Home > GE > Medical Equipment > GE Logiq 7 User Manual

GE Logiq 7 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual GE Logiq 7 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 45 GE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 LOGIQ7 
    GE HEALTHCARE DICOM CONFORMANCE STATEMENT 
    DIRECTION 2316173-100REV 7.03 
     150 - Single Value matching 
    - List of UID matching 
    - Universal Matching 
    - Wild Card Matching 
    - Range of date, Range of Time 
    - Sequence Matching 
     
    Fields with “Filtering is supported” in the Matching column can be controlled from the Search screen.  
     
    All non-required matching fields can be configured in Config screen to be either enabled, enabled with a 
    constant value or disabled. The constant value will be used as entered by user.  
    13.4.2 Study Level 
    This section defines the keys at the Study Level of the Study Root Query/Retrieve 
    Information Model that are supported by this implementation. 
    TABLE 13.4-2  
    STUDY LEVEL ATTRIBUTES FOR THE STUDY ROOT  
    QUERY/RETRIEVE INFORMATION MODEL 
    Attribute Name Tag Type Attribute Description Study Date (0008,0020) R Matching is supported. Filtering is supported. Study Time (0008,0030) R Matching is supported. Accession Number (0008,0050) R Matching is supported. Filtering is supported. Patients Name (0010,0010) R Matching is supported. Filtering is supported. Patient ID (0010,0020) U Matching is supported. Filtering is supported. Study ID (0020,0010) R Matching is supported. Filtering is supported. Study Instance UID (0020,000D) U Matching is supported. Modalities in Study (0008,0061) O Matching is supported. Referring Physicians Name (0008,0090) O Matching is supported. Study Description (0008,1030) O Matching is supported. Procedure Code Sequence (0008,1032) O Matching is supported. >Include ‘Code Sequence 
    Macro’    Name of  Physician(s) Reading 
    Study (0008,1060) O Matching is supported. Admitting Diagnoses 
    Description (0008,1080) O Matching is supported. Referenced Study Sequence (0008,1110) O Matching is supported. >Referenced SOP Class UID (0008,1150) O Matching is supported. >Referenced SOP Instance UID (0008,1155) O Matching is supported. Referenced Patient Sequence (0008,1120) O Matching is supported. >Referenced SOP Class UID (0008,1150) O Matching is supported. >Referenced SOP Instance UID (0008,1155) O Matching is supported. Patients Birth Date (0010,0030) O Matching is supported. Filtering is supported. Patients Birth Time (0010,0032) O Matching is supported. Patients Sex (0010,0040) O Matching is supported. Filtering is supported.  
    						
    							 LOGIQ7 
    GE HEALTHCARE DICOM CONFORMANCE STATEMENT 
    DIRECTION 2316173-100REV 7.03 
     151 Other Patient IDs (0010,1000) O Matching is supported. Other Patient Names (0010,1001) O Matching is supported. Patient’s Age (0010,1010) O Matching is supported. Patient’s Size (0010,1020) O Matching is supported. Patient’s Weight (0010,1030) O Matching is supported. Ethnic Group (0010,2160) O Matching is supported. Occupation (0010,2180) O Matching is supported. Additional Patient History (0010,21B0) O Matching is supported. Patient Comments (0010,4000) O Matching is supported. Other Study Numbers (0020,1070) O Matching is supported. Number of Patient Related 
    Studies (0020,1200) O Matching is supported. Number of Patient Related 
    Series (0020,1202) O Matching is supported. Number of Patient Related 
    Instances (0020,1204) O Matching is supported. Number of Study Related Series (0020,1206) O Matching is supported. Number of Study Related 
    Instances (0020,1208) O Matching is supported. Interpretation Author (4008,010C) O Matching is supported.  
    TABLE 13.4-3 
    Q/R STUDY LEVEL AND LOCATION FOR RETRIEVE ATTRIBUTES 
    Attribute Name Tag Type Note Query Retrieve Level (0008,0052) - Value = STUDY  
    TABLE 13.4-4 
    Q/R SPECIFIC CHARACTER SET ATTRIBUTES 
    Attribute Name Tag Type Note Specific Character Set (0008,0005) - 
    Set to ISO IR 100 or ISO 2022 IR 87  if extended 
    characters are used in query. ISO IR 100 or ISO 
    2022 IR 87 is supported in responses. 13.4.3 Series Level 
    This section defines the keys at the Series Level of the Study Root Query/Retrieve 
    Information Model that are supported by this implementation. 
    TABLE 13.4-5  
    SERIES LEVEL ATTRIBUTES FOR THE STUDY ROOT  
    QUERY/RETRIEVE INFORMATION MODEL 
    Attribute Name Tag Type  Attribute Description Modality (0008,0060) R Matching is supported. Series Number (0020,0011) R Matching is supported. Series Instance UID (0020,000E) U Matching is supported. Number of Series Related 
    Instances (0020,1209) O Matching is supported. Series Date (0008,0021) O Matching is supported.  
    						
