Page 631
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 607 DS1 Circuit Pack 17 This field appears if the Signaling Mode field is CAS or isdn-pri. For the Japanese 2Mbit trunk circuit pack, this is a display-only field if the Signaling Mode field is CAS. Peer Protocol This allows you to administer the peer level protocol that will operate in a private network. This field appears if the Interface field is peer-master or peer-slave. To enter Q-SIG, the...
Page 632
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 608 DS1 Circuit Pack 17 The default value of the field changes depending upon which value the Interface field contains. !CAUTION: It is critical that administration on this switch correctly pairs with the administration of the far-end switch. If the far-end is administered as the b side, this field should be set to a regardless of whether the layer 2 designation is peer-master or peer-slave, and vice...
Page 633
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 609 DS1 Circuit Pack 17 Interface Companding The entry in this field must match the companding method used by the far-end switch. This field does not appear for all DS1 circuit packs. CRC This field indicates whether a cyclic redundancy check (CRC) will be performed on transmissions that the DS1 circuit pack receives. This field does not display for all circuit packs. Idle Code !CAUTION: Customers: The...
Page 634
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 610 DS1 Circuit Pack 17 This field appears when the Signaling Mode field is isdn-pri, the Bit Rate field is 2.048, the Connect field is pbx, and the Interface field is peer-master or peer-slave. DMI-BOS The DMI/BOS protocol is used for high-speed digital communications between a host computer and a DEFINITY ECS. With this 24-channel protocol, channels 1–23 of the DS1 link carry data and channel 24...
Page 635
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 611 DS1 Circuit Pack 17 MMI Interface This display-only field appears if the MMCH field is y on the System-Parameters Customer-Options screen and there is a value in the MMI Cabling Board field. Received Digital Metering Pulse Minimum (ms) This field appears only when the Signal Mode field is cas (Channel Associated Signaling), the Interconnect field is co or pbx, and the Country Protocol field is...
Page 636
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 612 DS1 Circuit Pack 17 Table 11. Incoming Digital PPM Signaling Default (per Country Protocol code) Code Country PPM Min (ms) PPM Max (ms) PPM Value 0 null NA NA NA 1U.S. NA NA NA 2 Australia 80 180 0 3 Japan NA NA NA 4 Italy 120 150 1 5 Netherlands 90 160 0 6 Singapore NA NA NA 7Mexico 20 180 1 8 Belgium 20 180 1 9 Saudi Arabia NA NA NA 10 UK NA NA NA 11 Spain 20 220 0 12 France NA NA NA 13 Germany NA NA...
Page 637
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 613 DS1 Circuit Pack 17 Slip Detection Slips — synchronization errors — slow digital transmissions and can result in data loss. The switch maintains a slip-count record for each DS1 interface to detect errors and evaluate their severity (the type of alarm). If as many as 50 percent of those spans administered for slip detection are experiencing slips (with respect to the primary), then a decision is...
Page 638
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 614 DS1 Circuit Pack 17 Alarm When PRI Endpoint Detached Use this field for DS1 circuit packs connected to Roll-About Video equipment. This field appears only when the Connect field is line-side. Field descriptions for page 2 Screen 76. DS1 Circuit Pack !CAUTION: Customers: Do not change fields on this page without assistance from Lucent Technologies or your network service provider. Page 2 does not...
Page 639
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 615 DS1 Circuit Pack 17 Network Management Protocol This field appears only if the Framing Mode field is esf. Send ANSI-T1.403 One-Second Performance Reports This field selects whether your DS1 circuit pack will send error reports to the far-end switch. These reports are useful for network management, and are sent at 1-second intervals when enabled. This field appears only if the Framing Mode field is...
Page 640
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 616 DS1 Circuit Pack 17 Receive ALBO (Receive Automatic Line Build-Out) This field increases the strength of incoming signals by a fixed amount to compensate for line losses. Upon DTE LOS DTE stands for “Data Terminal Equipment.” This field tells the switch what to do if the outgoing signal from the DS1 circuit pack (the data terminal equipment) to the network is lost. Supply CPE Loopback Jack Power...