LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 140 12.3.3.2 Basic Color Image Box SOP Class The Basic Color Image Box IOD is an abstraction of the presentation of an image and image related data in the image area of a film. The DIMSE services that are applicable to the IOD are shown in Table 12.3.3-2. TABLE 12.3.3-2 DIMSE SERVICE GROUP DIMSE Service Element Usage SCU Reference N-SET M see 12.3.3.2.1 12.3.3.2.1 DIMSE Service Group (N-SET) The N-SET DIMSE Service is used by LOGIQ 7 to update the Basic Color Image Box SOP Instance. Table 12.5.2-5 defines the Basic Image Box Presentation Module attributes used. 12.3.4 Printer SOP Class The Printer IOD is an abstraction of the hard copy printer and is the basic Information Entity to monitor the status of the printer. The DIMSE services that are applicable to the IOD are shown in table 11.3.4-1. 12.3.4.1 DIMSE Service Group TABLE 12.3.4-1 DIMSE SERVICE GROUP DIMSE Service Element Usage SCU Reference N-EVENT-REPORT M see 11.3.4.1.1 N-GET U see 12.3.4.1.2 12.3.4.1.1 N-EVENT_REPORT LOGIQ 7 confirms the N-EVENT-REPORT initiated by the SCP (printer). 12.3.4.1.2 N-GET Used by LOGIQ 7 to request the SCP to get a Printer SOP Instance. Table 12.5.2-6 defines the Printer Module attributes. 12.4 PRINT MANAGEMENT IODS Within an entity of a DICOM Print Management, attributes are grouped into a related set of attributes. A set of related attributes is termed a module. A module facilitates the understanding of the semantics concerning the attributes and how the attributes are related with each other. A module grouping does not infer any encoding of information into datasets. Table 12.4.1-1, Table 12.4.2-1, Table 12.4.3-1, and Table 12.4.4-1 identify the defined modules within the entities which comprise the DICOM Print Management Service IODs. Modules are identified by Module Name. See DICOM for a complete definition of the entities, modules and attributes.
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 141 12.4.1 Film Session IOD Module TABLE 12.4.1-1 FILM SESSION IOD MODULES Module Name Reference Module Description SOP Common Module 12.5.2.1 Contains SOP Common information Basic Film Session Presentation Module 12.5.2.1 Contains Film Session presentation information Basic Film Session Relationship Module 12.5.2.2 References to related SOPs 12.4.2 Basic Film Box IOD Module Table TABLE 12.4.2-1 BASIC FILM BOX IOD MODULES Module Name Reference SOP Common Module 12.5.1.1 Basic Film Box Presentation Module 12.5.2.3 Basic Film Box Relationship Module 12.5.2.2 12.4.3 Basic Image Box IOD Module Table TABLE 12.4.3-1 BASIC IMAGE BOX IOD MODULES Module Name Reference SOP Common Module 12.5.1.1 Image Box Pixel Presentation Module 12.5.2.5 12.4.4 Printer IOD Module Table TABLE 12.4.4-1 PRINTER IOD MODULES Module Name Reference SOP Common Module 12.5.1.1 Printer Module 12.5.2.6 12.5 INFORMATION MODULE DEFINITIONS Please refer to DICOM Standard Part 3 (Information Object Definitions) for a description of each of the entities and modules that comprise the Print Management. The following modules are included to convey Enumerated Values, Defined Terms, and Optional Attributes supported.
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 142 12.5.1 General Modules 12.5.1.1 SOP Common Module This section defines the attributes that are required for proper functioning and identification of the associated SOP Instances. They do not specify any semantics about the Real-World Object represented by the IOD. TABLE 12.5.1-1 SOP COMMON MODULE ATTRIBUTES Attribute Name Tag Type Attribute Description SOP Class UID (0008,0016) 1 Varies with Module Instance and DIMSE Service being used. 1.2.840.100011.5.1.1.1 (Film Session) 1.2.840.100011.5.1.1.2 (Film Box) 1.2.840.100011.5.1.1.4 (Image Box) SOP Instance UID (0008,0018) 1 Provided by SCP (printer). Specific Character Set (0008,0005) 1C Not used as expanded or replacement character sets not used. Instance Creation Date (0008,0012) 3 Not used. Instance Creation Time (0008,0013) 3 Not used. Instance Creator UID (0008,0014) 3 Not used. 12.5.2 Print Management Modules For all user configurable tags with no default, no value will be sent if the tag is not configured. 12.5.2.1 Basic Film Session Presentation Module This section defines the attributes that are common for all films of a film session. The attributes described in table 12.5.2-1 apply when the N-CREATE DIMSE service is used.
