Page 321
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 67 Confidential RRP3.6 ROLL ASSY REGI (PL3.2.9) [Removal] 1) Remove the CASSETTE ASSY 250. (RRP2.1) 2) Open the COVER ASSY FRONT MG (PL1.2.1). Note: Cover the drum of the DRUM CARTRIDGE to avoid exposure to light. 3) Remove the DRUM CARTRIDGE. (RRP4.6) Note: The FUSING part is very hot. Take added care not to get burned when performing the service operation. 4) Remove the FUSER UNIT. (RRP6.1) 5) Remove the...
Page 322
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 68 Confidential 19) Release the ACTUATOR REGI OUT from the hook on the CHUTE UP (PL3.2.26), open the ACTUATOR REGI OUT. 20) Remove the E-ring that fixes the GEAR REGI R (PL3.2.22) to the ROLL ASSY REGI (PL3.2.9), using a miniature screwdriver. 21) Remove the GEAR REGI R from the ROLL ASSY REGI. Note: When carrying out the work this procedure, it is easier to push the ROLL REGI METAL (PL3.2.10) to frontward.
Page 323
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 69 Confidential 22) Remove the BEARING EARTH REGI (PL3.2.21) from the ROLL ASSY REGI. Note: When carrying out the work this procedure, it is easier to push the ROLL REGI METAL (PL3.2.10) to frontward. 23) Remove the E-ring that fixes the BEARING R (PL3.2.31) to the ROLL ASSY REGI, using a miniature screwdriver. 24) Remove the BEARING R from the ROLL ASSY REGI. Note: When carrying out the work this procedure,...
Page 324
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 70 Confidential 25) Shift the ROLL ASSY REGI to left to remove the right shaft of the ROLL ASSY REGI, remove the ROLL ASSY REGI from the FEEDER ASSY MG SFP (PL3.1.98) together with the ACTUATOR REGI OUT and the ACTUATOR REGI ROLL M. Note: When carrying out the work this procedure, move the ACTUATOR REGI OUT to right until it stops.
Page 325
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 71 Confidential [Replacement] 1) After the inserting the left shaft of the ROLL ASSY REGI into the hole of the FEEDER ASSY MG SFP, insert the right shaft of the ROLL ASSY REGI into the hole. Attach the ROLL ASSY REGI together with the ACTUATOR REGI OUT and the ACTUATOR REGI ROLL M. Note: When carrying out the work this procedure, move the ACTUATOR REGI OUT to right until it stops. 2) Attach the BEARING R to...
Page 326
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 72 Confidential 4) Attach the BEARING EARTH REGI to the ROLL ASSY REGI. Note: When carrying out the work this procedure, it is easier to push the ROLL REGI METAL (PL3.2.10) to frontward. 5) Attach the GEAR REGI R to the ROLL ASSY REGI. Note: When carrying out the work this procedure, it is easier to push the ROLL REGI METAL (PL3.2.10) to frontward. 6) Secure the GEAR REGI R to the ROLL ASSY REGI with the...
Page 327
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 73 Confidential 7) Close the ACTUATOR REGI OUT by inserting the boss of the ACTUATOR REGI OUT into the SPRING REGI OUT. 8) Shift the ACTUATOR REGI OUT to left, fix the CHUTE UP using the hook. 9) Attach the ACTUATOR REGI ROLL M by mating the hole of the ACTUATOR REGI ROLL M with the tab of the ACTUATOR REGI OUT. Fix it using the hook of the ACTUATOR REGI OUT. Note: Check the ACTUATOR REGI OUT and the ACTUATOR...
Page 328
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 74 Confidential RRP3.7 ACTUATOR REGI IN (PL3.2.11) [Removal] 1) Remove the CASSETTE ASSY 250. (RRP2.1) 2) Open the COVER ASSY FRONT MG (PL1.2.1). Note: Cover the drum of the DRUM CARTRIDGE to avoid exposure to light. 3) Remove the DRUM CARTRIDGE. (RRP4.6) Note: The FUSING part is very hot. Take added care not to get burned when performing the service operation. 4) Remove the FUSER UNIT. (RRP6.1) 5) Remove...
Page 329
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 75 Confidential 20) Remove the ACTUATOR REGI IN and the SPRING ACT REGI (PL3.2.12) by releasing the right shaft of the ACTUATOR REGI IN from the hole of the CHUTE UP. 21) Remove the SPRING ACT REGI from the ACTUATOR REGI IN.
Page 330
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 76 Confidential [Replacement] 1) Attach the SPRING ACT REGI to the ACTUATOR REGI IN. Note: When carrying out the work described next procedure, ensure that the SPRING ACT REGI is hung to ACTUATOR REGI IN and the CHUTE UP correctly. SPRING ACT REGI 2) Insert the right shaft of the ACTUATOR REGI IN into the hole of the CHUTE UP, hang the SPRING ACT REGI to the CUHTE UP.