Page 881

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1
April 2000
Screen reference 
857 Remote Access 
17
H12
NXDS0
Contiguous
Specifies whether to hunt contiguous NXDS0 channels. This field only appears if 
y is entered in NXDS0. The hunt algorithm to satisfy an NXDS0 call is as follows:
Remote Access
The Remote Access screen is used to implement the Remote Access feature. 
Remote Access permits a caller located outside the system to access the system 
through the public or private network...

Page 882

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1
April 2000
Screen reference 
858 Remote Access 
17
!SECURITY ALERT:
Lucent Technologies designed the Remote Access feature incorporated in 
this product that, when properly administered by the customer, enables the 
customer to minimize the ability of unauthorized persons to gain access to 
the network. It is the customer’s responsibility to take the appropriate steps 
to properly implement the features, evaluate and administer the...

Page 883

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1
April 2000
Screen reference 
859 Remote Access 
17
!CAUTION:
Your attempt to disable the Remote Access feature will be lost if the switch is 
rebooted without saving translations. Therefore, execute a “save 
translation” command after permanently disabling the Remote Access 
feature.
To assist you in maintaining the security of your system, DEFINITY ECS 
provides the status remote access command, which provides status and 
information...

Page 884

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1
April 2000
Screen reference 
860 Remote Access 
17
Screen 176. Remote Access Status 
Remote Access Extension
The remote access extension is used as if it was a DID extension. Only one DID 
extension can be assigned as the remote access extension. Calls to that number are 
treated the same as calls on the remote access trunk.
When a trunk group is dedicated to Remote Access, the remote access extension 
number is administered on the...

Page 885

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1
April 2000
Screen reference 
861 Remote Access 
17
Authorization Code Required
When you use an authorization code in conjunction with a barrier codes it 
increases the security of the Remote Access feature.
Remote Access Dial Tone
Set this field to 
n for maximum security. This field appears when the 
Authorization Code Required field is set to y.
Barrier Code
You must assign a barrier code that conforms to the number entered in the...

Page 886

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1
April 2000
Screen reference 
862 Remote Access 
17
TN
COS
Assign the most restrictive class of service (COS), that provides only the level of 
service required to provide the maximum security.
Expiration Date
Assign an expiration date based on the expected length of time the barrier code 
will be needed. If it is expected the barrier code is to be used for a 2-week period, 
assign a date two weeks from the current date. If the...

Page 887

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1
April 2000
Screen reference 
863 Remote Call Coverage Table 
17
Permanently Disable
Reactivation of remote access to the interface requires Lucent Services 
intervention.
Disable Following a Security Violation
This field appears on the screen when the SVN Authorization Code Violation 
Notification Enabled field on the Security-Related System Parameters screen is 
set to y. 
Related Topics
Refer to ‘‘
Setting up remote access’’ on page...

Page 888

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1
April 2000
Screen reference 
864 RHNPA Table 
17
Field descriptions for page 1
Screen 177. Remote Call Coverage Table 
RHNPA Table
The RHNPA Table defines route patterns for specific 3-digit codes, usually direct 
distance dialing (DDD) prefix numbers. 
Screen 178. RHNPA Table
change coverage remote
REMOTE CALL COVERAGE TABLE
01: ________________      16: ________________      31: ________________        
02: ________________      17:...

Page 889

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1
April 2000
Screen reference 
865 Route Pattern 
17
RHNPA TABLE
CODE
Enter the desired 100-block, for example 000 through 099 or 900 through 999. A 
separate screen is required for each 100-block.
Pattern Choices
Code-Pattern Choice Assignments
Route Pattern
The Route Pattern screen defines the route patterns used by your switch. Each 
route pattern contains a list of trunk groups that can be used to route the call. The 
maximum number...

Page 890

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1
April 2000
Screen reference 
866 Route Pattern 
17
Screen 179. Route Pattern
Pattern Number
Displays the route pattern number (
1 to 640).
Grp No
FRL
!SECURITY ALERT:
For system security reasons, Lucent recommends using the most restrictive 
FRL possible.
Network Specific Facility
Identifies the services and features used to complete a call. 
Valid entries Usage
1
 to 99Enter the trunk group number associated with this row...