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 143 TABLE 12.5.2-1 BASIC FILM SESSION PRESENTATION MODULE ATTRIBUTES Attribute Name Tag USAGE (SCU) Attribute Description Number of Copies (2000,0010) U Defined Terms used (user configurable): Default is 1. Max is 99. Print Priority (2000,0020) U Defined Terms used (user configurable): HIGH, MED, LOW. Default is HIGH. Medium Type (2000,0030) U Defined Terms used (user configurable): PAPER BLUE FILM CLEAR FILM Default is CLEAR FILM. Film Destination (2000,0040) U Defined Terms used (user configurable): MAGAZINE - default PROCESSOR Film Session Label (2000,0050) U User configurable. No default. Memory Allocation (2000,0060) U Not Used 12.5.2.2 Basic Film Session Relationship Module TABLE 12.5.2-2 BASIC FILM SESSION RELATIONSHIP MODULE ATTRIBUTES Attribute Name Tag USAGE (SCU) Attribute Description Referenced Film Box Sequence (2000,0500) U Not used >Referenced SOP Class UID (0008,1150) U >Referenced SOP Instance UID (0008,1155) U 12.5.2.3 Basic Film Box Presentation Module The attributes described in table 12.5.2-3 apply when the N-CREATE DIMSE service is used.
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 144 TABLE 12.5.2-3 BASIC FILM BOX PRESENTATION MODULE ATTRIBUTES Attribute Name Tag USAGE (SCU) Attribute Description Image Display Format (2010,0010) M Enumerated values used (user configurable): STANDARD\X,Y, where X and Y can take values from 1 to 5. Default is STANDARD\1,1. Annotation Display Format ID (2010,0030) U Not used. Film Orientation (2010,0040) U Defined Terms used (user configurable): PORTRAIT - default LANDSCAPE Film Size ID (2000,0050) U Defined Terms used (user configurable): 8INX10IN - default 10INX12IN 10INX14IN 11INX14IN 14INX14IN 14INX17IN 24CMX24CM 24CMX30CM Magnification Type (2010,0060) U Defined Terms Used (user configurable): REPLICATE BILINEAR CUBIC NONE Smoothing Type (2010,0080) U Free form text entry field (user configurable) and only sent if Magnification Type is CUBIC. No default Border Density (2010,0100) U Defined Terms Used (user configurable): BLACK WHITE Default is BLACK. Empty Image Density (2010,0110) U Defined Terms Used (user configurable): BLACK WHITE Default is WHITE. Min Density (2010,0120) U User configurable. Defaults to 0. Max is 999. Max Density (2010,0130) U User configurable. Defaults to 300. Max is 999.
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 145 Trim (2010,0140) U Enumerated Values Used (user configurable): YES NO Default is NO. Configuration Information (2010,0150) U User configurable. No default. 12.5.2.4 Basic Film Box Relationship Module This section defines the attributes that describe the common parameters, which apply for all images on a given sheet of film. TABLE 12.5.2-4 BASIC FILM BOX RELATIONSHIP MODULE ATTRIBUTES Attribute Name Tag USAGE (SCU) Attribute Description Referenced Film Session Sequence (2010,0500) M >Referenced SOP Class UID (0008,1150) M 1.2.840.10008.5.1.1.1 >Referenced SOP Instance UID (0008,1155) M Provided by SCP (printer) Referenced Image Box Sequence (2010,0510) U Not used >Referenced SOP Class UID (0008,1150) U >Referenced SOP Instance UID (0008,1155) U Referenced Basic Annotation Sequence (2010,0520) U Not used >Referenced SOP Class UID (0008,1150) U >Referenced SOP Instance UID (0008,1155) U 12.5.2.5 Image Box Pixel Presentation Module The attributes described in table 12.5.2-5 apply when the DIMSE Service N-SET is used.
