Accenta/Optima Engineer’s Manual
27
Timers (cont’d)
LED Keypad:
To change the Rearm Count:
.
•Press [7] to enter Set Up Timers.LED’s 1, 2 and 3 are on.
•Press [3] for Rearm Count. LED 1 is on.
•Select a number [0 - 9] to change the rearm count.
•To accept the change press [SET].  LED’s 1, 2 and 3 are
on. Press [RESET].
OR to cancel the change press the [RESET] button twice.
73 = Set Up Rearm Count
After an alarm the panel will automatically rearm itself when the external siren (Bell) timer has expired....

Page 32

Accenta/Optima Engineer’s Manual
28
To change the other codes: Press the [up arrow] to move through the codes.
[2] = User 2
[3] = Duress
[4] = Engineer LCD Keypad:
To change User code:
• Press the [8] button on the keypad or press the
[up arrow] for Set Up Codes. Then press [SET].
• Press the [1] or [SET] button on the keypad to
edit user code.
• Enter the new [4-digit code].
• Upon the last keypress the code is saved.
8 = Set Up Codes
There are four codes used in the system, all are 4 digit and can be...

Page 33

Accenta/Optima Engineer’s Manual
29
Codes (cont’d)
LED Keypad:
To change User code:
• Press [8] to edit user code. LED’s 1-4 are on.
• Press [1] or [SET] to edit user code 1. LED’s 1-4 are on.
• Enter the new 4-digit code.
• Upon the last keypress the new code is saved.
• To leave menu press [RESET] twice.
The other codes are changed in a similar manner from step 2;
Press [2] for User 2
Press [3] for Duress code
Press [4] for Engineer code.
NOTE:To delete the 4-digit code from User 2 or Duress, enter...

Page 34

Accenta/Optima Engineer’s Manual
30
C = View Event Log
1 = LCD Keypad:
The event log gives a display of all the events that have taken place. The events are arranged by date and time.
Up to 250 events can be stored in the memory. When the log reaches 250 events and another event takes
place, the first event drops out. The system is known as FILO (First In Last Out).
To view the event log:
• Press the [up arrow] until you come to the first screen.
• Press [CHIME] or [SET] .
• Choose [1] for Event Log in...

Page 35

Accenta/Optima Engineer’s Manual
31
2 = LED Keypad:
The LED keypad is limited to show the last eight set periods with the eighth being the oldest. Zone, PA and
Tamper indicators will be lit to show zone in alarm . Flashing LED indicates the first zone in alarm. Day indi-
cates the status of the panel at the time of the alarm.
O = Omit Allow and Double Knock
1 = Double Knock
Double knock programming is used when zones are likely to create false activations. Double knock requires
two activations within 10...

Page 36

Accenta/Optima Engineer’s Manual
32
LED Keypad:
Press [CHIME] to toggle double knock status on or off.
Press [9] to turn all double knock zones on.
Press [0] to turn all double knock zones off.
• Press [OMIT] to enter into menu. LED’s 1 and 2 are on.
• Press [1] to select Double Knock.
• Press zone number [1-8] to choose a particular zone.
• Press the zone [number] or [CHIME] to toggle the double
knock status on or off. The appropriate LED is on when the zone is
set up as Double Knock. Default settings...

Page 37

Accenta/Optima Engineer’s Manual
33
Omit Allow & Double Knock
LED Keypad:
Press [CHIME] to toggle omit allow status on or off.
Press [9] to turn all omit allow zones on.
Press [0] to turn all omit allow zones off.
• Press [OMIT] to enter into menu. LED 2 is on.
• Press [2] to select Omit Allow.
• Press zone number [1-8] to choose a particular zone.
• Press the [zone number] or [CHIME] to toggle the omit allow
status on or off. The appropriate LED is on when the zone is
set up as omit allow. Default...

Page 38

Accenta/Optima Engineer’s Manual
34
P = Set Up Programs
The panel uses three setting routines known as programs. Each program may have a different Exit Mode.
These are 0 = Disabled, 1 = Timed, 2 = Final Door or 3 = Silent Timed. Zones can also be assigned different
functions in different programs. Refer to the following diagram for the programming structure.
Figure 16. Programming structure
Programs
P>Set Up Programs
Select Program
1, 2 or 3
1 = Used Zones
Zones 01-08 (Yes/No)
2 = Timed Zones
Zones 01-08...

Page 39

Accenta/Optima Engineer’s Manual
35
LCD Keypad:
NOTE:Pressing the number toggles the zone ON or OFF
While in Engineer program mode, to set up zones as used,
• Press [PROG] to give a choice of programs or press
[up arrow] until P>Set Up Programs is displayed then press
[SET].
• Select program 1, 2 or 3.
• The first screen to appear is Program Edit Used Zones.
• Press [1] or [SET]. The first zone can now be set as used or
unused.
• To edit the other zones press [Number] or [up arrow] to go to
a particular...

Page 40

Accenta/Optima Engineer’s Manual
36
2 = Timed Zones
A  zone programmed as Timed would be used to protect the main entry/exit door of the entry route.
LCD Keypad:
NOTE:Pressing the number toggles the zone ON or OFF
While in Engineer program mode, to set up zones as timed,
• Press [PROG] to give a choice of programs or press
[up arrow] until P>Set Up Programs is displayed then press
[SET].
• Select program 1, 2 or 3.
• The first screen to appear is Program Edit Used Zones.
• Press [2] to enter into Timed...