Page 151

What’s New in DEFINITY ECS
Release 8.2 Job Aid  555-233-754  Issue 1
April 2000
Networking Enhancements 
145 Networking - ISDN Private 
2
Figure 9. Basic QSIG-VALU Call Coverage Scenario
QSIG-VALU Call Coverage will enhance the operations for the users, similar to 
DCS Call Coverage, in the following ways:
1.Principal’s coverage path and criteria will be used to re-direct the call to 
QSIG-VALU coverage points. 
2. If the QSIG-VALU coverage point is not available, and the call can be 
redirected to the...

Page 152

What’s New in DEFINITY ECS
Release 8.2 Job Aid  555-233-754  Issue 1
April 2000
Networking Enhancements 
146 Networking - ISDN Private 
2
5. Principal user will be able to bridge on to the call while the call is routed to 
QSIG-VALU coverage points and after the call is answered by the coverage 
point.
6. Calling party will hear a coverage redirection tone before the call is routed 
to the 1st coverage point if the caller is on the same DEFINITY PBX as the 
Principal, or if the incoming call received...

Page 153

What’s New in DEFINITY ECS
Release 8.2 Job Aid  555-233-754  Issue 1
April 2000
Networking Enhancements 
147 Networking - ISDN Private 
2
These enhancements require the administration of existing fields as follows:
nThe system-parameters customer-option form must be administered 
with option V8 or later for field G3 version
nThe system-parameters customer-option form must be administered 
with option y(es) for field ISDN PRI, or it must be administered with 
option y(es) for field ISDN-BRI trunks.
nThe...

Page 154

What’s New in DEFINITY ECS
Release 8.2 Job Aid  555-233-754  Issue 1
April 2000
Networking Enhancements 
148 Networking - ISDN Private 
2
Display Enhancements
Release Link Trunks (RLT) are limited in the amount of information that can be 
passed and displayed to the attendant.  CAS Display Enhancements are possible 
by replacing RLT with QSIG ISDN trunks.  Display enhancements are achieved by 
using QSIG MSI messages.  Display enhancements for calls coming into the 
attendant from a branch are:  
nFor an...

Page 155

What’s New in DEFINITY ECS
Release 8.2 Job Aid  555-233-754  Issue 1
April 2000
Networking Enhancements 
149 Networking - ISDN Private 
2
NOTE:
DEFINITY One and Guestworks are not supported.
Voice mail systems that support these connections are:
nIntuity AUDIX R4.4 or higher running on a MAP5, with up to 18 ports
nOctel 100, with up to 16 ports
Configuration requirements
Centralized voice mail via mode code requires the following:
nA DEFINITY ECS switch as the hub of the voice mail network, with the...

Page 156

What’s New in DEFINITY ECS
Release 8.2 Job Aid  555-233-754  Issue 1
April 2000
Networking Enhancements 
150 Networking - ISDN Private 
2
Figure 10. Centralized Voice Mail Via Mode Code Example Configuration
Feature Support
Features that are supported are:
nCalling party name/number sending/retrieval
nMessage waiting light activation
nRemote coverage to voice mail
nFax, as well as voice, mail
Features Not Supported
The following capabilities are not supported via mode code. 
nMost DCS feature...

Page 157

What’s New in DEFINITY ECS
Release 8.2 Job Aid  555-233-754  Issue 1
April 2000
Networking Enhancements 
151 Networking - ISDN Private 
2
Setting Up Centralized Voice Mail Via Mode 
Code
The following step describe how to set up DEFINITY switches to support 
centralized voice mail. For information on setting up Merlin Legend/Merlin Magix, 
see 
Merlin Magix Integrated Systems Network Reference, 555-715-114. For 
information on setting up 
INTUITY Messaging Solutions, see INTUITY Messaging 
Solutions...

Page 158

What’s New in DEFINITY ECS
Release 8.2 Job Aid  555-233-754  Issue 1
April 2000
Networking Enhancements 
152 Networking - ISDN Private 
2
—Send Name field is y.
—Send Calling Number field is y.
—Numbering Format field is Private.
—Send Connected Number field is y.
6. On each remote switch, repeat steps 3-5.
7. On each DEFINITY switch in the network, enter change dialplan on the 
command line of your system administration screen.
8. Administer the dial plan for each node in the network (see Chapter 4 in...

Page 159

What’s New in DEFINITY ECS
Release 8.2 Job Aid  555-233-754  Issue 1
April 2000
Networking Enhancements 
153 Networking - ISDN Private 
2
14. For each DEFINITY node, enter change isdn private-numbering, and 
verify fields as follows:
15.
Set Network Level field is 0
This setting  overrid es the sig naling  on the D c hannel, allowing  the 
Messag e Waiting  lamp  ac tivation sig nal to b e sent
16. On the DEFINITY node, enter change sys params mode-code on the 
command line. 
17. On the hub switch, set...

Page 160

What’s New in DEFINITY ECS
Release 8.2 Job Aid  555-233-754  Issue 1
April 2000
Networking Enhancements 
154 Networking - ISDN Private 
2
—
Distinctive Audible Alert field is n
.
—
Switchhook Flash field is y
.
—
LW C Activation field is y
.
24. For each remote DEFINITY node, enter change coverage remote on the 
command line. 
25. Administer or verify the following:
— 01 contains the extension of the voice mail hunt group.
Support for Japan National Private Networking
In release R8, DEFINITYs...