Page 31
Page 2-1 Installation ENCORE MANUAL, Issue 4.0 – July 2002 INSTALLATION 2Installation CONTENTS PAGE 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 2. System Installation Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 3. Planning the Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 A. Establish Suitable...
Page 32
Page 2-2 Installation ENCORE MANUAL, Issue 4.0 – July 2002 Introduction 1. INTRODUCTION 1.1This section of the manual describes specifications and installation for the following Encore System hardware: •Cabling and the Main Distribution Frame (MDF) •Key Service Unit (KSU) •Keysets and Single-Line Sets •Optional Equipment NOTICE This Inter-Tel Encore Installation, Programming, and Maintenance Manual instructs certi- fied field technicians on the proper installation practices for the Encore System. This...
Page 33
Page 2-3 Installation ENCORE MANUAL, Issue 4.0 – July 2002 System Installation Checklist INSTALLATION 2 2. SYSTEM INSTALLATION CHECKLIST 2.1System installation is performed in the following order. Detailed instructions and fig- ures for each step are located throughout this chapter. !Read the safety and precaution information on page xvii. !Plan the installation, including the Key Service Unit (KSU) location, Keyset and single- line set locations, cable runs, and optional equipment. See page 2-4 for...
Page 34
Page 2-4 Installation ENCORE MANUAL, Issue 4.0 – July 2002 Planning the Installation 3. PLANNING THE INSTALLATION 3.1To make installation easier, use the following information when preparing to install the system. A. ESTABLISH SUITABLE ENVIRONMENTAL CONDITIONS FOR THE SYSTEM Location 3.2The KSU is intended for installation in a residential or office-type environment. It must be mounted on a dry, flat wall. 3.3Select the KSU location to minimize cable run length. Keysets and single-line sets con- nected...
Page 35
Page 2-5 Installation ENCORE MANUAL, Issue 4.0 – July 2002 Establish Suitable Environmental Conditions for the System INSTALLATION 2 Supervised CO Lines 3.8Only supervised CO lines should be used on the Encore System. While the system has timers that will help to prevent unsupervised trunk use, there is no implied warranty that it is invulnerable to unauthorized intrusions and toll fraud. 3.9If the central office does not provide supervision it will not disconnect the call when one party hangs up; it is...
Page 36
Page 2-6 Installation ENCORE MANUAL, Issue 4.0 – July 2002 Assemble the Necessary Tools and Supplies B. ASSEMBLE THE NECESSARY TOOLS AND SUPPLIES 3.13You will need the following supplies and tools: •Industry-standard, two-pair (four-conductor), twisted-pair cable to run from the KSU to Keysets, single-line sets, and CO lines •One or two 66M1-50-type block connectors •Four-conductor modular jack assemblies for Keysets and single-line sets •A high-impedance digital multimeter to check the correct wiring of...
Page 37
Page 2-7 Installation ENCORE MANUAL, Issue 4.0 – July 2002 Extension and CO Line Cabling INSTALLATION 2 4. EXTENSION AND CO LINE CABLING 4.1Prepare a floor plan for the Keyset and single-line set locations, using a star (home run) configuration. Include each telephone’s extension number. Extension number 20 is assigned to the system operator. A. RUNNING CABLE 4.2A 25-pair cable is run from the CO lines and extensions and terminated on a 66M1-50- type connecting block that is wall-mounted near the KSU....
Page 38
Page 2-8 Installation ENCORE MANUAL, Issue 4.0 – July 2002 Sample System Layout B. SAMPLE SYSTEM LAYOUT 4.3The diagram below shows a suggested layout for the KSU and block(s). You will need two blocks if Expansion cards are installed. Figure 2-1.Sample Layout and Cable Assignments Encore CONNECTING BLOCKS Cable B to Expansion Cards Cable A to CPU To Extensions 26-37 on Expansion Card To Extensions 20-25 and devices on CPU To Te l c o (enters through side) (enters through bottom) (Use...
Page 39
Page 2-9 Installation ENCORE MANUAL, Issue 4.0 – July 2002 Terminating the Cables at Extension Locations INSTALLATION 2 C. TERMINATING THE CABLES AT EXTENSION LOCATIONS 4.4Terminate the keyset and single-line set cables on four-conductor modular jack assem- blies at the extension location, as shown in the diagram below. Refer to the figure below for a wiring diagram. NOTE: It is recommended that four-conductor modular jacks be used for all Keyset and single- line set connections. This allows both types...
Page 40
Page 2-10 Installation ENCORE MANUAL, Issue 4.0 – July 2002 Wiring for Operation During Power Failure Conditions E. WIRING FOR OPERATION DURING POWER FAILURE CONDITIONS 4.7When planning the extension wiring for the system, consideration should be given to the use of Keysets and single-line telephones in power-fail situations. As Keysets cannot oper- ate without power, Extensions 24, 25, 31 and 37 should either have access to or be equipped with single-line sets if they are to be used in power failure...