Page 1051
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 1027 Trunk Group 17 Outgoing Seizure (msec) Appears when the Country field is 15, the Direction field is outgoing or two-way, and the Trunk Type field is 2-wire-ac, 2-wire-dc, or 3-wire. This timer is sent only to the TN2199 circuit pack. Incoming Incomplete Dial Alarm (sec) Only the TN436 (all), TN459 (all), TN464C (or later), TN767, TN2140, TN2146, TN2184, TN2199, and TN2242 circuit packs use this...
Page 1052
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 1028 Trunk Group 17 Normal Outgoing Seize Send (msec) This field appears only if the Trunk Signaling Type field is dis and the trunk group Direction field is two-way or outgoing. Only TN2140 ports receive this timer. Release Ack Send (msec) After your switch receives a forward release signal, it must send a forward release acknowledgment signal. This field appears only if the Trunk Signaling Type...
Page 1053
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 1029 Trunk Group 17 Outgoing Disconnect Send (msec) This field is administrable only if the Trunk Signaling Type field is dis and the trunk group Direction field is two-way or outgoing. Only TN2140 ports receive this timer. Seize Ack Send (msec) This field appears only if the Trunk Signaling Type field is dis and the trunk group Direction field is incoming or two-way. Only TN2140 ports receive this...
Page 1054
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 1030 Trunk Group 17 Pause (msec) THis field is administrable only if the Trunk Signaling Type field is blank. All CO, DIOD, and tie circuit packs that accept administrable timers accept this timer. However, this timer is sent only to the following circuit packs: TN464B (or later), TN767, TN436B, TN459B, TN2146, TN2199, and TN2242, and TN429 and TN2184 ports in a DID trunk group. PPS NOTE: The TN439,...
Page 1055
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 1031 Trunk Group 17 Break (msec) PPM For CO, DIOD, FX, PCOL, and WATS trunks. This field appears when the Direction field is outgoing or two-way. Frequency This field identifies the PPM pulse frequency(ies) sent by the public network. It appears if the Direction field is outgoing or two-way and PPM is y. Circuit packs can detect up to three different frequencies, (12kHz, 16kHz, and 50Hz), plus two...
Page 1056
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 1032 Trunk Group 17 Field descriptions for page 4 This screen appears when the Direction field on Page 1 is outgoing or two-way and the ATMS field is y on the Feature-Related System Parameters screen. The figure below shows a common configuration for page 4 of the Trunk Group screen when the Group Type field is co. This screen is only an example, and the fields shown below may change or disappear...
Page 1057
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 1033 Trunk Group 17 TTL Type Specifies the type of terminating test line (TTL) selected for testing trunks. The TTL type determines what ATMS tests can be completed and thus which threshold values need to be administered. The following table explains the differences between types of terminating test lines: Valid entries Usage 105-w-rl 105 with return loss 105-wo-rl105 without return loss...
Page 1058
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 1034 Trunk Group 17 The far-end switch containing the TTL may be any of the following: nSystem 85 R2 switch, equipped with the Maintenance/Test Board (TN771B) nSystem 75 R1V2 and beyond, all of which contain the circuitry required to perform the TTL function nSystem 85 R2 switch, equipped with the Analog/Digital Facility Test Circuit (ADFTC, SN261) nDIMENSION FP8, equipped with the Analog Facility Test...
Page 1059
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 1035 Trunk Group 17 TTL Contact Trunk Vendor Trunk Contact Trunk Length This field is not required. Since noise on a trunk increases with the length of the trunk, however, this information may be useful, Marginal Threshold - Min -1004 Hz Loss Valid entries Usage 0 to 25 alphanumeric characters Enter the name and/or telephone number of someone from the TTL vendor who can be contacted in the event of...
Page 1060
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 1036 Trunk Group 17 Marginal Threshold - Max - 1004 Hz Loss Unacceptable Threshold - Min - 1004 Hz Loss Unacceptable Threshold - Max - 1004 Hz Loss Marginal Threshold - -Dev - 404 Hz Loss Marginal Threshold - +Dev - 404 Hz Loss Valid entries Usage 0 to 21Enter the maximum signal loss allowed for a 1004 Hz test tone (in dB) before a trunk is reported as out of tolerance. A smaller dB value is more...