DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-37 G3V2 Administration 6 IXCValues: A valid three d ig it interexc hang e c arrier c od e or b lank. Re f e re n c e : Se c t io n ‘‘Network Sp ec ific Fac ilities IE in U.S.’’ in Chap ter 5, ‘‘Layers 2 and 3’’. This field ap p lies only to ISDN PRI trunk g roup s. Enter the c od e of the long d istanc e c arrier you want to c arry c alls in this...
Page 212
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-38 G3V2 Administration 6 TSC G3V2-only Values: yes no Re f e re n c e : Se c t io n ‘‘Temp orary Sig naling Connec tions’’ in Chapter 5, ‘‘Layers 2 and 3’’. If this trunk g roup is to b e used for tand eming or estab lishing TSCs, enter yes . CA-TSC Req ue stG3V2-only Values: as-needed at-setup Re f e re n c e : Se c t io n ‘‘Temp orary Sig...
Page 213
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-39 G3V2 Administration 6 ITC G3V2-only Values: res unr both Re f e re n c e : Se c t io n s ‘‘Bearer Capability IE’’ and‘‘Low Layer Comp atib ility IE’’ in Chap ter 5, ‘‘Layers 2 and 3’’. This field ap pears only if one or more of the field s in BCC is y . The ITC of the orig inating end p oint, whic h c an b e an ISDN or DCP d ata mod ule, is c...
Page 214
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-40 G3V2 Administration 6 CPN Prefix Table Form Settings This form allows you to d ec id e whic h extensions will b e used to send c alling p arty and /or c onnec ted p arty numb er for ISDN PRI c alls. The following list d esc rib es the ad ministration setting s for the ISDN PRI-sp ec ific field s in this ad ministration form. For more...
Page 215
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-41 G3V2 Administration 6 Terminating Extension Group Form Settings The only field on this sc reen ap p lic ab le to ISDN PRI is the ISDN Caller Display field. You must enter either grp-name or mbr-name to sp ec ify whether the TEG g roup name or memb er name is sent to the orig inating user when a memb er of a TEG answers. Ex t C o d e...
Page 216
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-42 G2.2 Administration 6 Hunt Group Form Settings The only field on this sc reen ap p lic ab le to ISDN PRI is the ISDN Caller Display field. You must enter either grp-name or mbr-name to sp ec ify whether the hunt g roup name or member name is sent to the far end when a memb er of a hunt group answers. G2.2 Administration The following sec...
Page 217
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-43 G2.2 Administration 6 nProc ed ure 100 Word 1: Trunk Group Typ e Sig naling and Dial Ac c ess (ID) Code nProc ed ure 100 Word 2: Trunk Group Data Translations nProc ed ure 100 Word 3: ISDN Trunk Group Sig naling Op tions nProc ed ure 101 Word 1: ISDN Trunk Group , CDR, and Dig ital Loss Plan nProc ed ure 101 Word 3: Prefix Dig its nProc...
Page 218
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-44 G2.2 Administration 6 Procedure 276 Word 1: Other Feature Groups Use this p roc ed ure to turn on op tional networking features suc h as AAR, DCS, SNC, Look-Ahead Interflow, and Integ rated Telemarketing Gateway (ITG) or to see whic h of these features are turned on. Procedure 250 Word 1: SC/DS1 — Carrier Designation This p roc ed ure is used...
Page 219
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-45 G2.2 Administration 6 Dep end ing on whether the p urp ose for translating this proc ed ure is to assig n the SC or to assig n a DS1 p ort c arrier will d etermine whic h enc ode to selec t. Fields 5-10 DS1/DMI/ISDN-PRI d oes not p lac e any ad d itional req uirements on translating these field s. Field 11 Field encodes and their descriptions...
Page 220
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-46 G2.2 Administration 6 Notes: 1. The c irc uit p ac k app lic ation typ e (Field 14) will to a larg e d eg ree d etermine whic h slots may be used . 2. When a DS1/MFAT c arrier is c onfig ured with two DS1s, p hysic al slots 3, 8, 16, and 21 are availab le for other ap p lic ations. If only one DS1 is c onfig ured , then six ad d itional slots...