Page 551
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 527 Class of Restriction 17 Fully Restricted Service NOTE: If this field is enabled, the APLT field must be n. Category For MFC ANI The Category for MFC ANI field always controls categories for Russian signaling trunks. It also may control categories for R2-MFC signaling trunks, depending on what value is in the Use COR for Calling Party Category field on the system-parameters multi-frequency screen. The...
Page 552
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 528 Class of Restriction 17 Add/Remove Agent Skills MF ANI Prefix Defines the prefix to apply to an extension number when ANI is sent to the CO. This overrides any ANI prefix administered on the Multifrequency Signaling screen. This does not apply when ANI is tandemed through the switch on tandem calls. This field also applies to the ANI for the switch when the originating side is a trunk and there was...
Page 553
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 529 Class of Restriction 17 Automatic Charge Display Shows the cost of an active outgoing call using Periodic Pulse Metering (PPM) or ISDN Advice of Charge (AOC) on Digital Communications Protocol (DCP) or Lucent BRI stations. Can Be Picked Up By Directed Call Pickup Can Use Directed Call Pickup Group Controlled Restriction Determines if the current COR is under controlled restriction. This field can help...
Page 554
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 530 Class of Restriction 17 Field descriptions for page 2 Screen 50. Class of Restriction screen MF Incoming Call Trace Brazil Collect Call Blocking For Brazil only Block Transfer Display Valid entries Usage y/n Enter y to allow assignment of a Call Trace COR to a station. DEFINITY ECS then generates an MFC backward signal (administered on the System-Parameters Multifrequency-Signaling screen) during...
Page 555
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 531 Class of Restriction 17 Field descriptions for page 3 Screen 51. Class of Restriction screen CALLING PERMISSION Field descriptions for page 4 Screen 52. Class of Restriction Valid entries Usage y/n A y means an originating facility assigned this COR can be used to call facilities assigned this COR. Enter n for each COR number (0 through 95) that cannot be called by the COR being implemented. change...
Page 556
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 532 Class of Service 17 SERVICE OBSERVING PERMISSION Class of Service This screen administers access permissions for call processing features that require dial code or feature button access. NOTE: Class of Service (COS) does not apply to trunk groups except for the Remote Access feature. A COS assignment defines whether or not a telephone user may access or use the following features and functions. Up to...
Page 557
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 533 Class of Service 17 The screen lists the default values for each COS/feature combination. For a particular combination, y allows access to the feature and n denies access. Assign entries on the screen for each COS to be implemented. Default values are shown on the screen. !CAUTION: Because many hunt groups are set up with COS 1, be careful when you assign restrictions to COS 1. Automatic Callback...
Page 558
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 534 Class of Service 17 nAdd and remove agent skills nRecord integrated announcements Off-Hook Alert See ‘‘ Emergency Access to the Attendant’’ on page 1323 for more information. To enable this option, either the Hospitality (Basic) or Emergency Access to Attendant field must be enabled on the System-Parameters Customer-Options screen. Client Room Allows users to access Check-In, Check-Out, Room...
Page 559
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 535 Code Calling IDs 17 Extended Forwarding B/DA Allows this user to administer call forwarding (when the dialed extension is busy or does not answer) from a remote location. You cannot change this COS to y if Extended Cvg/Fwd Admin on the System Parameters Customer-Options screen is n. See ‘‘Extended User Administration of Redirected Calls’’ on page 1213 for more information. Trk-to-Trk Restriction...
Page 560
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1 April 2000 Screen reference 536 Command Permission Categories 17 Screen 54. Code Calling IDs Ext This field assigns extensions to chime codes. Only one extension can be assigned to each chime code. Related topics Refer to ‘‘ Setting up chime paging over loudspeakers’’ on page 378 for instructions. Refer to ‘‘ Loudspeaker paging’’ on page 1416 for a description of the feature. Command Permission Categories Use this screen to...