Page 161

2.2 Program Sequence Plans - EGPL 081
For program sequence plans for G 7882 CD and G 7883 CD, see 070 2.7
Software Index Versions, Program Sequence Plans.
2.3 Programming Mode - Programming Levels E 01 to E 34
(Programming Mode)
See 070 2.8 Programming Mode - Programming LevelsE 01toE 34.
2.4 Service Mode 2 - Service Levels S 21 to S 27
See 070 2.9 Service Mode 2 - Service LevelsS 21toS 27.
Descriptive Technical Documentation
DTD no. 62-7881 072-5
18.09.2013, US_am This information should not be...

Page 162

080 Electrical Installations
x
Descriptive Technical Documentation
DTD no. 62-7881 080-1
18.09.2013, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved. 

Page 163

2 Function
2.1 Electronic (2N1) Plug Allocation
2.1.1 Electronic EZL (031) 081
x
Fig. 1:Electronic EZL (031) 081 Plug Allocation
1 Plug connection ST 4 - I
2C bus (internal interface)
2 Plug connection ST 3 - One output with supply voltage and two
inputs (digital)
3 Plug connection ST 2 - Four outputs with supply voltage
4 Plug connection ST 1 - Three outputs with supply voltage and one
input (digital)
2.1.2 Terminal Allocation of Individual Plugs on Electronic EZL (031) 081
Individual plugs (see 080...

Page 164

–Contact 8, AD (demineralized water) - GND
–Contact 7, AD (demineralized water) - Signal
–Contact 6, KW (cold water) - Signal
–Contact 5, KW (cold water) - GND
Plug 9
–Contact 4, WW (hot water) - GND
–Contact 3, DK WW (steam condenser hot water) - Signal
–Contact 2, condensate pump (M13)
–Contact 1, N
Plug 10(solenoid valve, steam condenser, cold)
–Contact 7, solenoid valve 1Y22
–Contact 6, GND
Plug 11(solenoid valve, steam condenser, cold)
–Contact 5, solenoid valve 2Y22
–Contact 4, GND
Plug 12(CD...

Page 165

The leads are connected to the DOS module dispenser (DOS 4) connections on
the back of the machine, D Layout of Electrical Components 1.
–Contact 2, M9/7, DOS 4
–Contact 1, N
2.2 Dispensing Monitor EZQ 081
2.2.1 EZQ 081 Function
Auxiliary electronic EZQ 081 (dispenser relay check)interrupts the neutral
conductor of the voltage supplyto all dispensing systems if the maximum
dispensing time of 7 minutes has been exceeded by one dispensing system.
2.2.2 Plug Allocation EZQ 081
x
Fig. 2:EZQ 081 Electronic...

Page 166

–Contact 1–GND
–Contact 2–Data link to I
2C bus
–Contact 3–Data link to I
2C bus
–Contact 4–(+) 8VDC
2.3 Wiring Diagram and Legend
2.3.1 Wiring Diagrams
G 7881
The following wiring diagrams are applicable for the G 7881.
x
Diagram no. Description
05746271 Without dispensing check or EZQ 081
(dispensing relay check) module.
06000381 Without dispensing check or EZQ 081
(dispensing relay check) module. New wiring
for solenoids Y20 and Y1 (demineralized and
cold water intakes).
06869610 With dispensing check...

Page 167

2F3 Drain pump winding protection
F7 Fine-wire fuse
1K1/1 Heater relay (water/pulsed drying)
2K1/1 Heater relay (water only)
M6 Circulation pump
M8 Drain pump
M9/3 Acidic acid dispenser pump
M9/5 Detergent dispenser pump
M13 Condensate drain pump
1N1 Electronic
2N1 Electronic
3N1 Electronic
7N1 Electronic
8N1 Electronic
N2 Speed selector
R1 Heater element 1 (water + drying)
R2 Heater element 2 (water)
R3 Heater element 3 (water)
1R30 NTC temperature sensor (water)
2R30 NTC temperature sensor (water)
3R30...

Page 168

2.4 Power Supply Connection Conversion Possibilities
These machines are supplied as standard for connection to 3 AC 208V 60Hz.
Connection to one or two phases is possible but this results in a heating power
reduction; see C Table 2. If a heater rating of 6kW is to be achieved with
connection to a single phase, then the connection of the heater elements and
power supply should be modified in accordance with the following diagram.
x
Fig. 3:Heating Connection (6kW) with 208VAC
Warning!
Connection of the...

Page 169

3 Fault Repair
3.1 No Voltage for Relay Solenoid 1K1/3 in Drying Unit (TA)
G 7882 CD, G 7883 CD
Cause
No voltage between contacts 3 (TA on) and 1 (N) of plug 12 on ELZ 081
electronic.
Remedy
ADisconnect plug 12 and check output 16 via the service mode, 070 2.9.4S 24,
Checking Outputs 12 - 19.
AIf no voltage is present, check the voltage supply for EZL 081 via main switch
S2 and door contact switch 1S4 at plug 13, contact 3 (L1) and 4 (N).
AIf voltage is present, replace the electronic; see Electronic...

Page 170

3.3 Load Does Not Dry
Cause
Heater relay 1K1/1 does not switch.
Remedy
ASee also Suds Warm Up Too Slowly/Wash Cycles Take Longer to Heat
Water, 080 3.2.
Cause
Heater element R1 defective.
Remedy
ACheck heater element R1 for continuity; see Checking the Heater Element,
030 4.1.
AIf necessary, replace the heater element; see Heater Element Replacement,
030 4.5.
Descriptive Technical Documentation
DTD no. 62-7881 080-9
18.09.2013, US_am This information should not be duplicated or passed on without Miele...
Start reading Miele G 7881 Service Manual

Related Manuals for Miele G 7881 Service Manual