Home > Honeywell > Scanner > Honeywell 1900ghd-2 User Manual

Honeywell 1900ghd-2 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Honeywell 1900ghd-2 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							9 - 13
    nK Apply gamma correction factor n (n = 1-255)
    R - Resolution of Signature Capture Area
    The resolution is the number of pixels that the scanner outputs per each minimum bar width.  The higher the value for R, 
    the higher the quality of the image, but also the larger the file size.  Values begin at 1000.  The scanner automatically 
    inserts a decimal point between the first and second digit.  For example, use 2500 to specify a resolution of 2.5.  Set to zero 
    when using the A and B modifiers (see A - Output Image Width and B - Output Image Heighton page 9-12).
    S - Bar Code Aspect Ratio
    All dimensions used in IMGBOX are measured as multiples of the minimum element size of the bar code.  The bar code 
    aspect ratio allows you to set the ratio of the bar code height to the narrow element width.  In the example, the narrow ele-
    ment width is .010 inches and the bar code height is 0.400 inches, resulting in a value of S = 0.4/0.01 = 40.
    W - Width of Signature Capture Area
    The width of the signature capture area must be measured in inches divided by .01.  In the example, the width of the area 
    to be captured is 2.4 inches, resulting in a value of W = 2.4/0.01 = 240.  (A value of 245 was used in the example to accom-
    modate a slightly wider image area.)
    Example of Gamma Correction 
    set to 50K: Example of Gamma 
    Correction set to 0K:
    Example of Gamma Correction 
    set to 255K:
    Example of Resolution set to 1000R: Example of Resolution set to 0R:
    Example of Resolution set to 2000R:
    Example:   IMGBOX245w37h55y. 
    						
    							9 - 14
    X - Horizontal Bar Code Offset
    The horizontal bar code offset allows you to offset the horizontal center of the signature capture area.  Positive values move 
    the horizontal center to the right and negative values to the left.  Measurements are in multiples of the minimum bar width.  
    Y - Vertical Bar Code Offset
    The vertical bar code offset allows you to offset the vertical center of the signature capture area.  Negative numbers indi-
    cate that the signature capture is above the bar code, and positive numbers indicate that the area is below the bar code.  
    Measurements are in multiples of the minimum bar width.   
    RF Default Imaging Device
    The scanner supports imaging command processing (IMGSHP, IMGSNP, IMGBOX) so that EZConfig-Scanning (see page 11-3) 
    and other applications are able to perform imaging functions as if they were communicating directly with a scanner.  To accom-
    plish this, the scanner uses a menu command called RF_DID (RF Default Imaging Device).  RF_DID is the name of the scanner 
    (BT_NAM) that is to receive imaging commands.  The default for RF_DID is “*”indicating that imaging commands are to be sent 
    to all associated scanners.  Change this setting to RF_DIDscanner_name to ensure that they are sent to a particular scanner.  
    Refer to Pagingon page 3-7 to generate a report containing the port, work group, scanner name, and address for each scan-
    ner.  Refer to Scanner Nameon page 3-18 set a unique name for each scanner.
    Example of Horizontal Offset set to -75X:Example of Horizontal Offset set to 75X:
    Example of Vertical Offset set to -7Y:
    Example of Vertical Offset set to 65Y: 
    						
    							10 - 1
    10
    Interface Keys
    Keyboard Function Relationships
    The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+  relationships apply to all terminals that can 
    be used with the scanner.  Refer to page 2-17 enable Control + X (Control + ASCII) Mode.
    The last five characters in the Full ASCII “CTRL”+ column  ( [  ] 6 - ), apply to US only.  The following chart indicates the equiva-
    lents of these five characters for different countries. Function Code HEX/ASCII Value Full ASCII (CTRL + X Mode)
    NUL 00 @
    SOH 01 A
    STX 02 B
    ETX 03 C
    EOT 04 D
    ENQ 05 E
    ACK 06 F
    BEL 07 G
    BS 08 H
    HT 09 I
    LF 0A J
    VT 0B K
    FF 0C L
    CR 0D M
    SO 0E N
    SI 0F O
    DLE 10 P
    DC1 11 Q
    DC2 12 R
    DC3 13 S
    DC4 14 T
    NAK 15 U
    SYN 16 V
    ETB 17 W
    CAN 18 X
    EM 19 Y
    SUB 1A Z
    ESC 1B [
    FS 1C \
    GS 1D ]
    RS 1E ^
    US 1F _
    Country
    Codes
    United States[\]6-
    Belgium [ < ] 6 -
    Scandinavia8
    						
