Page 681

System Presets
LOGIQ 5 Basic User Manual 16-21
Direction 2300002-100 Rev. 2
System/System Measure Preset Menu (continued)
Table 16-10: Measurement 
Preset ParameterDescription
Repeat Measurement Select Off, Repeat, DefaultMeas
OB Type Select which OB measurements and calculations 
studies to use: USA, Europe, Tokyo, Osaka, or 
ASUM.
EFW GP Select the source used to calculate EFW-GP 
Estimated Fetal Weight-Growth Percentile)
CUA/AUA for 
HadlockSelect to use CUA (Composite Ultrasound Age) or 
AUA (Average...

Page 682

Customizing Your System
16-22 LOGIQ 5 Basic User Manual
Direction 2300002-100 Rev. 2 Table 16-12: Results Window
Preset ParameterDescription
Result Window 
Location-2DSelect the Result Window location on the Monitor 
Display: Left-Bottom, Left-Top, Right-Bottom, or 
Right-Top.
Result Window 
Location-TimelineSelect the Result Window location: Left-Bottom, 
Left-Top, Right-Bottom, or Right-Top.
Result Window 
FormatSelect Wide or Narrow. 
Font Color Select White, Off White, Yellow, Bright Red or 
Orange...

Page 683

System Presets
LOGIQ 5 Basic User Manual 16-23
Direction 2300002-100 Rev. 2
System/Backup and Restore Preset Menu
The backup and restore procedures described in this section are 
divided into two parts. The first part describes procedures to 
backup and restore patient data. The second part describes 
procedures to backup and restore system and user-defined 
configurations.
 Figure 16-16. System/Backup/Restore Preset Menu 
WARNINGGE Medical Systems is not responsible for lost data if the 
suggested...

Page 684

Customizing Your System
16-24 LOGIQ 5 Basic User Manual
Direction 2300002-100 Rev. 2
System/Backup and Restore Preset Menu (continued)
Table 16-13: Backup
Preset ParameterDescription
Patient Archive Select to back up patient data.
User Defined 
ConfigurationSelect to back up the user-defined configuration 
settings.
Backup Select to begin the backup.
Table 16-14: Media
Preset ParameterDescription
Media Select MO or CD.
Table 16-15: Restore 
Preset ParameterDescription
Patient Archive Select to restore...

Page 685

System Presets
LOGIQ 5 Basic User Manual 16-25
Direction 2300002-100 Rev. 2
System/Backup and Restore Preset Menu (continued)
The detailed section of this menu allows you to restore one area 
at a time from the user defined configuration. This allows you to 
selectively restore what you want to restore across multiple 
machines. Check the box(es) you want to restore, insert the 
MOD/CD-ROM, and press Restore.  
Table 16-16: Detailed Restore
Preset ParameterDescription
Imaging Presets Select to restore...

Page 686

Customizing Your System
16-26 LOGIQ 5 Basic User Manual
Direction 2300002-100 Rev. 2
Backup and restore strategy: patient data
To minimize accidental loss of data, perform backup of the 
patient archives stored on the local hard drive DAILY as 
described in this section. Use a formatted Magneto-Optical Disk 
(Backup/Restore disk) to back up patient archives from the hard 
drive, using the backup procedure described in this section. 
Data from the Backup/Restore disk may be restored to the local 
hard...

Page 687

System Presets
LOGIQ 5 Basic User Manual 16-27
Direction 2300002-100 Rev. 2
Backup procedure: patient data
1.  Insert a formatted MOD (Magneto-Optical Disk) into the 
MOD drive.
NOTE:  For information about formatting an MOD, See ‘Formatting 
removable media’ for more information.
2.  On the Touch Panel, press Utility.
3.  On the Utility Touch Panel, press System.
4.  On the monitor display, select Backup/Restore.
The Backup/Restore screen is displayed. See Figure 16-16.
NOTE:  If you are not logged in...

Page 688

Customizing Your System
16-28 LOGIQ 5 Basic User Manual
Direction 2300002-100 Rev. 2
Restore procedure: patient data
1.  Insert the Backup/Restore MOD (Magneto-Optical Disk) into 
the MOD drive. 
2.  On the Touch Panel, press Utility.
3.  On the Utility Touch Panel, press System.
4.  On the monitor display, select Backup/Restore.
The Backup/Restore screen is displayed. See Figure 16-16.
NOTE:  If you are not logged in with administrator privileges, the 
Operator Login window is displayed. Log on with...

Page 689

System Presets
LOGIQ 5 Basic User Manual 16-29
Direction 2300002-100 Rev. 2
Backup and restore strategy: user-defined configurations
In addition to generating a safety copy, the backup/restore 
function of the user-defined configuration (presets) can be used 
to configure several LOGIQ 5 systems with identical presets 
(preset synchronization).
Preset synchronization
The procedure for preset synchronization of several scanners is 
as follow:
1.  Make a backup of the user-defined configurations on a...

Page 690

Customizing Your System
16-30 LOGIQ 5 Basic User Manual
Direction 2300002-100 Rev. 2
Backup procedure: user-defined configurations
1.  Insert a formatted MOD (Magneto-Optical Disk) into the 
MOD drive.
NOTE:  For information about formatting an MOD, See ‘Formatting 
removable media’ for more information.
2.  On the Touch Panel, press Utility.
3.  On the Utility Touch Panel, press System.
4.  On the monitor display, select Backup/Restore.
The Backup/Restore screen is displayed. See Figure 16-16.
NOTE:  If...