Home > GE > Ultrasound System > GE Logiq 3 Instruction Manual

GE Logiq 3 Instruction Manual

    Download as PDF Print this page Share this page

    Have a look at the manual GE Logiq 3 Instruction Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 45 GE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							GE Medical Systems
    Technical  
    Publications
    5122542-100
    Rev. 2
    LOGIQ 3 Expert/LOGIQ 3 Pro/LOGIQ 3  
    Advanced Reference Manual
    R4.x.x
    MHLW Approved Number: 21400BZY00408000
    Operating Documentation
    Copyright ©2005,2010 By General Electric Co.
    ARM_Rev_2.book  Page 1  Monday, March 15, 2010  2:19 PM 
    						
    							GE Medical Systems
    Regulatory Requirement
    This manual is a reference for the LOGIQ 3 Expert/LOGIQ 3 Pro/LOGIQ 3 . It applies 
    to all versions of the R4.x.x software for the LOGIQ 3 Expert/LOGIQ 3 Pro/LOGIQ 3  
    ultrasound system. 
    GE Medical Systems: Telex 3797371
    P.O. Box 414, Milwaukee, Wisconsin 53201 U.S.A.
    (Asia, Pacific, Latin America, North America)
    GE Ultraschall: TEL: 49 212.28.02.208
    Deutschland GmbH & Co. KG: FAX: 49 212.28.02.431
    Beethovenstraße 239
    Postfach 11 05 60
    D-42655 Solingen  GERMANY
    ARM_Rev_2.book  Page 2  Monday, March 15, 2010  2:19 PM 
    						
    							LOGIQ 3 Expert/LOGIQ 3 Pro/LOGIQ 3 Advanced Reference Manual i-1
    Direction 5122542-100 Rev. 2
    Revision History
    List of Effective Pages
    Table i-1: Reason for Change
    REVDATEREASON FOR CHANGE
    Rev . 1 Feb 24, 2005 Initial Release
    Rev . 1 Mar 15 2010 Removed Ce information
    Table i-2: List of Effective Pages
    PAGE NUMBER
    REVISION 
    NUMBER
    PAGE NUMBER
    REVISION NUMBER
    Title Page Rev. 2 2-1 thru 2-10 Rev. 2
    Revision History i-1 and i-2 Rev. 2 3-1 thru 3-74 Rev. 2
    Table of Contents i-3 thru i-4 Rev. 2 Index 1 thru 2 Rev. 2
    1-1 thru 1-110 Rev. 2
    Please verify that you are using the latest revision of this document. 
    Information pertaining to this document is maintained on GPC (GE 
    Medical Systems Global Product Configuration). If you need to know the 
    latest revision, contact your distributor, local GE Sales Representative or 
    in the USA call the GE Ultrasound Clinical Answer Center at 
    1 800 682 5327 or 1 262 524 5698.
    ARM_Rev_2.book  Page 1  Monday, March 15, 2010  2:19 PM 
    						
    							i-2 LOGIQ 3 Expert/LOGIQ 3 Pro/LOGIQ 3 Advanced Reference Manual
    Direction 5122542-100 Rev. 2
    This page intentionally left blank.
    ARM_Rev_2.book  Page 2  Monday, March 15, 2010  2:19 PM 
    						
    							LOGIQ 3 Expert/LOGIQ 3 Pro/LOGIQ 3  Advanced Reference Manual 1-1
    5122542-100 Rev. 2
    Table Of Contents
    Chapter 1 — Acoustic Output
    Bioeffects
    Concerns Surrounding the Use of Diagnostic Ultrasound  - - - - - - - - - - -  1-2
    FDA Acoustic Output Data
    Maximum Output Summary - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   1-16
    Acoustic Output
    Table Key  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   1-18
    Chapter 2 — Measurement Formulas
    Measurement Acronyms
    Cardiac Measurements - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  2-2
    Measurement Formulas
    Formulas–Generic  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   2-14
    Chapter 3 — OB Tables
    OB Tables
    ASUM  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  3-2
    Berkowitz - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  3-3
    Brenner - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  3-4
    Campbell   - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  3-4
    Eriksen  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  3-5
    Goldstein - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  3-6
    Hadlock - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  3-7
    Hansmann - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   3-13
    Hellman   - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   3-21
    Hill   - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   3-21
    Hohler - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   3-22
    Jeanty - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   3-22
    JSUM  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   3-34
    Kurtz - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   3-38
    Mayden - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   3-39
    Mercer   - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   3-40
    Merz  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   3-41
    Moore  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   3-51
    Nelson   - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   3-51
    Osaka  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   3-52
    Paris  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   3-56
    Rempen   - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   3-59
    ARM_Rev_2.book  Page 1  Monday, March 15, 2010  2:19 PM 
    						
