Page 501

TL-130400-1001Table 21.1CPG Error Messages (Continued)CPG ERROR
MESSAGESTITLE
DESCRIPTION OF MESSAGES
OD-01
. . .OD-50
OD-51VALUE OFTYPE 
- IDENTIFIER
SECOND
FOR EACH TYPE, THE IDENTIFIER MUST BE IN THE
ELEMENT TOOAPPROPRIATE RANGE AS THE FOLLOWING CHART
SMALLINDICATES.
(INVALIDNUMBER OFTYPEIDENTIFIER RANGE
DIGITS TO
_---------------OUTPULSE) 
,_RMA0000VMS0000-0063 TRUNK GROUP
SPD0001-0008 SPEED CALL LIST
ENTRY
MDU0000-0063 TRUNK GROUP
TGS0000-0063 TRUNK GROUP
TGOXXW WHERE XX = 00-15
NUMBER OF DIGITS...

Page 502

TL-130400-1001Table 21.1CPG Error Messages (Continued)CPG ERROR
MESSAGESTITLE
DESCRIPTION OF MESSAGES
OE-51IF ESP IS
EQUIPPED ON
OE, PORT 1 ON
MTyMUST BE
. . .PRESENT
OE-5-l 
_REQUIREDIF THE ESP IS EQUIPPED ON THE OE RECORD, THEN
DATA NOT
AN MT RECORD WITH PORT 1 MUST BE PRESENT.
FOUND .
(ENDCHK)
OE-52IF ESP IS
EQUIPPED ON
OE, TRANS.
RATE ON MT
MUST BE 2400
OE-52
OE-53FIELD DOESN’TIF THE ESP IS EQUIPPED ON THE OE RECORD, THEN
HAVETHE TRANSMISSION RATE FOR PORT 1 ON THE MT
REQUIREDRECORD MUST BE 2400...

Page 503

TL-130400-1001Table 21.1CPG Error Messages (Continued)
DESCRIPTION OF MESSAGESIF THE TRAVELING CLASS MARK FIELD IS DASHED,
INVALID VALUETHEN THE DEFAULT FRL ON MERS QUEUE TIMEOUT
VALUES MUST BE DASHED.
0 THE MINIMUM
TIMING VALUE.
WHEN THENCC OUTPUT SCAN TIME INTERVAL IS
SPECIFIED ON
THEN THE NCC PORT USAGE SHOULD BE SPECIFIED
ON THE OE RECORD.
OUTPUT SCAN
NOT SPECIFIEDTHEN THE NCC OUTPUT SCAN TIME INTERVAL
SHOULD BE SPECIFIED ON THE OV RECORD.
PC-01VALUES TO BEPREFIX DIGITS
FILLED LEFT TOIF THERE ARE...

Page 504

TL-130400-I 001
CPG ERRORTable 21.1 CPG Error Messages (Continued)
DESCRIPTION OF MESSAGES
REQUIRED IFIF AT LEAST ONE PREFIX DIGIT IS AN ‘A’, ‘D’, OR ‘E’,
THEN RESTRICTION INDICATOR CANNOT BE DASHED.iJ CIRCUIT HAS BEEN PLACED IN THE
SAME CARD SLOT, THEN ONLY ONE PRINTER CIRCUIT
ADDRESSESMAY BE PLACED IN THAT CARD SLOT.
(TABGENiGENMIS)MUST HAVE A BAUDRATE OF
1200,NO
PARITY, AND 2
DEFINED ON FR
INCOMPATIBLE
8187SVR 5210 

Page 505

CPG ERROR
MESSAGESPD-52
. . .PD-52
PD-52
PD-52
PD-52PD-52
PD-53PD-54
SVR 5210
Table 21.1TITLE
FUNCTION OF
CARD NOT
ALLOWED FOR
CARD TYPE
DEFINED ON
FORM FR
NONEXISTENT
PHYSICAL
LOCATION
PHYSICAL
LOCATION NOT
DEFINED ON
RECORDCODE
FRPHYSICAL
LOCATION
PREVIOUSLY
FILLED
CARD
OVERHANGS
INTO A
PREVIOUSLY
FILLED SLOT
PREVIOUS
CARD
OVERHANGS
INTO THIS SLOT
DUPLICATE
PRINTER
NUMBER
PEC NUMBER IS
NOT EQUIPPEDTL-130400-1001
CPG Error Messages (Continued)DESCRIPTION OF MESSAGES
PHYSICAL LOCATION
THE PEC, GROUP,...

