Engineer’s Manual Honeywell Security Accenta/Optima 0 123456789SetResetPAProg Omit Chime Powe r Day 8EP417A - Accenta LCD keypad 0123456789CHIMEOMITRESETPROGSET 1 23 45 67 8ZONE Accenta +TAPA D AY POWER PA 8EP416 - Accenta LED keypad 8EP396A Optima compact panel with built-in LED keypad mini Zones mini 8SP399A - Accenta mini panel with remote LCD keypad and communicator outputs. 8SP400A - Accenta mini panel with remote LED keypad and communicator outputs 8SP419A - Accenta metal panel enclosure with remote LCD keypad and communicator outputs OR 8SP420A - Accenta metal panel enclosure with remote LED keypad and communicator outputs
Accenta/Optima Engineer’s ManualTable of Contents i Contents Introduction............................................................................................................ 1 Features.................................................................................................................. 1 Installation Design................................................................................................ 2 Fixing the Control Panel ....................................................................................... 3 PCB .......................................................................................................................... 4 Wiring the System ................................................................................................. 4 Tamper Network..................................................................................................... 4 Connecting Remote Keypads............................................................................... 5 Fitting the Remote Keypad ................................................................................... 6 Security Zones ....................................................................................................... 6 Fire Zone ................................................................................................................ 7 PA Circuit ................................................................................................................ 8 Extension Speaker ................................................................................................ 8 External Siren (Bell Box) Output .......................................................................... 9 13V Supply Output............................................................................................................. 10 Set ........................................................................................................................................ 1 0 Remote Signalling Input and Outputs ............................................................... 11 Filtering of Intruder alarms ............................................................................................... 1 2 Factory Set Condition......................................................................................... 13 Mains Connection............................................................................................... 14 Testing the System .............................................................................................. 14 First Power Up ...................................................................................................... 15 Engineer Program Mode..................................................................................... 16 Indications on LED Keypads ............................................................................................ 1 6 System Indications .............................................................................................. 16 Entering/Exiting Engineer Program Mode ........................................................ 17 Defaulting Panel to Factory Settings ................................................................ 17 Defaulting User Code 1 and Engineer Code ..................................................... 17
Accenta/Optima Engineer’s ManualTable of Contents ii Menu Options ....................................................................................................... 18 0 = Walk Test ....................................................................................................................... 1 8 1 = Alarm Test ..................................................................................................................... 1 9 2 = Test Outputs................................................................................................................. 2 0 3 = Set Up System Flags .................................................................................................... 2 1 4 = Set Up Time and Date .................................................................................................. 2 4 6 = Set Up Zone Names..................................................................................................... 2 4 7 = Set Up Timers ...............................................................................................................25 8 = Set Up Codes ................................................................................................................28 C = View Event Log ............................................................................................................ 30 O = Omit Allow and Double Knock ................................................................................... 3 1 P = Set Up Programs .......................................................................................................... 3 4 Operating the System.......................................................................................... 42 Setting the System .............................................................................................................42 Resetting After an Alarm, Tamper or PA .......................................................................... 4 3 Unsetting the System ........................................................................................................ 4 3 Faults.................................................................................................................... 45 Specifications...................................................................................................... 46 Appendix 1 - Event Log Messages.................................................................... 47 Appendix 2 - Library ............................................................................................ 49 Servicing Organisation Details.......................................................................... 51 Parts ...................................................................................................................... 51
