Body Patterns Presets
LOGIQ 5 Basic User Manual 16-51
Direction 2300002-100 Rev. 2
Defining body patterns
1. In the Library field, select the application library you want.
The system displays all body patterns for the library. You 
can have two Touch Panel displays of body patterns for 
each library. The body patterns are listed in the order that 
they are shown on the Touch Panel.
2.  To change or add a body pattern, select the body pattern or 
blank location and press Set, then do one of the...

Page 712

Customizing Your System
16-52 LOGIQ 5 Basic User Manual
Direction 2300002-100 Rev. 2
Body Pattern Libraries/Body Patterns Preset Menu
On the Body Patterns tab, you specify body pattern options.
 Figure 16-33. Body Patterns General Preset Menu 
After you change body pattern options, select Save to save the 
changes.
Table 16-31: Body Patterns
Preset ParameterDescription
Erase When the 
probe is changedIf checked, when you change probes, the system 
erases the body pattern.
Erase When the 
image is...

Page 713

Body Patterns Presets
LOGIQ 5 Basic User Manual 16-53
Direction 2300002-100 Rev. 2
Body Pattern Libraries/Applications Preset Menu
The Body Patterns Library/Applications tab is a link to the 
Applications preset menu.  The Body Patterns Applications tab 
allows you to select body pattern application libraries. You also 
specify which is the default library that displays when you use 
body patterns.
 Figure 16-34. Applications/Body Patterns Link
The Applications/Body Patterns screen can be accessed...

Page 714

Customizing Your System
16-54 LOGIQ 5 Basic User Manual
Direction 2300002-100 Rev. 2
Body Pattern Libraries/Applications Preset Menu (continued)
Selecting body pattern application libraries
1.  On the Applications tab, in the Application field, select the 
body pattern.
2.  In the Library Group Tabs fields, select the application 
libraries for Body Patterns. You can select up to six libraries.
3.  In the Default Library Group field, select the default 
application library you want the system to display...

Page 715

Body Patterns Presets
LOGIQ 5 Basic User Manual 16-55
Direction 2300002-100 Rev. 2
Using body pattern application libraries
See the following Body Patterns Small Parts Touch Panel. 
 Figure 16-36. Body Patterns Small Parts Touch Panel
To select a body pattern library, select the tabs (for example, 
ABD or OB). 
To select body patterns, use the Ellipse/Body Pattern control 
on the Control Panel. 

Page 716

Customizing Your System
16-56 LOGIQ 5 Basic User Manual
Direction 2300002-100 Rev. 2
Application Presets
Overview
Application Settings presets allow you to configure the 
application-specific settings (presets). 
The other two tabs, Annotations and Body Patterns were 
described earlier in this chapter. For more details, see  
Figure 16-30 and Figure 16-35, respectively.
 Figure 16-37. Application Settings Preset Menu  

Page 717

Application Presets
LOGIQ 5 Basic User Manual 16-57
Direction 2300002-100 Rev. 2
Overview (continued)
Table 16-33: Preset 
Preset ParameterDescription
Preset Select the application that you want to specify the 
presets. Along with the various applications 
available on the system, there are four user-defined 
application presets that can be set. See ‘User-
Defined Application Presets’ for more information. 
Table 16-34: Image Control & Display 
Preset ParameterDescription
Show kHz scale When selected,...

Page 718

Customizing Your System
16-58 LOGIQ 5 Basic User Manual
Direction 2300002-100 Rev. 2
User-Defined Application Presets
There are four user-defined application presets that can be set 
on the system.
To set up User-Defined Application Presets, 
1.  From the Touch Panel, press the Preset icon at the top of 
the Touch Panel. The Preset Touch Panel appears: 
 Figure 16-38. Preset Touch Panel 

Page 719

Application Presets
LOGIQ 5 Basic User Manual 16-59
Direction 2300002-100 Rev. 2
User-Defined Application Presets (continued)
2.  Press Save. A pop-up menu appears: The Create New 
Application menu appears.  
 Figure 16-39. Create New User Pop-up Menu
3. Select Create New. The Create New Application menu 
appears. 
 Figure 16-40. Create New User Application Menu
NOTE:  The new user application is based upon the current exam 
category and application, plus any modifications you have 
made, including the...

Page 720

Customizing Your System
16-60 LOGIQ 5 Basic User Manual
Direction 2300002-100 Rev. 2
User-Defined Application Presets (continued)
4.  Type the name of the new application. Specify which User 
Touch Panel key you want to use and press Save.  
NOTE:  The name of the new application cannot include spaces or 
symbols. However, the name can include numbers and 
letters. 
 Figure 16-41. Create New User Application Menu
The new application now appears on the Touch Panel.
 Figure 16-42. New User Application...