Page 21
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Preparing for Installation and Upgrades 1-3 Review Configuration and Equipment 1 Review Configuration and Equipment Figure 1-1 shows and examp le of the b asic ATM c onnec tions for Release 8r and Release 8c si system using ATM-PNC and ATM-CES. For more d etailed c onnec tion d iag rams of the reliab ility op tions, refer to ‘‘DEFINITY ECS configurations’’ on page 1-6. Figure Notes Figure...
Page 22
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Preparing for Installation and Upgrades 1-4 Review Configuration and Equipment 1 Required Hardware Table 1-1 lists the req uired eq uip ment for stand ard , high, c ritic al reliab ility, and ATM network d up lic ation c onfig urations. To test the sync hronization sp litters, you need the following eq uip ment: nPhoenix 1541C Test Set with ac c essory c ord kit nPhoenix 5575A T1 Test Set with...
Page 23
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Preparing for Installation and Upgrades 1-5 Review Configuration and Equipment 1 nRJ45-to-Bantam test c ab le from the 1541CC c ab le kit nSystem capacities Table 1-2 lists the maximum numb er of TN2305/TN2306 c irc uit p ac ks allowed in a DEFINITY ECS. Table 1-2. Maximum number of ATM interface TN2305/TN2306 circuit packs PlatformMaximum ATM circuit packs allowed Description r 176 2 x 44 port...
Page 24
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Preparing for Installation and Upgrades 1-6 Review Configuration and Equipment 1 DEFINITY ECS configurations Figure 1-2, Figure 1-3, and Figure 1-4 show the ATM-PNC c onnec tions for stand ard , hig h, and c ritic al reliab ility, resp ec tively. Figure 1-2. ATM-PNC connections for standard reliability Figure Notes 1. Pub lic switc hed telep hone network (PSTN) 2. Main d istrib ution frame...
Page 25
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Preparing for Installation and Upgrades 1-7 Review Configuration and Equipment 1 Figure 1-3. ATM-PNC connections for high reliability Figure Notes 1. Pub lic switc hed telep hone network (PSTN) 2. Main d istrib ution frame (MDF) or smart jac k 3. Sync hronization splitter 4. DS1 c irc uit p ac k (TN464F) 5. TN2305/TN2306 c irc uit pac ks 6. DEFINITY ECS ac c ess terminal 7. Timing signal from sync...
Page 26
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Preparing for Installation and Upgrades 1-8 Review Configuration and Equipment 1 Figure 1-4. ATM-PNC connections for critical reliability or ATM network duplication Figure Notes 1. Pub lic switc hed telep hone network (PSTN) 2. Main d istrib ution frame (MDF) or smart jac k 3. Sync hronization splitter 4. DS1 c irc uit p ac k (TN464F) 5. TN2305/TN2306 c irc uit pac ks 6. DEFINITY ECS ac c ess...
Page 27
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Preparing for Installation and Upgrades 1-9 Determine ATM Switch Suitability 1 Determine ATM Switch Suitability To fully sup p ort DEFINITY ATM-PNC and provid e nonb loc king ATM ac c ess b etween all p ort networks, ATM switc hes must supp ort at least 400 p oint-to-multip oint switc hed virtual c onnec tion (SVC) roots or leaves p er OC-3/STM-1 interfac e. Bec ause d ifferent switc hes have d...
Page 28
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Preparing for Installation and Upgrades 1-10 Determine ATM Switch Suitability 1 Figure 1-3 shows an example of a calculation. PROBABLY means that this application is okay under any reasonable loads. Check the constraint tests results to see what kind of loads might be a problem. YES means that this application is okay under any load. NO means that this ap p lic ation is not reasonab le. See the...
Page 29
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Preparing for Installation and Upgrades 1-11 Determine ATM Switch Suitability 1 UNKNOWN means that sp ec ial eng ineering is req uired for this ap p lic ation b ec ause of the transit traffic . The sp ec ial treatment is nec essary b ec ause the feasib ility d ep end s on the volume of the transit traffic . Making any of the c hang es sug g ested for NO ab ove mig ht make it feasib le reg...
Page 30
DEFINITY ECS Release 8.2 ATM Installation, Upgrades, and Administration 555-233-124 Issue 1 April 2000 Preparing for Installation and Upgrades 1-12 Determine ATM Switch Suitability 1 Final notes The g oal is to engineer the network so that in all reasonab le app lic ations, you always run out of DEFINITY time slots before running out of ATM switc h resourc es. This is req uired to p rovid e ac c ep table servic e to the c ustomer. These calculations factor in phone calls only. There is no...