Page 221
Annotating an Image LOGIQ 5 Basic User Manual 6-11 Direction 2300002-100 Rev. 2 Adding Comments to an Image Annotation Retention Annotations from the B-Mode images are retained and carried over when switching to multi-image format or duplex mode. The position of the comments is adjusted so that it is at the same relative position with respect to the display window in the new format as it was in the single image format. NOTE: Annotations may not be retained when the image is switched to M-Mode image...
Page 222
Scanning/Display Functions 6-12 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Text Overlays There are 2 layers of the text in annotations, which can be selected by toggling the F8 (Text1/Text2) key on the keyboard. Text1 is the default choice. By using this function, users can perform a HIDE TEXT/SHOW TEXT, allowing the users to save or printing an image without clearing the typed text. Annotating an image using the library Press Comment and move the annotation cursor location using the...
Page 223
Annotating an Image LOGIQ 5 Basic User Manual 6-13 Direction 2300002-100 Rev. 2 Annotating an image with typed words • Press Comment and type the comments where the cursor is currently located (the displays home position) or use the Trackball/Arrow keys to place the annotation cursor in the desired location before typing. • Press Return to move to the next line. NOTE: Annotations wrap to the next line when they are within one character of the right margin if Word Wrapping is selected in the Text...
Page 224
Scanning/Display Functions 6-14 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Annotating an image with typed words (continued) Editing while annotatingBackspace over any error(s) made. Blank spaces take the place of the letter(s) that were there. Continue typing the annotation after backspacing over all incorrect letters. To delete previous character(s): • Press Backspace as many times as necessary to make the deletion. • Once all texts within the selected text group are deleted, then...
Page 225
Annotating an Image LOGIQ 5 Basic User Manual 6-15 Direction 2300002-100 Rev. 2 Body Patterns An additional way to annotate the image display is with body patterns. Body patterns are a simple graphic of a portion of the anatomy that is frequently scanned. The body pattern and probe marker can serve as a reference for a patient and probe positioning when images are archived or scanned. To activate body patterns, press the Body Pattern/Ellipse control. A maximum of 6 body pattern packages are...
Page 226
Scanning/Display Functions 6-16 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Body Patterns (continued) Select the desired body pattern on the Touch Panel. The selected body pattern is displayed on the monitor. Press the Move Pattern control on the Touch Panel to reposition the body pattern with the Trackball and Set controls. A probe mark is associated with the body patterns and illustrates the probe position on the body pattern. This marker can be placed with the Trackball and rotated...
Page 227
Annotating an Image LOGIQ 5 Basic User Manual 6-17 Direction 2300002-100 Rev. 2 Body Patterns (continued) Figure 6-6. Body Patterns Available 123 456789 10 11 12 13 14 15 16 17 18 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 5419 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 91 92 93 94 95 96 97 98 99 100 101 102 1 0 9 11 0 111103 104 105 106 107 108 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90
Page 228
Scanning/Display Functions 6-18 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Body Patterns (continued) 1. abdom1 29. fetus9 57. leg6 85. twin7 2. abdom2 30. fetus10 58. leg7 86. twin8 3. abdom3 31. fetus11 59. leg8 87. uro1 4. abdom4 32. fetus12 60. liver 88. uro2 5. arm1 33. fetus13 61. neck1 89. uro3 6. arm2 34. fetus14 62. neck2 90. uro4 7. arm3 35. fetus15 63. neck3 91. uro5 8. arm4 36. fetus16 64. neck4 92. uro6 9. arm5 37. hand1 65. ob1 93. uro7 10. arm6 38. hand2 66. ob2 94....
Page 229
Using iLinq LOGIQ 5 Basic User Manual 6-19 Direction 2300002-100 Rev. 2 Using iLinq iLinq iLinq is your direct link with GE Online Service Engineer and Applications Support. Using iLinq The iLinq Home Page displays the following information: • Your most recent mail message is displayed, along with the number of unread mail messages in the queue for you to read. • Link Buttons along the left side of the screen give you direct access to the following points of contact: Contact GE, Applications,...
Page 230
Scanning/Display Functions 6-20 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 iLinq Home Page From this screen you can access other iLinqs by pressing the buttons on the left side of the display. To contact GE to report a problem or to get GE telephone numbers, press the Contact GE key.