GTE Omni Si Database Technical Practices Manual
Here you can view all the pages of manual GTE Omni Si Database Technical Practices Manual. The GTE manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 501
TL-130400-1001Table 21.1CPG Error Messages (Continued)CPG ERROR MESSAGESTITLE DESCRIPTION OF MESSAGES OD-01 . . .OD-50 OD-51VALUE OFTYPE - IDENTIFIER SECOND FOR EACH TYPE, THE IDENTIFIER MUST BE IN THE ELEMENT TOOAPPROPRIATE RANGE AS THE FOLLOWING CHART SMALLINDICATES. (INVALIDNUMBER OFTYPEIDENTIFIER RANGE DIGITS TO _---------------OUTPULSE) ,_RMA0000VMS0000-0063 TRUNK GROUP SPD0001-0008 SPEED CALL LIST ENTRY MDU0000-0063 TRUNK GROUP TGS0000-0063 TRUNK GROUP TGOXXW WHERE XX = 00-15 NUMBER OF DIGITS...
Page 502
TL-130400-1001Table 21.1CPG Error Messages (Continued)CPG ERROR MESSAGESTITLE DESCRIPTION OF MESSAGES OE-51IF ESP IS EQUIPPED ON OE, PORT 1 ON MTyMUST BE . . .PRESENT OE-5-l _REQUIREDIF THE ESP IS EQUIPPED ON THE OE RECORD, THEN DATA NOT AN MT RECORD WITH PORT 1 MUST BE PRESENT. FOUND . (ENDCHK) OE-52IF ESP IS EQUIPPED ON OE, TRANS. RATE ON MT MUST BE 2400 OE-52 OE-53FIELD DOESN’TIF THE ESP IS EQUIPPED ON THE OE RECORD, THEN HAVETHE TRANSMISSION RATE FOR PORT 1 ON THE MT REQUIREDRECORD MUST BE 2400...
Page 503
TL-130400-1001Table 21.1CPG Error Messages (Continued) DESCRIPTION OF MESSAGESIF THE TRAVELING CLASS MARK FIELD IS DASHED, INVALID VALUETHEN THE DEFAULT FRL ON MERS QUEUE TIMEOUT VALUES MUST BE DASHED. 0 THE MINIMUM TIMING VALUE. WHEN THENCC OUTPUT SCAN TIME INTERVAL IS SPECIFIED ON THEN THE NCC PORT USAGE SHOULD BE SPECIFIED ON THE OE RECORD. OUTPUT SCAN NOT SPECIFIEDTHEN THE NCC OUTPUT SCAN TIME INTERVAL SHOULD BE SPECIFIED ON THE OV RECORD. PC-01VALUES TO BEPREFIX DIGITS FILLED LEFT TOIF THERE ARE...
Page 504
TL-130400-I 001 CPG ERRORTable 21.1 CPG Error Messages (Continued) DESCRIPTION OF MESSAGES REQUIRED IFIF AT LEAST ONE PREFIX DIGIT IS AN ‘A’, ‘D’, OR ‘E’, THEN RESTRICTION INDICATOR CANNOT BE DASHED.iJ CIRCUIT HAS BEEN PLACED IN THE SAME CARD SLOT, THEN ONLY ONE PRINTER CIRCUIT ADDRESSESMAY BE PLACED IN THAT CARD SLOT. (TABGENiGENMIS)MUST HAVE A BAUDRATE OF 1200,NO PARITY, AND 2 DEFINED ON FR INCOMPATIBLE 8187SVR 5210
Page 505
CPG ERROR MESSAGESPD-52 . . .PD-52 PD-52 PD-52 PD-52PD-52 PD-53PD-54 SVR 5210 Table 21.1TITLE FUNCTION OF CARD NOT ALLOWED FOR CARD TYPE DEFINED ON FORM FR NONEXISTENT PHYSICAL LOCATION PHYSICAL LOCATION NOT DEFINED ON RECORDCODE FRPHYSICAL LOCATION PREVIOUSLY FILLED CARD OVERHANGS INTO A PREVIOUSLY FILLED SLOT PREVIOUS CARD OVERHANGS INTO THIS SLOT DUPLICATE PRINTER NUMBER PEC NUMBER IS NOT EQUIPPEDTL-130400-1001 CPG Error Messages (Continued)DESCRIPTION OF MESSAGES PHYSICAL LOCATION THE PEC, GROUP,...
