DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-27 G3V2 Administration 6 Wideband Su p p o r tThis field ap pears only if wid eb and sup port is ad ministered in the system p arameters-c ustomer op tions form. For tec hnic al information on wid eb and switc hing in DEFINITY systems, refer to AT&T DEFINITY Wideb and Tec hnic al Referenc e, issue 1, 555-230-230. NCA-TSC Sig naling Group...
Page 202
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-28 G3V2 Administration 6 The following list d esc rib es the ad ministration setting s for the ISDN PRI-sp ec ific field s in the inc oming c all hand ling tab le p ortion of this ad ministration: The inc oming c all hand ling tab le, whic h ad ministers inc oming c all hand ling and d ig it manip ulation for ISDN PRI trunk g roup s, ap p...
Page 203
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-29 G3V2 Administration 6 nInc oming ACCUNET Switc hed Dig ital Servic es c alls to extensions 5008, 5009, and 5010-5029 will all b e routed to extension 5199. This extension mig ht, for examp le, b e the extension of a hunt g roup c ontaining d ata mod ules as endp oints. nAll MEGACOM 800 servic e c alls to extension 5119 will b e routed to...
Page 204
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-30 G3V2 Administration 6 Called Numb erValues: A numb er from 1 to 16 d ig its in length. Default is blank. This field allows you to spec ify the leading d ig its on inc oming c alls that you want to matc h. The d ig its sp ec ified in this field must exac tly matc h the lead ing d ig its c ontained in the Called Party Numb er IE of an inc...
Page 205
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-31 G3V2 Administration 6 Page 3 — Trunk Group Form — Usage Allocation Plan Page 3 of the trunk g roup form is the usag e alloc ation p lan for c all b y c all trunk g roup s. Following is an example of this showing the ISDN PRI-sp ec ific field s when the G3V2 is c onnec ted to a 4ESS vi a I SD N PRI : Pe r C a ll CPN/BN Values: b n-only...
Page 206
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-32 G3V2 Administration 6 For more d etails on interp reting the usag e alloc ation p lan, see the sec tion ‘‘Call b y C a l l Se r vi c e Se le c t io n i n G 3 V2 Sys t e m s’’ in Chap ter 5, ‘‘Layers 2 and 3’’. This sample sc reen shows two d ifferent usag e alloc ation plans for c alls on a c all-b y-c all trunk g roup using three network...
Page 207
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-33 G3V2 Administration 6 Notice that plan 2, which probably would be scheduled for after hours to do bulk d ata transfers with ACCUNET SDS servic e, g ives muc h hig her p riority to the ACCUNET c alls than d id p lan 1. Page 4 Trunk Group Screen—Usage Allocation Plan Assignment Schedule Following is an examp le of this sc reen showing the ISDN...
Page 208
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-34 G3V2 Administration 6 The following list d esc rib es the ad ministration setting s for the ISDN PRI-sp ec ific field s in this administration form: Fix ed , Sc hed uled Values: yes no (d efault) En t e r y in the Fixed field and n in the Scheduled field if you want a sing le p lan to be in effec t at all times. If you want d ifferent...
Page 209
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-35 G3V2 Administration 6 Wideband Support Options Page (G3V2-only) This page appears if wideband support field is set to yes. This page is either p age 3 or 5 d ep end ing on whether the usag e alloc ation p lan is administered . For tec hnic al information on wid eb and switc hing in DEFINITY systems, refer to AT& T DEFINITY Wid eb and Tec hnic...
Page 210
DEFINITY Communications System Generic 2.2 and Generic 3 V2 DS1/CEPT1/ISDN PRI Reference 555-025-107 Issue 1 July 1993 System Administration Page 6-36 G3V2 Administration 6 Pages 5 - on — Trunk Group Form — Group Member Assignment Assig ning memb ers to trunk g roup s is the same for ISDN PRI trunks as for any other with the exc ep tion that in G3V2 systems, the sig naling group must b e entered for eac h memb er unless all memb ers of a DS1/CEPT1 b oard are in the same signaling group. For...