Page 11

Accenta/Optima Engineer’s Manual
7
Fire Zone
Zones 7 and 8 may be programmed as fire zones. This will automatically exclude the availability of the zone
from programs and normal security applications.
 
	
   

   
  


 !#
$
 !%&()

Figure 8. Fire Zones
The fire zone detects fires all the time and will operate whether the system is Set or Unset. A fire will cause a
distinctive internal sounder tone. The external sounders...

Page 12

Accenta/Optima Engineer’s Manual
8
PA Circuit
It is recommended that no more than 10 normally closed type personal attack button may be wired in series
and then connected to the PA circuit.
Operational in Unset and Set, the PA circuit will cause a full alarm condition when activated. PA is
indicated on the control panel or RKP.
PA buttons may be fitted near the front door or in a bedroom.
Figure 9. PA Circuit




	








Extension Speaker
Extension...

Page 13

Accenta/Optima Engineer’s Manual
9
External Siren (Bell Box) Output
The external siren (bell box) is usually installed in a high position from where the siren could be seen and
heard.
Terminal TADB are for connection to the external siren. These terminals provide a power/hold-off supply,
sounder trigger and tamper circuit to protect the external siren housing.
Figure 11. External Bell-box Wiring
The terminals are summarised as follows:
T = Negative (-Ve) tamper return
A = Negative (-Ve) supply (0V)
D =...

Page 14

Accenta/Optima Engineer’s Manual
10
Figure 12. Twin External Bell-box Wiring
13V Supply Output
The 13V output is to power detectors which require a voltage supply (PIR detectors etc). The supply is
present at all times and may be used to supply a total load of 350mA.
Set
The output marked SET is used with latching detectors. The output becomes positive on correct Set of the
system and is removed by entry of a valid user code.
Bell Box (cont’d)





	


	



...

Page 15

Accenta/Optima Engineer’s Manual
11
Remote Signalling Input and Outputs
NOTE:These outputs are not applicable to the Optima compact panel.
These terminals have been provided for connection to remote signalling equipment such as a digital communi-
cator, or speech dialler.
13V 0V:  These terminals provide a 13V supply for the communicator up to a total load of 200mA.
OUTPUTS (J3): These outputs are programmed as active low output. They are held at 13V and fall to 0V
when active, it can source or sink...

Page 16

Accenta/Optima Engineer’s Manual
12
Important Notes
1. Each output has been configured as active low.
2. Where the communicator is powered from an external source, not the panel and the outputs are being
used without relays, the panel and external power supply will require a common negative supply rail.
3. If the communicator is not fitted inside the panel and abort is being used, care should be taken to ensure
that the abort connection cannot be damaged or severed as this could cause the ARC to...

Page 17

Accenta/Optima Engineer’s Manual
13
Factory Set Condition
User code1 0123
User code2Not programmed
Duress CodeNot programmed
Engineer Code9999
External siren Bell Duration 15 minutes
External siren Bell Delay No delay
Rearm Count3 Rearms
Program 1
Zone 1 Timed
Zone 2 Timed inhibit
Zone 3 - 8Immediate
Exit time 30 seconds
Entry time 30 seconds
Exit mode Timed
Program 2
Zone 1 Timed
Zone 2 Timed inhibit
Zone 3 - 8Immediate
Exit time 30 seconds
Entry time 30 seconds
Exit mode Disabled
Program 3
Zone 1...

Page 18

Accenta/Optima Engineer’s Manual
14
Mains Connection
The mains power should be connected using 3-core cable of not less than 1 mm sq. from a fused spur to the
mains connector inside the control panel. The 2 A fused spur must be located close to the control panel.
NOTE:The mains supply must be connected by a technically competent person and according to current
IEE regulations.

 
	


 




 
	
 !

#

$ %&&

  () *&
+*& 
*...

Page 19

Accenta/Optima Engineer’s Manual
15
First Power Up
NOTE:For Optima compact, fit the top cover on to the base and connect the speaker wires.
1 Check that the factory fitted links are connected to terminals PA, TAMP and T-A.
2 Fit the battery wires to the battery terminals (BATT).
3 On connecting the battery, the system will go into an alarm condition with an audible alarm indication.
After entry of a valid user code, there is a Tamper indication.
4 Fit the cover to hold down the tamper spring at the...

Page 20

Accenta/Optima Engineer’s Manual
16
Engineer Program Mode
The panel may be programmed to suit a wide variety of installations.
Once the Engineer program mode has been accessed, each configuration may be changed in any order.
Before entering Engineer program mode the system should be in the Day mode, with the Day and Power
indicators lit.
Indications on LED Keypads
ARC
Table 1. LED Indications
To exit operation
RESET
Quit the current function
Leave program menu
Return  one menu level
System Indications...