Page 521

TL-130400-1001Table 21.1CPG Error Messages (Continued)
DESCRIPTION OF MESSAGESTHE CARD TO THE LEFT OF THIS SLOT IS AN
OVERSIZED CARD.
THE RIGHT HALF OF THAT CARD FILLS THIS SLOT.
REQUIRED VALUES FOR THE
ECORD DEPENDING ON THE
TRUNK APPLICATION ON THE 
Tl RECORD:
(Tl RECORD)
DIC
TC-66ILLEGAL VALUE
FOR DIC, PAG,
OR REC APPL
TC-66ILLEGAL VALUEPHYSICAL TRUNK TYPE
FOR TRUNKTHERE ARE CERTAIN REQUIRED VALUES FOR THE
APPLICATIONPHYSICAL TRUNK TYPE FIELD ON A TC RECORD
DEPENDING ON THE TRUNK APPLICATION...

Page 522

TL-130400-1001ZPG ERROR
MESSAGES
Table 21.1CPG Error Messages (Continued)TITLE
DESCRIPTION OF MESSAGES
TC-67
ILLEGAL VALUE
FOR DIC, PAG
OR REC APPL
ILiEGAL VALUESUPERVISORY INCOMING SIGNAL - SUPERVISORY
FOR TRUNKOUTGOING SIGNAL
APPLICATIONTHERE ARE CERTAIN REQUIRED VALUES FOR THE
SUPERVISORY INCOMING SIGNAL AND THE
SUPERVISORY OUTGOING SIGNAL DEPENDING ON
THE TRUNK APPLICATION INDICATED ON THE 
TlRECORD (DEPENDING ON SVR).
TC-68TRUNKSUPERVISORYSUPERVISORY
APPLICATION INCOMINGOUTGOING
(Tl RECORD)...

Page 523

TL-130400-1001Table 21.1CPG Error Messages (Continued)DESCRIPTIONOF MESSAGES
EQUIRED VALUES FOR THE
ON A TC RECORD DEPENDING
ON THE TRUNK APPLICATION INDICATED ON THE 
TlRECORD (DEPENDING ON SVR):
APPLICATIONGUARANTEED
ACCESS
SPECIFIED MUST BE
DASHES FOR
‘, ‘DIG’, ‘PAG’, ‘REC’
SIGNAL FORRECORD IS ‘FA’ (FAST ACCESS TRUNK),
FAST ACCESSTHEN THE TRUNK INCOMING SIGNAL FOR ITS TRUNK
GROUP ON THE 
Tl RECORD MUST BE ALL DASHED
A TRUNK APPLICATION
ID SOURCE GROUP
Y OUTGOING
SIGNAL OF ‘ID’, OR ‘SO’ MUST HAVE DIAL...

Page 524

TL-130400-1001Table 21.1CPG Error Messages (Continued)DESCRIPTION OF MESSAGES
PNA MUST HAVE A CLASS OF
ES STATION ACCESS ON
D TCFOR THE SAMELINEDIRECTORY
HAVING A DISPLAYABLE CLASS OF SERVICE WITH
’ (CO LINE) SHOULD BE SPECIFIED ON TC AS A CO
E DIRECTORY NUMBER.
BUT THE TRUNK
D 
Tl WAS NOT ‘COT’
BE 
CONTINOUSMUST BE NUMBERED IN SEQUENTIAL ORDER
BEGINNING WITH MEMBER ZERO WITH NO GAPS OR
DUPLICATES ALLOWED.
TC-87IF ONE TRK HAS SUPERVISORY OUTGOING SIGNAL ‘SO’ MUST BE
SUPYUSED FOR ALL MEMBERS OF A TRUNK...

Page 525

TL-130400-1001Table 21.1CPG Error Messages (Continued)2ND FEATURETRANSLATION TYPE
GIVEN THE TRANSLATION TYPE, THE SELECT GROUP
AND THE NUMBER OF DIGITS OUTPULSED MUST BE
ENTERED AS THE FOLLOWING:
TRANSLATIONSELECT NO. OF
TRUNKDIGITS
GROUPOUTPULSED
LOC --
MRS --
00-63 
-MRN --
FOR ALL TRANSLATION TYPES EXCEPT ‘MRN’,
THE MERS ON-NET NPA-CODE FIELD MUST BE
THE ON-NET NPA-CODEFIELD MUST BE SPECIFIED
THE 
Tl RECORD FOR
HAVE VALUES OF ‘DIC’,
GROUP MUST BE DEFINED ON A
SVR 5210
8187D-529 