    							 LOGIQ7 
    GE HEALTHCARE DICOM CONFORMANCE STATEMENT 
    DIRECTION 2316173-100REV 7.03 
     152 Series Time (0008,0031) O Matching is supported. Performing Physicians’ Name (0008,1050) O Matching is supported. Protocol Name (0018,1030) O Matching is supported. Series Description  (0008,103E) O Matching is supported. Operator’s Name (0008,1070) O Matching is supported. Institutional Department Name (0008,1040) O Matching is supported. Software Versions (0018,1020) O Matching is supported. Performed Procedure Step Start 
    Date (0040,0244) O Matching is supported. Performed Procedure Step Start 
    Time  (0040,0245) O Matching is supported.  
    TABLE 13.4-6 
    Q/R SERIES LEVEL AND LOCATION FOR RETRIEVE ATTRIBUTES 
    Attribute Name Tag Type Note Query Retrieve Level (0008,0052) - Value = SERIES  
    TABLE 13.4-7 
    Q/R SPECIFIC CHARACTER SET ATTRIBUTES 
    Attribute Name Tag Type Note Specific Character Set (0008,0005) - 
    Set to ISO IR 100 or ISO 2022 IR 87 if extended 
    characters are used in query. ISO IR 100 or ISO 
    2022 IR 87 is supported in responses.  
    13.4.4 Image Level 
    This section defines the keys at the Image Level of the Study Root Query/Retrieve 
    Information Model that are supported by this implementation. 
    TABLE 13.4-8  
    IMAGE LEVEL ATTRIBUTES FOR THE STUDY ROOT  
    QUERY/RETRIEVE INFORMATION MODEL 
    Attribute Name Tag Type Attribute Description Instance Number (0020,0013) R Matching is supported. SOP Instance UID (0008,0018) U Matching is supported. Contrast/Bolus Agent (0018,0010) O Matching is supported.  
    TABLE 13.4-9 
    Q/R IMAGE LEVEL AND LOCATION FOR RETRIEVE ATTRIBUTES 
    Attribute Name Tag Type Note Query Retrieve Level (0008,0052) - Value = IMAGE  
    TABLE 13.4-10 
    Q/R SPECIFIC CHARACTER SET ATTRIBUTES 
    Attribute Name Tag Type Note  
    						
    							 LOGIQ7 
    GE HEALTHCARE DICOM CONFORMANCE STATEMENT 
    DIRECTION 2316173-100REV 7.03 
     153 Specific Character Set (0008,0005) - 
    Set to ISO IR 100 or ISO 2022 IR 87 if extended 
    characters are used in query. ISO IR 100 or ISO 
    2022 IR 87 is supported in responses. 13.5 PRIVATE DATA DICTIONARY 
    No private data dictionary is defined. 
      
    						
    							 LOGIQ7 
    GE HEALTHCARE DICOM CONFORMANCE STATEMENT 
    DIRECTION 2316173-100REV 7.03 
     154   
    						
    All GE manuals Comments (0)