Hitachi F 2500 Manual
Here you can view all the pages of manual Hitachi F 2500 Manual. The Hitachi manuals for Spectrophotometer are available online for free. You can easily download all the documents as PDF.
Page 51
1 - 32 (1) Display Tab Items to be displayed when opening a saved data file or data immediately after measurement can be set here. Set the number of data columns to be displayed. The items other than the number of display columns to be set here can also be set by a tool button or View menu after measurement. Fig. 1-31 Display Tab (a) Trace Put a check mark in this box, and spectrum can be traced when the data processing window is open. (b) Ruled line The contents...
Page 52
1 - 33 (d) Time scan Items to be displayed when opening the data processing window in the time scan mode can be set. 1) Show graph only 2) Show graph plus kinetics data 3) Show graph plus peak table (e) 3-dimensional (effective for Model F-2500 when the ‘3-D Scan program’ (option) is installed) Items to be displayed when opening the data processing window in the time scan mode can be set. 1) Show contour plus EXEM spectrum 2) Show contour, EXEM spectrum plus peak table...
Page 53
1 - 34 (i) Fluorescence polarization spectrum (effective when the ‘fluorescence polarization measurement program’ (option) is installed) Items to be displayed when opening the data processing window in the fluorescence polarization mode can be set. 1) Show fluorescence only 2) Show fluorescence plus polarization 3) Show fluorescence plus anisotropy 4) Show fluorescence, polarization plus anisotropy (2) Fonts Tab Display font, character size, etc. can be set. Printer...
Page 54
1 - 35 (b) Printer Font Printer font is settable. Clicking Select (S) presents the following dialog box. Fig. 1-33 Font Specification Set Font, Font style and Size. (3) Processing Tab Fig. 1-34 Processing Tab 1.8
Page 55
1 - 36 (a) Area integration method 1) Rectangular 2) Trapezoid 3) Romberg (b) Calibration A calibration curve formula to be used for the Photometry mode can be set. 1) Data = f(Conc) 2) Conc = f(Data) (c) Peak table Inclusion of area calculation item in the peak table can be selected or avoided. (d) Smooth The initial values of data processing function parameters can be set. However, this setting will not be reflected on the parameters of Analysis Method window....
Page 56
1 - 37 Click Select. The dialog box shown in Fig. 1-36 is then presented. A basic color or custom color is selectable. If there is no basic color you want, click Define Custom Colors (D). Fig. 1-36 Color Setting The dialog box shown in Fig. 1-37 will appear. Select hue, saturation, luminance, etc. and click Add to Custom Colors (A). Your color is then added to the custom colors. So select it and click OK. Fig. 1-37 Addition of Color 1.8
Page 57
1 - 38 (4) Startup Tab Analysis method to be taken upon startup of the FL Solutions program is settable here. Fig. 1-38 Startup (a) Restore last method used The method used last will be brought in. (b) Auto Parameter File The instrument will start with the fixed method brought in. Click the model name of your instrument. Fig. 1-39 Specify a file and click Open (O). 1.8 Window Setting
Page 58
1 - 39 1.9 Saving a Data File Data can or cannot be saved depending on setting. So perform setting with reference to the following table. Setting is any of patterns ① to ⑤ is recommended. Setting “Use sample table” ON/OFF Sample Name/Comment Input (“Use sample table” OFF) Automatic saving ON OFF Analysis Method - Monitor tab “Open data processing window after data acquisition” ON OFF ON OFF ON OFF Display ○ ☓ ○ ☓ ○ ☓ Automatic saving ○ ○ ○ ○ Result Manual saving...
Page 59
1 - 40 1.10 Entry of File Name for Saving File name needs to be set before measurement. Select the Sample Table (S) command in the Edit menu (E), and the dialog box shown in Fig. 1-40 will open. Input a sample name and comment. Then, bring the cursor to the file name column and click the button at (1). Fig. 1-40 The dialog box shown in Fig. 1-41 will appear. Enter your choice for “Save In” and specify “File Name.” Fig. 1-41 (1) 1.10 Entry of File...
Page 60
1 - 41 After input, click Save. If the file name field remains blank, a file name such as default001.uds is automatically given. Once a measurement has been performed, you may perform the next ones with no change in setting (using the same sample table). In this case, file names “Sample 001.uds”, “Sample 002.uds” and so on will be given. However, when there is no file name in a loaded analysis method file, file names will be given using the analysis method name as follows; Method .uds,...