Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 77 Confidential 3) Fix the left shaft of the ACTUATOR REGI IN with the hook of the CHUTE UP to attach the ACTUATOR REGI IN. Check the ACTUATOR REGI IN movement, after the procedure 3 is completed.
Page 332
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 78 Confidential RRP3.8 SENSOR PHOTO: REGI (PL3.2.13) [Removal] 1) Remove the CASSETTE ASSY 250. (RRP2.1) 2) Open the COVER ASSY FRONT MG (PL1.2.1). Note: Cover the drum of the DRUM CARTRIDGE to avoid exposure to light. 3) Remove the DRUM CARTRIDGE. (RRP4.6) Note: The FUSING part is very hot. Take added care not to get burned when performing the service operation. 4) Remove the FUSER UNIT. (RRP6.1) 5) Remove...
Page 333
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 79 Confidential 19) Release the ACTUATOR REGI OUT from the hook on the CHUTE UP (PL3.2.26), open the ACTUATOR REGI OUT. 20) Release the three hooks that fix the SENSOR PHOTO: REGI (PL3.2.13) to the FEEDER ASSY MG SFP (PL3.1.98), and remove the SENSOR PHOTO: REGI. Note: When carrying out the work this procedure, it is easier to push the ACTUATOR. 21) Disengage the connector (P/J232) of the SENSOR PHOTO: REGI....
Page 334
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 80 Confidential [Replacement] 1) Engage the connector (P/J232) of the SENSOR PHOTO: REGI. 2) Replace the SENSOR PHOTO: REGI to the FEEDER ASSY MG SFP V by mating the three hooks of the SENSOR PHOTO: REGI. Note: When carrying out the work this procedure, it is easier to push the ACTUATOR REGI IN (PL3.2.11) to downward. 3) Close the ACTUATOR REGI OUT by inserting the boss of the ACTUATOR REGI OUT into the...
Page 335
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 81 Confidential 4) Shift the ACTUATOR REGI OUT to left, fix the CHUTE UP using the hook. 5) Attach the ACTUATOR REGI ROLL M by mating the hole of the ACTUATOR REGI ROLL M with the tab of the ACTUATOR REGI OUT. Fix it using the hook of the ACTUATOR REGI OUT. Note: Check the ACTUATOR REGI OUT and the ACTUATOR REGI IN movement, after the procedure 5 is completed.
Page 336
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 82 Confidential RRP3.9 SENSOR PHOTO: SSI NO PAPER (PL3.2.13) [Removal] 1) Remove the CASSETTE ASSY 250. (RRP2.1) 2) Open the COVER ASSY FRONT MG (PL1.2.1). Note: Cover the drum of the DRUM CARTRIDGE to avoid exposure to light. 3) Remove the DRUM CARTRIDGE. (RRP4.6) Note: The FUSING part is very hot. Take added care not to get burned when performing the service operation. 4) Remove the FUSER UNIT. (RRP6.1)...
Page 337
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 83 Confidential 11) Lift the rear part of the BRACKET SNS up to release the two holes of the BRACKET SNS from the bosses of the printer. 12) Shift the BRACKET SNS to frontward, release the five tabs of the BRACKET SNS from the printer. Remove the BRACKET SNS. 13) Release the three hooks that fix the SENSOR PHOTO: SSI NO PAPER (PL3.2.13) to the BRACKET SNS, and remove the SENSOR PHOTO: SSI NO PAPER.
Page 338
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 84 Confidential 14) Disengage the connector (P/J233) of the SENSOR PHOTO: SSI NO PAPER.
Page 339
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 85 Confidential [Replacement] 1) Engage the connector (P/J233) of the SENSOR PHOTO: SSI NO PAPER. 2) Replace the SENSOR PHOTO: SSI NO PAPER to the BRACKET SNS by mating the hook of the SENSOR PHOTO: SSI NO PAPER with its mounting position. 3) Mate the five tabs of the BRACKET SNS with the printer.
Page 340
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 86 Confidential 4) Mate the two holes of the BRACKET SNS with the bosses of the printer. 5) Route the harness of the BRACKET SNS through the hooks of the printer. 6) Secure the BRACKET SNS to the printer with the two screws (silver, tap, 8mm).