    							10 - 2
    Denmark8\96-
    Norway 8 \ 9 6 -
    Spain[\]6- Country
    Codes 
    						
    							10 - 3
    Supported Interface Keys
    ASCIIHEX
    IBM PC/AT and  
    Compatibles, 
    USB PC 
    Keyboard
    Apple Mac/iMac 
    Supported Keys
    NUL 00 Reserved Reserved
    SOH 01 Enter (KP) Enter/Numpad Enter
    STX 02 Cap Lock CAPS
    ETX 03 ALT make ALT make
    EOT 04 ALT break ALT break
    ENQ 05 CTRL make CNTRL make
    ACK 06 CTRL break CNTRL break
    BEL 07 CR/Enter RETURN
    BS 08 Reserved APPLE make
    HT 09 Tab TAB
    LF 0A Reserved APPLE break
    VT 0B Tab TAB
    FF 0C Delete Del
    CR 0D CR/Enter RETURN
    SO 0E Insert Ins Help
    SI 0F Escape ESC
    DLE 10 F11 F11
    DC1 11 Home Home
    DC2 12 Print Prnt Scrn
    DC3 13 Back Space BACKSPACE
    DC4 14 Back Tab LSHIFT TAB
    NAK 15 F12 F12
    SYN 16 F1 F1
    ETB 17 F2 F2
    CAN 18 F3 F3
    EM 19 F4 F4
    SUB 1A F5 F5
    ESC 1B F6 F6
    FS 1C F7 F7
    GS 1D F8 F8
    RS 1E F9 F9
    US 1F F10 F10
    DEL 7F BACKSPACE 
    						
    							11 - 1
    11
    Utilities
    To Add a Test Code I.D. Prefix to All Symbologies
    This selection allows you to turn on transmission of a Code I.D. before the decoded symbology.  (See the Symbology Charts, 
    beginning on page A-1) for the single character code that identifies each symbology.)  This action first clears all current prefixes, 
    then programs a Code I.D. prefix for all symbologies.  This is a temporary setting that will be removed when the unit is power 
    cycled.
    Show Decoder Revision
    Scan the bar code below to output the decoder revision.
    Show Scan Driver Revision
    Scan the bar code below to output the scan driver revision.  The scan driver controls image capture.
    Show Software Revision
    Scan the bar code below to output the current software revision, unit serial number, and other product information for both the 
    scanner and base.
    Show Data Format
    Scan the bar code below to show current data format settings.
    Add Code I.D. Prefix to
    All Symbologies (Temporary)
    Show Decoder Revision
    Show Scan Driver Revision
    Show Software Revision
    Data Format Settings
    DFMBK3?. 
    						
    							11 - 2
    Test Menu
    When you scan the Test Menu On code, then scan a programming code in this manual, the scanner displays the content of a 
    programming code.  The programming function will still occur, but in addition, the content of that programming code is output to 
    the terminal.  
    Note: This feature should not be used during normal scanner operation.
    TotalFreedom
    TotalFreedom is an open system architecture that makes it possible for you create applications that reside on your scanner.  
    Decoding apps and Data Formatting  apps can be created using TotalFreedom.  For further information about TotalFreedom, go 
    to our website at
     www.honeywellaidc.com.
    Application Plug-Ins (Apps)
    Any apps that you are using can be turned off or on by scanning the following bar codes.  Apps are stored in groups: Decoding, 
    and Formatting.  You can enable and disable these groups of apps by scanning that group’s On or Off bar code below.  You can 
    also scan the List Apps bar code to output a list of all your apps. 
    Note: You must reset your device in order for the apps setting to take effect.
    On
    * Off
    * Decoding Apps On
    Decoding Apps Off
    * Formatting Apps On
    Formatting Apps Off
    List Apps 
    						