Page 506

TL-130400-1001Table 21.1CPG Error Messages (Continued)CPG ERROR
MESSAGES I
PN-53
. . .PN-54
PN-55
PZ-52
Pl-51
P2-51
RA-01
RA-01
D-51 0TITLE
PNA PILOT
NUMBER NOT
PREVIOUSLY
ENTERED
DUPLICATE PNA
DESTINATION
NUMBER
AN MDU DIR.
NO. ON OD
MUST APPEAR
ON RECORD
CODE PN
FIELD
CONFLICTS
WITH LISTED
FIELD
IF ADMP PORT
TIMEOUT IS
SPECIFIED, AN
ADMP PORT
MUST BE
DEFINED ON CP
DUPLICATE
ADMP DUMP
TYPE
ELEMENTS
HAVE
INCOMPATIBLE
VALUES
ELEMENT 2 IS
MEANINGLESS
SPECIFICATIONDESCRIPTION OF MESSAGES
THE PNA PILOT...

Page 507

TL-130400-1001Table 21.1
CPG Error Messages (Continued)DESCRIPTION OF MESSAGES
2ND FEATURE
REQUIRED IFANNOUNCER (RA 
#1 - RA #3) OR ALTERNATE
RECORDER ANNOUNCER (ALT RA 
#l - ALT RA #3),.--THE TRUNK NUMBER SHOULD ALSO BE SPECIFIED. IF
RECORD MUST APPEAR ON A TC RECORD WITH AN
APPLICATION OF ‘REC’ ON A 
Tl RECORD.
LISTED FORM
ANNOUNCER
NONEXISTENTTHE CARD SLOT WAS ASSIGNED TO A NONEXISTENT
PHYSICALPHYSICAL LOCATION.
LOCATION
RC-52CARD
OVERHANGS
INTO A
PREVIOUSLY
FILLED SLOTTHIS CARD IS AN OVERSIZED CARD...

Page 508

TL-130400-1001
CPG ERROR
MESSAGESTable 21.1CPG Error Messages (Continued)TITLE
DESCRIPTION OF MESSAGES
RC-54
. . . .CARD TYPEPHYSICAL LOCATION
DEFINED ON FRTHE PEC, GROUP, SLOT, AND CIRCUIT FUNCTION
INCOMPATIBLESPECIFIED MUST BE VALID FOR THE CARD TYPEWITN INCOMINGDEFINED ON FR (FOR THIS PEC TYPE).
CARD TYPEAN RLT CIRCUIT MUST APPEAR ON AN RLT OR ERLT
CARD.
(PHYLOC)
RC-54
FUNCTION OF’
PHYSICAL LOCATION
CARD NOTTHE PEC, GROUP, SLOT, AND CIRCUIT SPECIFIED
ALLOWED FOR
MUST BE VALID FOR THE CARD TYPE DEFINED...

Page 509

ITL-130400-1001
SPG ERROR
MESSAGES
Table 21.1CPG Error Messages (Continued)TITLEDESCRIPTION OF MESSAGES
RN-01
. . . .
RN-51VALUE OFCODE TYPE 
- CODE TYPE IDENTIFIER
SECONDFOR EACH VALUE OF CODE TYPE, REQUIRED VALUES
ELEMENT TOOOR VALUE RANGES ARE INDICATED AS FOLLOWS:
LARGE
CODECODE TYPE
TYPEIDENTIFIER
--------------
. .INTo-1 5
3DGo-9, 12
4DG15DUPLICATETHE ROOM NUMBER 
1ST DIGIT MUST BE UNIQUE
LINE(ROOM)ACROSS ALL RN RECORDS.
NUMBER 
1STDIGIT
RN-52
RP-01INTERCEPTIF THE CODE TYPE IS ‘INT’,
ROUTING...

Page 510

TL-130400-1001Table 21.1CPG ERROR
MESSAGES
RP-03
R6-03
RP-51
RP-52
RP-53
RP-53
RP-55
RP-60
RP-61
1
D-51 4TITLE
ELEMENT 2 IS
MEANINGLESS
SPECIFICATION
ELEMENTS
HAVE
INCOMPATIBLE
VALUES
ROUTING LIST
NOT USED
DUPLICATE
ROUTING
LIST/SELECT
ORDER
INTERCEPT
ROUTING CODE
NOT FOUND
TRUNK GROUP
NOT FOUND
SCC NUMBER
MUST BE
ENGINEERED
ON MS RECORD
FOR GIVEN
DEST. TYPE,
MERS FIELDS
ON T2 CANNOT
BE DASHED8187
CPG Error Messages (Continued)DESCRIPTION OF MESSAGES
DESTlNATlOlj TYPE - MERS SCC ID
IF THE DESTINATION...