Home > GE > Ultrasound System > GE Vivid 7 User Manual

GE Vivid 7 User Manual

Here you can view all the pages of manual GE Vivid 7 User Manual. The GE manuals for Ultrasound System are available online for free. You can easily download all the documents as PDF.

Page 361

Report
Vivid7/Vivid7 PRO Users Manual347
FC092326-03
The Customize menu
The Insert menu
Menu Description
• Page Color: sets the default background color for the 
template page.
• Anatomical graphics: select and insert an anatomical 
graphic (cardiac, vascular or TEE).
•  Image: create a container for the display of ultrasound 
images.
• Wall motion analysis: insert a container for the display 
of Stress Echo analysis results (cut planes Bull’s eye 
and scoring table).
• Measurements: insert a container...

Page 362

Report
348Vivid7/Vivid7 PRO Users Manual
FC092326-03
Designing a report template
The different type of information to be included in a report are 
grouped in information containers. Designing a report template 
consists in inserting and configuring the different information 
containers in the template page in an ordered manner.
Star ting template designing
1. Start the Report designer (see page 344).
2. Press File and select New to display a default page or use 
the current report template as basis...

Page 363

Report
Vivid7/Vivid7 PRO Users Manual349
FC092326-03
 Figure 9-5: The Preferences dialogue window
Inserting an information container in the 
repor t template body
Procedure for a single insertion
1. Press the Left mouse button at the desired insertion point 
in the Report template design area.
2. Press Customize or Insert and select the actual 
information container.
The Container properties window is displayed.
3. Adjust the parameters as required.
4. If the default layout parameters have to been...

Page 364

Report
350Vivid7/Vivid7 PRO Users Manual
FC092326-03
5. Press OK in the Container properties window.
The container is added to the template.
Procedure for multiple side by side insertion
To insert two or more information containers side by side
, a 
table with multiple cells must be created first.
1. Press the Left mouse button at the desired insertion point 
in the Report template design area.
2. Press Insert and select Ta b l e.
The Container properties window is displayed (see 
Figure 9-6).
3. Adjust...

Page 365

Report
Vivid7/Vivid7 PRO Users Manual351
FC092326-03
Editing the information container properties
Modifying the container’s specific properties
1. Move the Mouse cursor over the border of the container to 
edit.
The mouse cursor is changed to a cross  .
2. Double-click on the Left mouse button.
The Container properties window is displayed.
3. Adjust the parameters specific to the selected container.
Modifying the layout properties
1. Press Box properties in the Container properties window.
The Box...

Page 366

Report
352Vivid7/Vivid7 PRO Users Manual
FC092326-03
 Figure 9-7: The Box properties window (example)
Inser ting a new page
1. In the template, position the Mouse cursor at the insertion 
point.
2. Press the Left mouse button.
3. Press Insert and select Page Break. 

Page 367

Report
Vivid7/Vivid7 PRO Users Manual353
FC092326-03
Saving the repor t template
Replace an existing template
Factory templates cannot be overwritten.
1. Press File and select Save.
A dialogue window is displayed asking for confirmation.
2. Select:
• Ye s to save the report template
• No to discard the report template
• Cancel to go back to the Report designer without saving 
the report template.
Selecting Ye s or No will quit the Report designer and 
display the Report function.
Save existing template...

Page 368

Report
354Vivid7/Vivid7 PRO Users Manual
FC092326-03 

Page 369

Probes
Vivid7/Vivid7 PRO Users Manual355
FC092326-03
Chapter 10 
Probes
This chapter includes the following information:
• Probe overview  ............................................................................. ..  356
• Supported probes ..................................................................... 356
• Probe orientation  ...................................................................... 362
• Probe labelling  ............................................................................

Page 370

Probes
356Vivid7/Vivid7 PRO Users Manual
FC092326-03
Probe over view
The Vivid 7/Vivid 7 PRO ultrasound unit supports four types of 
probes:
•  Phased Array Sector
• Linear Array
• Curved Array (Convex)
• Continuous Wave Doppler
Supported probes
Phased Array Sector probes
Probe Mode Intended use Technical data
3S2D mode
M-Mode
Color Flow
CW Doppler
PW Doppler• Cardiology
• Coronary
• Transcranial
• Abdomen
• PediatricFrequency: 
Foot print:1.5 - 3.6 MHz
18 x 24 mm
M3S2D mode
M-Mode
Color Flow
CW Doppler...
Start reading GE Vivid 7 User Manual

Related Manuals for GE Vivid 7 User Manual

All GE manuals