Page 506
TL-130400-1001Table 21.1CPG Error Messages (Continued)CPG ERROR MESSAGES I PN-53 . . .PN-54 PN-55 PZ-52 Pl-51 P2-51 RA-01 RA-01 D-51 0TITLE PNA PILOT NUMBER NOT PREVIOUSLY ENTERED DUPLICATE PNA DESTINATION NUMBER AN MDU DIR. NO. ON OD MUST APPEAR ON RECORD CODE PN FIELD CONFLICTS WITH LISTED FIELD IF ADMP PORT TIMEOUT IS SPECIFIED, AN ADMP PORT MUST BE DEFINED ON CP DUPLICATE ADMP DUMP TYPE ELEMENTS HAVE INCOMPATIBLE VALUES ELEMENT 2 IS MEANINGLESS SPECIFICATIONDESCRIPTION OF MESSAGES THE PNA PILOT...
Page 507
TL-130400-1001Table 21.1 CPG Error Messages (Continued)DESCRIPTION OF MESSAGES 2ND FEATURE REQUIRED IFANNOUNCER (RA #1 - RA #3) OR ALTERNATE RECORDER ANNOUNCER (ALT RA #l - ALT RA #3),.--THE TRUNK NUMBER SHOULD ALSO BE SPECIFIED. IF RECORD MUST APPEAR ON A TC RECORD WITH AN APPLICATION OF ‘REC’ ON A Tl RECORD. LISTED FORM ANNOUNCER NONEXISTENTTHE CARD SLOT WAS ASSIGNED TO A NONEXISTENT PHYSICALPHYSICAL LOCATION. LOCATION RC-52CARD OVERHANGS INTO A PREVIOUSLY FILLED SLOTTHIS CARD IS AN OVERSIZED CARD...
Page 508
TL-130400-1001 CPG ERROR MESSAGESTable 21.1CPG Error Messages (Continued)TITLE DESCRIPTION OF MESSAGES RC-54 . . . .CARD TYPEPHYSICAL LOCATION DEFINED ON FRTHE PEC, GROUP, SLOT, AND CIRCUIT FUNCTION INCOMPATIBLESPECIFIED MUST BE VALID FOR THE CARD TYPEWITN INCOMINGDEFINED ON FR (FOR THIS PEC TYPE). CARD TYPEAN RLT CIRCUIT MUST APPEAR ON AN RLT OR ERLT CARD. (PHYLOC) RC-54 FUNCTION OF’ PHYSICAL LOCATION CARD NOTTHE PEC, GROUP, SLOT, AND CIRCUIT SPECIFIED ALLOWED FOR MUST BE VALID FOR THE CARD TYPE DEFINED...
Page 509
ITL-130400-1001 SPG ERROR MESSAGES Table 21.1CPG Error Messages (Continued)TITLEDESCRIPTION OF MESSAGES RN-01 . . . . RN-51VALUE OFCODE TYPE - CODE TYPE IDENTIFIER SECONDFOR EACH VALUE OF CODE TYPE, REQUIRED VALUES ELEMENT TOOOR VALUE RANGES ARE INDICATED AS FOLLOWS: LARGE CODECODE TYPE TYPEIDENTIFIER -------------- . .INTo-1 5 3DGo-9, 12 4DG15DUPLICATETHE ROOM NUMBER 1ST DIGIT MUST BE UNIQUE LINE(ROOM)ACROSS ALL RN RECORDS. NUMBER 1STDIGIT RN-52 RP-01INTERCEPTIF THE CODE TYPE IS ‘INT’, ROUTING...
Page 510
TL-130400-1001Table 21.1CPG ERROR MESSAGES RP-03 R6-03 RP-51 RP-52 RP-53 RP-53 RP-55 RP-60 RP-61 1 D-51 4TITLE ELEMENT 2 IS MEANINGLESS SPECIFICATION ELEMENTS HAVE INCOMPATIBLE VALUES ROUTING LIST NOT USED DUPLICATE ROUTING LIST/SELECT ORDER INTERCEPT ROUTING CODE NOT FOUND TRUNK GROUP NOT FOUND SCC NUMBER MUST BE ENGINEERED ON MS RECORD FOR GIVEN DEST. TYPE, MERS FIELDS ON T2 CANNOT BE DASHED8187 CPG Error Messages (Continued)DESCRIPTION OF MESSAGES DESTlNATlOlj TYPE - MERS SCC ID IF THE DESTINATION...