    							11 - 3
    EZConfig-Scanning Introduction
    EZConfig-Scanning provides a wide range of PC-based programming functions that can be performed on a scanner connected 
    to your PC.  EZConfig-Scanning allows you to download upgrades to the scanners firmware, change programmed parameters, 
    and create and print programming bar codes.  Using EZConfig-Scanning, you can even save/open the programming parameters 
    for a scanner.  This saved file can be e-mailed or, if required, you can create a single bar code that contains all the customized 
    programming parameters and mail or fax that bar code to any location.  Users in other locations can scan the bar code to load in 
    the customized programming. 
    EZConfig-Scanning Operations
    The EZConfig-Scanning software performs the following operations:
    Scan Data
    Scan Data allows you to scan bar codes and display the bar code data in a window.  Scan Data lets you send serial 
    commands to the scanner and receive scanner response that can be seen in the Scan Data window.  The data dis-
    played in the Scan Data window can either be saved in a file or printed. 
    Configure
    Configure displays the programming and configuration data of the scanner.  The scanners programming and configu-
    ration data is grouped into different categories.  Each category is displayed as a tree item under the Configure tree 
    node in the application explorer.  When one of these tree nodes is clicked, the right-hand side is loaded with the 
    parameters form belonging to that particular category.  The Configure tree option has all the programming and con-
    figuration parameters specified for a scanner.  You can set or modify these parameters as required.  You can later write 
    the modified settings to the scanner, or save them to a dcf file. 
    Imaging
    Imaging provides all the image-related functions that a 2D Scanner can perform. You can capture an image using the 
    current settings, and the image will be displayed in an image window.  Images captured from the scanner can be saved 
    to files in different image formats.  You can modify the image settings and save the image settings to an INI file, which 
    can be loaded later to capture new images.  Imaging also lets you preview the images continuously captured by the 
    scanner. 
    Installing EZConfig-Scanning from the Web
    Note: EZConfig-Scanning requires .NET software.  If .NET is not installed on your PC, you will be prompted to install it 
    during the EZConfig-Scanning installation.
    1. Access the Honeywell web site at
     www.honeywellaidc.com
    2. Click on the Resources tab.  Select Software.
    3. Click on the dropdown for Select Product Number.  Click on your product number.
    4. Click on the listing for EZConfig-Scanning.
    5. When prompted, select Save File, and save the files to the c:\windows	emp directory.  
    6. Once you have finished downloading the file, exit the web site.
    7. Using Explorer, go to the c:\windows\temp file.
    8. Double click on the Setup.exe file.  Follow the screen prompts to install the EZConfig-Scanning program.
    9. If you’ve selected the defaults during installation, you can click on Start Menu-All Programs-Honeywell-EZConfig-
    Scanning. 
    						
    							11 - 4
    Resetting the Factory Defaults
    If you aren’t sure what programming options are in your scanner, or you’ve changed some options and want to restore the scan-
    ner to factory default settings, first scan the Remove Custom Defaults bar code, then scan Activate Defaults.  This resets the 
    scanner to the factory default settings.
    Note: If using a cordless system, scanning the Activate Defaults bar code also causes both the scanner and the base or Access 
    Point to perform a reset and become unlinked.  The scanner must be placed in its base to re-establish the link before any 
    setup codes are entered.  If using an Access Point, the linking bar code must be scanned.  See Cordless System 
    Operationbeginning on page 3-1 for additional information.
    The Menu Commands, beginning on page 12-4 list the factory default settings for each of the commands (indicated by an aster-
    isk (*) on the programming pages).This selection erases all your settings and resets the scanner to the original factory defaults.  It also disables all plugins.
    !
    Remove Custom Defaults
    Activate Defaults 
    						
    All Honeywell manuals Comments (0)

    Related Manuals for Honeywell 1900ghd-2 User Manual