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 146 TABLE 12.5.2-5 IMAGE BOX PIXEL PRESENTATION MODULE ATTRIBUTES Attribute Name Tag USAGE (SCU) Attribute Description Image Position (2020,0010) M Based on the image display format. Polarity (2020,0020) U Defined term, NORMAL Requested Image Size (2020,0030) U Not sent Basic Grayscale Image Sequence (2020,0110) M >Samples Per Pixel (0028,0002) M Value = ‘1’ >Photometric Interpretation (0028,0004) M Defined Term MONOCHROME2 used >Rows (0028,0010) M Value depends on scanning mode and configuration setup. >Columns (0028,0011) M Value depends on scanning mode and configuration setup. >Pixel Aspect Ratio (0028,0034) MC Not used >Bits Allocated (0028,0100) M Value always = 0008H >Bits Stored (0028,0101) M Value always = 0008H >High Bit (0028,0102) M Value always = 0007H >Pixel Representation (0028,0103) M Defined Value ‘0’ - unsigned integer >Pixel Data (7FE0,0010) M Basic Color Image Sequence (2020,0111) M >Samples Per Pixel (0028,0002) M Value = ‘3’ >Photometric Interpretation (0028,0004) M Defined Term RGB used >Rows (0028,0010) M Value depends on scanning mode and configuration setup. >Columns (0028,0011) M Value depends on scanning mode and configuration setup. >Pixel Aspect Ratio (0028,0034) MC Not used >Bits Allocated (0028,0100) M Value always = 0008H >Bits Stored (0028,0101) M Value always = 0008H >High Bit (0028,0102) M Value always = 0007H >Pixel Representation (0028,0103) M Defined Value ‘0’ - unsigned integer >Pixel Data (7FE0,0010) M Planar Configuration (0028, 0006) M 0001H, color-by-plane, when Basic Color Image Sequence is set 12.5.2.6 Printer Module This section defines the attributes that are used to monitor the status of the printer. The attributes described in Table 12.5.2-6 apply when the DIMSE Service N-GET is used.
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 147 TABLE 12.5.2-6 PRINTER MODULE ATTRIBUTES Attribute Name Tag USAGE (SCU) Attribute Description Printer Status (2110,0010) U Used to check the status of the printer before a print operation is started. If the status is different from 0x0, Success the print operation is aborted, a message is displayed and the print files reside in the print buffer. Printer Status Info (2110,0020) U If return status is FAILURE an error message is displayed, and the print files resides in the print buffer. Printer Name (2110,0030) U Requested, but not used Manufacturer (0008,0070) U Requested, but not used Manufacturer Model Name (0008,1090) U Requested, but not used Device Serial Number (0018,1000) U Requested, but not used Software Versions (0018,1020) U Requested, but not used Date Last Calibration (0018,1200) U Requested, but not used Last Calibration (0018,1201) U Requested, but not used
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 148 13. STUDY ROOT QUERY/RETRIEVE INFORMATION MODEL DEFINITION 13.1 INTRODUCTION This section specifies the use of the DICOM Study Root Query/Retrieve Model used to organize data and against which a Query/Retrieve will be performed. The contents of this section are: 13.2 - Information Model Description 13.3 - Information Model Entity-Relationship Model 13.4 - Information Model Keys 13.2 STUDY ROOT INFORMATION MODEL DESCRIPTION This section defines the implementation of Study Root Query/Retrieve Information Model. 13.3 STUDY ROOT INFORMATION MODEL ENTITY-RELATIONSHIP MODEL The Entity-Relationship diagram for the Study Root Information Model schema is shown in Illustration 13.3-1. In this figure, the following diagrammatic convention is established to represent the information organization : · each entity is represented by a rectangular box · each relationship is represented by a diamond shaped box. · the fact that a relationship exists between two entities is depicted by lines connecting the corresponding entity boxes to the relationship boxes. The relationships are fully defined with the maximum number of possible entities in the relationship shown. In other words, the relationship between Series and Image can have up to n Images per Series.
LOGIQ7 GE HEALTHCARE DICOM CONFORMANCE STATEMENT DIRECTION 2316173-100REV 7.03 149 ILLUSTRATION 13.3-1 STUDY ROOT QUERY/RETRIEVE INFORMATION MODEL E/R DIAGRAM Study contains Image or Report contains Series 0,n 1 1,n 1 13.3.1 Entity Descriptions Please refer to DICOM Standard PS 3.4 (Service Class Specifications) for a description of each of the levels contained within the Study Root Query/Retrieve Information Model. 13.3.2 LOGIQ 7 Mapping of DICOM entities TABLE 13.3-1 MAPPING OF DICOM ENTITIES TO LOGIQ 7 ENTITIES DICOM LOGIQ 7 Entity Study Exam Series Exam Image Image 13.4 INFORMATION MODEL KEYS Please refer to DICOM Standard PS 3.4 (Service Class Specifications) for a description of each of the levels contained within the Study Root Query/Retrieve Information Model. The following Level descriptions are included to specify what data elements are supported and what type of matching can be applied. It should be noted that they are the same ones as defined in the DICOM Standard PS 3.4 (Service Class Specifications). 13.4.1 Supported Matching Following are the types of matching that can be request by the implementation :