    							Table Of Contents
    1-2LOGIQ 3 Expert/LOGIQ 3 Pro/LO GIQ 3  Advanced Reference Manual
    5122542-100 Rev. 2
    Robinson   - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   3-64
    Tokyo  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   3-64
    Tokyo Shinozuka  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   3-68
    Williams   - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   3-74
    Yarkoni  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   3-74
    Index-----------------------------------------------------------------------------------Index-1
    ARM_Rev_2.book  Page 2  Monday, March 15, 2010  2:19 PM 
    						
    							LOGIQ 3 Expert/LOGIQ 3 Pro/LOGIQ 3 Advanced Reference Manual 1-1
    Direction 5122542-100 Rev. 2
    Chapter 1
    Acoustic Output
    Provides Acoustic Output information and tables, as 
    well as possible bioeffects and prudent use. 
    ARM_Rev_2.book  Page 1  Monday, March 15, 2010  2:19 PM 
    						
    							Acoustic Output
    1-2LOGIQ 3 Expert/LOGIQ 3 Pro/LOGIQ 3 Advanced Reference Manual
    Direction 5122542-100 Rev. 2
    Bioeffects
    Concerns Surrounding the Use of Diagnostic Ultrasound
    During a diagnostic ultrasound  examination, high frequency 
    sound penetrates and interacts with tissue in and around the 
    area of anatomy to be imaged. Only a small portion of this sound 
    energy is reflected back to the probe for use in constructing the 
    image while the remainder is dissipated within the tissue. The 
    interaction of sound energy with tiss ue at sufficiently high levels 
    can produce biological effects (aka bioeffects) of either a 
    mechanical or thermal nature. Although the generation of 
    bioeffect is intentional with therape utic ultrasound, it is generally 
    undesired in diagnostic applicat ions and may be harmful in 
    some conditions.
    NOTE: The American Institute of Ultrasound in Medicine (AIUM) has  published a document entitled Medical Ultrasound Safety.  
    This three part document covers Bioeffects and Biophysics, 
    Prudent Use and Implementing ALARA.
    Ultrasound users should read the AIUM documents to become 
    more familiar with Ultrasound safety . A copy of this document is 
    included as part of the documentation package (Document 
    2163920-100).
    To contact the AIUM concerning their publications:
    • In the USA, by telephone at 1-800-638-5352.
    • To write them, use the following address:
    AIUM
    14750 Sweitzer Lane
    Suite 100Laurel, MD, USA     20707-5906
    ARM_Rev_2.book  Page 2  Monday, March 15, 2010  2:19 PM 
    						
    							Bioeffects
    LOGIQ 3 Expert/LOGIQ 3 Pro/LOGIQ 3 Advanced Reference Manual 1-3
    Direction 5122542-100 Rev. 2
    Measurement Precision and Uncertainty
    Precision and measurement uncertainty of the system used to 
    measure the acoustic output is pr ovided in the following table. 
    These values are determined in accordance with Section 6.4 of 
    the Standard for Real-Time Display of Thermal and Mechanical 
    Acoustic Output Indices on Diagnostic Ultrasound Equipment, 
    rev 2 AIUM/NEMA 2004, and the Acoustic Output Measurement 
    Standard for Diagnostic Ultrasound Equipment, rev 3 NEMA 
    2004.
    Table 1-1: Measurement Precision and Uncertainty
    Center 
    FrequencyAcoustic  Power
    Peak 
    Rarefactional  Pressure
    Acoustic Intensity
    Measurement 
    Uncertainty + 0.02%
    + 2.5%+ 12.8%+ 25.6%
    ARM_Rev_2.book  Page 3  Monday, March 15, 2010  2:19 PM 
    						
    							Acoustic Output
    1-4LOGIQ 3 Expert/LOGIQ 3 Pro/LOGIQ 3 Advanced Reference Manual
    Direction 5122542-100 Rev. 2
    Thermal Bioeffect
    As with most forms of energy,ultrasound is attenuated as it 
    passes through tissue and is converted to heat,which if 
    produced at sufficient rates, w ill increase tissue temperature to a 
    point where tissue damage may result.Major factors contributing 
    to thermal bioeffect can can be categorised as tissue 
    categorized as tissue characteri stics or control parameters.
    • Physical tissue char acteristics like acoustic impedence 
    ,attenuation ,absorption,and perfusion determine the 
    rates of heat production and heat transfer.The 
    susceptibility of some tissu es ,further complicate the 
    concern for Long-term effects.
    • The Time Average density of available Ultrasound  energy is mainly determined by acoustic parameters like 
    output frequency,Pulse amplitude ,Pulse duration,duty 
    cycle,beam shape,and beam motion.These parameters 
    are controlled by the operator through equipment 
    selections such as probe type, operating mode ,focul 
    depth,sample volume location,and output control 
    settings.the operator also ha s significant influence by 
    controlling probe motion and dwell time. These “Control 
    Parameters” from the means through which the 
    operator can minimize thermal bioeffect.
    ARM_Rev_2.book  Page 4  Monday, March 15, 2010  2:19 PM 
    						