1, Pos. 2) is located below the cabinet and is connected to the right of the sump. It is...