Page 881
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 857 Remote Access 17 H12 NXDS0 Contiguous Specifies whether to hunt contiguous NXDS0 channels. This field only appears if y is entered in NXDS0. The hunt algorithm to satisfy an NXDS0 call is as follows: Remote Access The Remote Access screen is used to implement the Remote Access feature. Remote Access permits a caller located outside the system to access the system through the public or private network...
Page 882
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 858 Remote Access 17 !SECURITY ALERT: Lucent Technologies designed the Remote Access feature incorporated in this product that, when properly administered by the customer, enables the customer to minimize the ability of unauthorized persons to gain access to the network. It is the customer’s responsibility to take the appropriate steps to properly implement the features, evaluate and administer the...
Page 883
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 859 Remote Access 17 !CAUTION: Your attempt to disable the Remote Access feature will be lost if the switch is rebooted without saving translations. Therefore, execute a “save translation” command after permanently disabling the Remote Access feature. To assist you in maintaining the security of your system, DEFINITY ECS provides the status remote access command, which provides status and information...
Page 884
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 860 Remote Access 17 Screen 176. Remote Access Status Remote Access Extension The remote access extension is used as if it was a DID extension. Only one DID extension can be assigned as the remote access extension. Calls to that number are treated the same as calls on the remote access trunk. When a trunk group is dedicated to Remote Access, the remote access extension number is administered on the...
Page 885
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 861 Remote Access 17 Authorization Code Required When you use an authorization code in conjunction with a barrier codes it increases the security of the Remote Access feature. Remote Access Dial Tone Set this field to n for maximum security. This field appears when the Authorization Code Required field is set to y. Barrier Code You must assign a barrier code that conforms to the number entered in the...
Page 886
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 862 Remote Access 17 TN COS Assign the most restrictive class of service (COS), that provides only the level of service required to provide the maximum security. Expiration Date Assign an expiration date based on the expected length of time the barrier code will be needed. If it is expected the barrier code is to be used for a 2-week period, assign a date two weeks from the current date. If the...
Page 887
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 863 Remote Call Coverage Table 17 Permanently Disable Reactivation of remote access to the interface requires Lucent Services intervention. Disable Following a Security Violation This field appears on the screen when the SVN Authorization Code Violation Notification Enabled field on the Security-Related System Parameters screen is set to y. Related Topics Refer to ‘‘ Setting up remote access’’ on page...
Page 888
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 864 RHNPA Table 17 Field descriptions for page 1 Screen 177. Remote Call Coverage Table RHNPA Table The RHNPA Table defines route patterns for specific 3-digit codes, usually direct distance dialing (DDD) prefix numbers. Screen 178. RHNPA Table change coverage remote REMOTE CALL COVERAGE TABLE 01: ________________ 16: ________________ 31: ________________ 02: ________________ 17:...
Page 889
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 865 Route Pattern 17 RHNPA TABLE CODE Enter the desired 100-block, for example 000 through 099 or 900 through 999. A separate screen is required for each 100-block. Pattern Choices Code-Pattern Choice Assignments Route Pattern The Route Pattern screen defines the route patterns used by your switch. Each route pattern contains a list of trunk groups that can be used to route the call. The maximum number...
Page 890
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 866 Route Pattern 17 Screen 179. Route Pattern Pattern Number Displays the route pattern number ( 1 to 640). Grp No FRL !SECURITY ALERT: For system security reasons, Lucent recommends using the most restrictive FRL possible. Network Specific Facility Identifies the services and features used to complete a call. Valid entries Usage 1 to 99Enter the trunk group number associated with this row...