Page 1291
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Features and technical reference 1267 Call Detail Recording 20 6 (E) Identifies calls that are not recorded because of resource exhaustion. A record with this condition code is generated for calls that are routed to the attendant or calls that require CDR to overwrite records. This also includes ISDN calls that did not complete at the far end, for which the Q.931 message included a cause value. It does not include ISDN...
Page 1292
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Features and technical reference 1268 Call Detail Recording 20 If the trunk-group CDR Reports field is set to ring, CDR records the ring time to answer or abandon for incoming calls originated by the trunk group. In addition, CDR indicates if the incoming destination is busy. This record is separate from the normal call duration record printed for an answered call. This information is indicated by the condition code....
Page 1293
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Features and technical reference 1269 Call Detail Recording 20 Table 46. Condition Code Override Matrix CONDITION CODE 0146789ABCEFJK 0N A0460N AN AN ABCN AN AN AN A 10 N A461N A91BCEN AJK 444N A6444444N AN AJK 6666N A6666666666 70146N A797BCEFJ K 8N AN A467N AN A8BCEN AN AK 9N A9469N AN AN AN ACE F N AN A AN A14678N AN ABCE F N AN A BBB4 6 BBN ABN ABE F N AK CCC4 6 CCCCBN AN AN AJK EN AEN A6 EEEEEN AN AN AEE FN AN AN...
Page 1294
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Features and technical reference 1270 Call Detail Recording 20 nDate You can include the date in customized records only. The format is based on the value of the CDR Date Format field on the CDR System Parameters form. nDialed Number (dialed-num) — up to 23 digits This field contains the number dialed. If it is an outgoing call, the field contains the number dialed by a system user. If it is an incoming call, the field...
Page 1295
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Features and technical reference 1271 Call Detail Recording 20 nFeature Flag (feat-flag) — 1 digit The feature flag indicates whether a call received network answer supervision, and if the call was interworked in the network. The call duration starts at the point of receiving the network answer. You can administer the feature flag (on the CDR System Parameters form) to reflect whether an outgoing ISDN call was reported...
Page 1296
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Features and technical reference 1272 Call Detail Recording 20 — If the call is an outgoing call and an authorization code is used to make the call, this field contains the FRL associated with the dialed authorization code. — If the call is an incoming or tandem call, this field contains the FRL assigned to the incoming trunk group. — If the call is an incoming tandem tie trunk call, this field contains either the FRL...
Page 1297
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Features and technical reference 1273 Call Detail Recording 20 nINS (3 digits) This field specifies the ISDN Network Service requested for a call. This field applies only to ISDN calls. Each Network Specific Facility has a corresponding INS value, shown in Table 47 . This field also appears as ISDN NSV (Network Service Value). nISDN CC The call charge supplied by the ISDN advice of charge function (see ‘‘ Receiving...
Page 1298
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Features and technical reference 1274 Call Detail Recording 20 Users must dial an IXC access number to access a specific common carrier for a call. In the US, this number is in the form 10XXX, 950 — 1XXX, or any 8–11 digit number. The IXC access numbers applicable at a given location are associated with an IXC code on the Inter-Exchange Carrier Codes form. When ARS is used, and a route pattern inserts one of the...
Page 1299
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Features and technical reference 1275 Call Detail Recording 20 The format of this field varies from record to record. For printer, Teleseer and 59-character formats, and the ISDN and enhanced forms of those records, the numbers appear inverted on the record. For example, the circuit ID 123 appears as 231 (tens, units, hundreds). If you want to change this to appear in hundreds, tens, units format (123), use the...
Page 1300
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Features and technical reference 1276 Call Detail Recording 20 Table 48. Encoding for TSC Flag Encoding Meaning 0 Circuit-switched call without TSC requests 1–3 Reserved 4 Call Associated TSC requested and accepted in response to SETUP, no congestion control (applicable to originating node). Call Associated TSC received and accepted via SETUP, no congestion control (applicable to terminating node). 5 Call Associated...