Page 526

TL-130400-1001Table 21 .lCPG Error Messages (Continued)CPG ERROR
MESSAGES
D-530TD-56
. . .TD-57
TD-60
TD-61
TF-01
TL-01
TL-01
TL-01TITLE
HUNDREDS
GROUP
CONFLICT
HUNDREDS .
GROUP NOT
FOUND
POSSIBLE
CONFLICT WITH
MERS 3-DIGIT
TRANSLATION
ONLY 4 UNIQUE
NPAS ALLOWED
DASHES MUST
BE USED
CONSISTENTLY
IN FIELD
ELEMENTS
HAVE
INCOMPATIBLE
VALUES
ELEMENT 2 IS
MEANINGLESS
SPECIFICATION
2ND FEATURE
REQUIRED IF
FIRST
SPECIFIEDDESCRIPTION OF MESSAGES
IF THE FIRST TWO DIGITS HAVE THE FORM ‘OX’, THEN
BOTH
‘OX’ AND ‘X’...

Page 527

TL-130400-1001Table 21.1CPG Error Messages (Continued)CPG ERROR
MESSAGESTITLEDESCRIPTION OF MESSAGES
TL-51
. . . .PRINTER
THE PRINTER ID IDENTIFIES A SPECIFIC PRINTER
NUMBER NOTNUMBER OR SEVERAL PRINTER NUMBERS
FOUNDDEPENDING ON THE VALUE RANGE ENTERED.
>-ALL PRINTER NUMBERS INDICATED BY THE PRINTER
ID MUST BE VALID PRINTER NUMBERS ON A PD
RECORD.
. .PRINTERPRINTERIDNUMBER(S)
0NONE
10
21
30,1
42
502
612
70912
8
3
9093
10I,3
11
0,1,3
1223
13023
141,2,3
150,1,2,3TL-52
OPI CARD NOTPMS FIELDS ON TL REQUIRE...

Page 528

TL-130400-1001Table 21.1CPG Error Messages (Contjnued)
DESCRIPTION OF MESSAGESTHEPEC, GROUP, SLOT, AND CIRCUIT FUNCTION
ALLOWED FORSPECIFIED MUST BE VALID FOR THE CARD TYPE
DEFINED ON FR (FOR THIS PEC TYPE).
TONE DETECTOR CIRCUIT MUST APPEAR ON A TDET 1
THAT INDICATES THAT A CARD IN THE PREVIOUS
LOCATION IS A WIDE CARD AND IT OVERHANGS INTO
THIS PHYSICAL LOCATION ON FR.
THE PECGROUP, SLOT, AND CIRCUIT SPECIFIED
VALID FOR THIS PEC TYPE.
PHYSICAL LOCATION
P, SLOT, AND CIRCUIT SPECIFIED FOR
CTOR CIRCUIT...

Page 529

TL-130400-1001
CPG ERROR
MESSAGES
TR-02>-
. . . .
TR-51TR-52
I  
~TR-53
1  TR-54
TR-55
TR-56
1  TR-57
TR-58
TR-59
Table 21.1TITLE
DASHES MUST
BE USED
CONSISTENTLY
IN FIELD
MERS NPA NOT
ON MR, NT, OR
TD FORM
SENDING INST.
NOT DEFINED
ROUTING LIST
NOT DEFINED
MERS NPA NOT
PREVIOUSLY
DEFINED
DUPLICATE ABC
ENTRY
TIME PERIOD
DATA
REQUIRED
TIME PERIOD
NOT FOUND
TIME PERIOD
VALUES MUST
MATCH ACROSS
ALL RECORDS
ROUTE
LIST/SEND
INSTR DO NOT
HAVE SAME NO.
OF SELECT
ORDERS
CPG Error Messages (Continued)DESCRIPTION...

Page 530

TL-130400-1001
Table 21.1CPG Error Messages (Continued)CPG ERROR
MESSAGES
TR-60
TT-03
TT-04
TT-05
TT-06
TT-51TV-60
TT-61
D-534
TITLEABC CODE
CONFLICTS
WITH NPA,BUT
CONFLICT
CODE IS NOT Y
ON MR
# OR * BEING
OUTPULSED 
‘ONNON-DTMF
TRUNK GROUP
SECOND
ELEMENT
CONTAINS
INVALID VALUE
SECOND
ELEMENT
CONTAINS
INVALID VALUE
ELEMENT 2 IS
MEANINGLESS
SPEClFlCATlONELEMENTS
HAVE
INCOMPATIBLE
VALUES
SECOND
ELEMENT
CONTAINS
INVALID VALUE
DUPLICATE TTY
NUMBER
ESP NOT
EQUIPPED ON
OEFADS AUTO
DUMP CAN BE
‘Y’ FOR ONLY
ONE...