Probes
Vivid7/Vivid7 PRO Users Manual357
FC092326-03
Linear Array probes
7S2D mode
M-Mode
Color Flow
CW Doppler
PW Doppler• Cardiology
• Coronary
• PediatricFrequency:
Foot print:3.0 - 8.0 MHz
15 x 21 mm
10S2D mode
M-Mode
Color Flow
CW Doppler
PW Doppler• Cardiology
• Coronary
• PediatricFrequency:
Foot print:4.0 - 12.0 MHz
10 x 14 mm Probe Mode Intended use Technical data
Probe Mode Intended use Technical data
7L 2D mode
M-Mode
Color Flow
CW Doppler
PW Doppler• Peripheral 
vascular
• Small...

Page 372

Probes
358Vivid7/Vivid7 PRO Users Manual
FC092326-03
12L 2D mode
M-Mode
Color Flow
CW Doppler
PW Doppler• Small parts
• peripheral 
vascularFrequency:
Foot print:5.0 - 11.5 MHz
17 x 49 mm
M12L
a)2D mode
M-Mode
Color Flow
CW Doppler
PW Doppler• Carotid
• SuperficialFrequency:
Foot print:5.0 - 13.0 MHz
10 x 45 mm
i8L2D mode
M-Mode
Color Flow
CW Doppler
PW Doppler• Cardiac 
intraoperativ
eFrequency:
Foot print:5.0 - 8.0 MHz
16 x 44 mm
i13L2D mode
M-Mode
Color Flow
CW Doppler
PW Doppler• Cardiac...

Page 373

Probes
Vivid7/Vivid7 PRO Users Manual359
FC092326-03
Cur ved Array (Convex) probes
Probe Mode Intended use Technical data
3.5C2D mode
M-Mode
Color Flow
CW Doppler
PW Doppler• Abdomen
• Fetal Heart
• Obstetrics
• Pelvic
• RenalFrequency:
Foot print:
FOV:2.4 - 5.0 MHz
18 x 64 mm
58 degrees
5C2D mode
M-Mode
Color Flow
CW Doppler
PW Doppler• Abdomen
• Fetal Heart
• Obstetrics
• Pelvic
• RenalFrequency:
Foot print:
FOV:3.6 - 8.0 MHz
17 x 58 mm
73 degrees
M7C2D mode
M-Mode
Color Flow
CW Doppler
PW Doppler•...

Page 374

Probes
360Vivid7/Vivid7 PRO Users Manual
FC092326-03
Doppler probe
Multiplane Transesophageal Phased Array 
probe
Probe Mode Intended use Technical data
2D (P2D)CW Doppler •  Cardiology Frequency: 2.0 MHz
6D (P6D)CW Doppler •  Carotid Frequency: 6.0 MHz
Probe Mode Intended use Technical data
6T2D mode
M-Mode
Color Flow
CW Doppler
PW Doppler• Transesopha
geal 
CardiologyFrequency: 2.9 - 6.7 MHz
7T2D mode
M-Mode
Color Flow
CW Doppler
PW Doppler• Transesopha
geal 
CardiologyFrequency: 3.0 - 8.0 MHz 

Page 375

Probes
Vivid7/Vivid7 PRO Users Manual361
FC092326-03
9T2D mode
M-Mode
Color Flow
CW Doppler
PW Doppler• Transesopha
geal pediatric 
CardiologyFrequency: 3.3 - 10.0 MHz
5T PAMPTE2D mode
M-Mode
Color Flow
CW Doppler
PW Doppler• Transesopha
geal 
CardiologyFrequency: 2.9 - 6.7 MHz
8T2D mode
M-Mode
Color Flow
CW Doppler
PW Doppler• Transesopha
geal pediatric 
CardiologyFrequency: 3.3 - 8.0 MHz Probe Mode Intended use Technical data 

Page 376

Probes
362Vivid7/Vivid7 PRO Users Manual
FC092326-03
Probe orientation
Some probes are provided with a green light (LED) orientation 
marking near their head (see Figure 10-1). Probes which do 
not have a LED have an indentation (notch) for orientation on 
the probe housing. This LED, or notch, corresponds with the V 
mark on the scanning screen. The V mark indicates the 
orientation of the probe to the scan.
 Figure 10-1: Orientation marking on probe and on screen
Probe labelling
Each probe is labelled...

Page 377

Probes
Vivid7/Vivid7 PRO Users Manual363
FC092326-03
The probe name displayed on both the probe housing and the 
connector can be read when the probe is connected.
 Figure 10-2: Probe labelling (examples)
1. CE mark
2. Probe name
M12L
      
MODEL2250695SERIAL 

Page 378

Probes
364Vivid7/Vivid7 PRO Users Manual
FC092326-03
Probe Integration
This section covers:
•  Connecting the probe
• Activating the probe
•  Disconnecting the probe
Connecting the probe
Probes can be connected at any time, whether the unit is on or 
off.
To connect a probe:
1. Hold the probe connector vertically with the cable pointing 
upward.
2. Turn the connector locking handle to the horizontal 
position.
3. Align the connector with the probe port and carefully push 
into place.
4. Rotate the...

Page 379

Probes
Vivid7/Vivid7 PRO Users Manual365
FC092326-03
Connecting the PAMPTE or the 6Tv probe
The PAMPTE and the 6Tv probes are equipped with a Vivid 
Five connector. To connect the these probes on the Vivid 7/
Vivid 7 PRO, an adaptor must be used (see Figure 10-3).
To connect the PAMPTE or 6Tv probe:
1. Turn the probe connector locking handle to the horizontal 
position.
2. Align the connector with the adaptor port and carefully push 
into place.
3. Rotate the probe connector locking handle to the full...

Page 380

Probes
366Vivid7/Vivid7 PRO Users Manual
FC092326-03
 Figure 10-3: The PAMPTE probe adaptor
Activating the probe
When a probe is connected to the unit it is automatically 
detected.
To select a probe and an application:
To change applica-
tion without chang-
ing the current 
probe, press 
APPL. 
on the control pan-
el.
1. Press PROBE on the control panel. A list of the connected 
probes will pop up.
2. Trackball to the desired probe. 
An application menu for the desired probe is then listed.
3. Trackball...