Accenta/Optima Engineer’s Manual 1 Introduction This manual provides information on Installation design, panel fixing, wiring, power up and programming of the intruder panels. Features „8 zones programmable for Security, 2 zones for Fire. „PA input. „Tamper input. „Outputs for External Siren (Bell) and Strobe. „4 Access level Codes, User 1, User 2, Engineer and Duress, all programmable. „3 fully selectable part set programs. „Chime on any security zone. „250 event memory (LCD Keypad), 8 event memory (LED keypad). „Programmable timers including bell cut off. „Walk Test facilities. „Quick set feature. „Supports up to four remote keypads with on board PA and illuminated keys positioned up to 100 meters from the panel. „Keypads can be wired in a star or daisy chain configuration from the panel. „ „„ „ „Optima is supplied with a built in keypad. „Support of Prox set and unset with Simple Set keypad. „NVM for protection of engineer program and event log. „5 digital outputs for a wire-in digital communicator or dialler (Not applicable for Optima compact panel). „Battery capacity of up to : 2.1Ah in Accenta/Optima mini enclosure, 7Ah in Accenta/Optima metal enclosure. Features 4 2
Accenta/Optima Engineer’s Manual 2 Installation Installation Design The purchase of this alarm system represents a major step forward in the protection of the property and its occupants. It is important to plan the installation before proceeding following the procedures and advice contained in this manual. Plan the position of each part of the alarm system and the cable runs. Detectors should be sited with particular regard to the degree of coverage required. All of the system wiring is connected directly to the panel. The Accenta panel may be concealed inside a cupboard or loft space, but it must be installed within the protected premises and in a position which is convenient for a mains supply. The Optima panel may be installed near an entry/exit point. The Remote Keypads (RKPs) should be mounted in positions which allows ease of operation for the system users, typically within the entry/exit route close to the final door and the master bedroom. Additional internal sound speakers are recommended, these will provide high volume alarm tones and low volume entry/exit tones. Speakers should be positioned to provide good sound distribution throughout the building and so that the exit tone is audible outside the main entry / exit door. This will enable the system operator to check that the system is setting correctly. The total current output of this control system (in alarm condition) is 1A when supported by a fully charged battery. Calculate the total including the panel, remote keypads, external siren with strobe light (also called a bell box) and detectors to ensure that this rating is not exceeded. Depending on which area you live, you may be required, by law to notify the Local Authority and Police of the new security alarm installation. The local authority requirements may differ from area to area, therefore, it is advisable to contact local environmental officer to obtain full details of your area requirements. 0 123456789SetResetPAProg Omit Chime Power D ay Accenta LCD keypad
Accenta/Optima Engineer’s Manual 3 Fixing the Control Panel CAUTION:When positioning the control panel make sure that it is located in a dry place away from damp areas. NOTE:The Accenta mini enclosure is illustrated here, however the procedures for the other panels is similar. Control Panel 2. Disconnect the transformer wires from the board, these are marked AC. Carefully remove the board by gently pushing downthe holding clips on the bottom edge of the board and withdraw it from the base. NOTE: When replacing the board align it on the round support pillars to the bottom and allow it to click down past the clips at the top of the case. Refit the transformer wires into the terminal. 1. Remove the front cover(s) from the base assembly. 3. Fit the panel to the wall with suitable fixings. Ensure the wall surface is flat to prevent base distortion. There are cable entry holes provided in the rear of the base and around the outside edges through the thinned out plastic sections which may be cut away as required. NOTE:The hole provided adjacent to the mains transformer is a dedicated mains cable entry hole. ! #$%&( Figure 1. Removing the Front Cover Figure 2. Removing the PCB Figure 3. Fitting the Panel
Accenta/Optima Engineer’s Manual 4 PCB There are four fuses mounted on the circuit board, all are 20mm anti-surge. F1 1.6A - to protect the positive (+Ve) line of 12V battery F2 1A - to protect the Speaker 13V supply F3 1A - to protect the Siren (Bell) & Strobe supply F4 1A - to protect the RKP 13V supply As supplied, wire links are fitted across the PA and Tamper terminals to represent a closed circuit. Wiring the System CAUTION:Always power down the panel when wiring external circuits to prevent damage to the panel electronics. Systematically wire and test each circuit: „Zone, Tamper circuit and PA circuits „Finish by wiring any additional extension speaker sounders, external siren (bell) / strobe and the 13V supply. Tamper Network The Tamper circuit is used to protect all cables and detectors in the system from unauthorised access including the panel and RKP covers. The zone and PA tampers should be series wired and connected to the TAMP terminals. Terminals T and A are for the external siren tamper. The TAMP terminals at the bottom left of the board are for the RKP tampers. Tamper alarms that occur in the Day mode operate internal sounders only. Tamper alarms in Set cause a full alarm condition. Tamper is indicated on the control panel and RKPs.Figure 4. PCB PCB ! ##$%&()* &+ %) ,&))-. ) /)( #/() /(%-0-1/(. (%. + 2-3-/) 4-* 5 (*- %) ,&))-. ) -%)( #-)(0 /(%-0+ (%. -%)( #&%& /(%-0+ !
Accenta/Optima Engineer’s Manual 5 Figure 5. Connecting LED keypads to panel Connecting Keypads Connecting Remote Keypads NOTE:Where an Accenta or Accenta mini panel is being installed, make sure there is at least one remote keypad wired to the panel before the first power up. Up to four remote Accenta LCD or LED keypads can be connected to the panel. Wire the keypad(s) as per Figure 5 (LED keypad) or Figure 6 (LCD keypad). NOTE:When the panel back-up battery is charging, the LCD keypad backlight may not operate.Figure 6. Connecting LCD keypads to panel !#$# % $ & & #& () * +13V0V soundTB1comms tamp tampTB2 Keypad PCB +13V0V soundTB1comms tamp tampTB2 Keypad PCB Board Panel
Accenta/Optima Engineer’s Manual 6 Security Zones It is recommended that no more than 10 magnetic contacts are connected to the same zone and that the combined cable length for each zone does not exceed 100 metres. Figure 7. Security Zone Wiring Fitting the Remote Keypad 1 Separate the RKP baseplate from the main assembly by slackening the retaining screw. 2 Cut away the required thin wall sections around the edges of the baseplate for cable entry. 3 The baseplate mounting holes are 60 mm centres (LED keypad) or 75 mm (LCD keypad) which allow it to be fixed to a single gang electrical metal box. As an alternative, the baseplate may be fitted directly to the wall using screws and wall plugs. If these are not appropriate for the wall then use suitable alternative fixings. CAUTION:The PCB board must not be removed from the front moulding and doing so may invalidate the warranty. 4 Bring the cables into the baseplate and wire to the terminal block on the baseplate. 5 Refit the RKP main assembly to the baseplate by locating the top retaining clips into the inside top part of the baseplate. Close the main assembly onto the baseplate, ensuring that the wiring does not foul the tamper switch/spring or the PCB support pillars. Resecure the screw in the bottom of the case. Remote Keypad !