Page 191

DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
May 1999
Ongoing Administration 
10-21 Ongoing Subscriber Administration 
10
4. Ask the system ad ministrator at the remote system to c hang e the remote 
system to allow upd ates to and /or from the remote system.
5. At enter command:
 on the loc al DEFINITY AUDIX ad ministration 
terminal, enter get remote-updates
 
machine name (name of the remote 
system) and  p ress  
to c op y all remote sub sc rib ers to the loc al 
DEFINITY AUDIX...

Page 192

DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
May 1999
Ongoing Administration 
10-22 Ongoing Subscriber Administration 
10
7. When the remote up d ates p roc ed ure has c omp leted , d o the following :
a. With the c ursor at enter command:
, enter list remote extensions 
and  p ress  . Chec k to see that the remote sub sc rib ers are on 
the loc al DEFINITY AUDIX system.
b. Enter list measurements feature day
 and press  
to d isp lay 
the Feature Daily Traffic  sc reen. Verify the new...

Page 193

DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
May 1999
Ongoing Administration 
10-23 Ongoing Subscriber Administration 
10
1. At enter command:
 on the loc al DEFINITY AUDIX ad ministration 
terminal, enter add remote-subscriber
 and press  
to display the 
Remote Sub sc rib er sc reen similar to the sc reen shown b elow. 
Figure 10-10. Add Remote Subscriber Screen    
2. Enter the remote sub sc rib er name in the Name field .
3. Enter the extension of the remote sub sc rib er in the...

Page 194

DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
May 1999
Ongoing Administration 
10-24 Ongoing Subscriber Administration 
10
6. The Voic ed Name, Non-Ad ministered  Typ e, and  Last Usag e Date field s 
are display only. You cannot change the information in the fields. 
The Voiced Name field c ontains a y
 when a name has b een rec ord ed  for 
the remote subsc riber. If no name is rec ord ed , the field  c ontains an n
. 
When the system send s a messag e to a non-ad ministered  verified...

Page 195

DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
May 1999
Ongoing Administration 
10-25 Ongoing Subscriber Administration 
10
Manually Updating Remote Subscriber
Administration
The instruc tions in this sec tion exp lain how to up date remote sub sc rib er 
information. If you d ec id e not to use the remote up d ates feature, you must 
manually up d ate remote sub sc rib er information if the information c hanges. Even 
if you d o use the remote up d ates feature, you may need  to c hang e...

Page 196

DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
May 1999
Ongoing Administration 
10-26 Ongoing Subscriber Administration 
10
2. Use   or   to move the c ursor to the field you need to change and 
up d ate the information. You c an c hang e the value in any field  exc ep t the 
Ad d ress, Voic ed  Name, and  Non-Ad ministered  Typ e field s. These fields 
are display only. 
The Voiced Name field c ontains a y
 when a name has b een rec ord ed  for 
the remote subsc riber. If no name is rec...

Page 197

DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
May 1999
Ongoing Administration 
10-27 Ongoing Subscriber Administration 
10
Use the following  instruc tions to d elete remote sub sc rib er information.
1. At enter command:
 on the loc al DEFINITY AUDIX ad ministration 
terminal, enter remove remote-subscriber
 
extension and  p ress   
to d isp lay the Remote Sub sc rib er sc reen for the extension number 
entered , similar to the sc reen shown b elow.
Figure 10-12. Delete Remote...

Page 198

DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
May 1999
Ongoing Administration 
10-28 Ongoing Subscriber Administration 
10
Recording Remote Subscriber Names
After you ad minister the remote sub sc ribers, you need  to rec ord  the sub sc ribers’ 
names. The DEFINITY AUDIX system d oes not req uire you to rec ord  remote 
sub sc rib er names, b ut the feature provid es a friendly c onfirmation for c allers 
when they ad d ress voic e messag es to remote sub sc rib ers. 
On the System...

Page 199

DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
May 1999
Ongoing Administration 
10-29 Ongoing Subscriber Administration 
10
8. Press   to ed it the rec ord ing , or p ress  
to approve the rec ording.
nIf you p ress   to stop  rec ord ing , you hear the following  p romp t:
To ap prove, p ress  . To rec ord  from here, press  . To p lay b ac k, 
p ress 
 . 
Before you app rove the rec ord ing , you have the following  op tions:
— Press     to listen to the remote sub sc rib er name 
rec...

Page 200

DEFINITY AUDIX System Digital Networking  585-300-534  Issue 2
May 1999
Ongoing Administration 
10-30 Ongoing Subscriber Administration 
10 
Start reading Lucent Technologies Definity Audix System Digital Networking Guide