Page 141

Cleaning the Media Feed Rollers for Tray 2 (AcuLaser CX16NF only)
Be sure to remove the duplex option before cleaning the media feed rollers for Tray 2.
1. If the duplex option is installed, remove it.
Note:
If the duplex option is not installed and the locking pins are installed at the back of Tray 2, remove the
locking pins (one in each opening on the left and right sides at the back of Tray 2).
To remove a locking pin, turn it to either the left or the right so that its grip is vertical, and then...

Page 142

4. Clean the media feed rollers by wiping them with a soft, dry cloth.
5. Lift the machine and reinstall it on top of Tray 2.
6. Open Tray 1 and reattach the dust cover.
7. If you removed the duplex option in step 1, reinstall it.
Note:
If the duplex option is not to be installed, install the locking pins.
While holding the grip of the locking pin vertical, insert the locking pin into the opening on either the
left or right side of the 500-sheet paper cassette unit and, while pushing it in, turn it to...

Page 143

Cleaning the Media Feed Rollers for the attachment (AcuLaser CX16NF only)
Be sure to remove the duplex option before cleaning the media feed rollers for the attachment.
1. If the duplex option is installed, remove it.
2. Remove the dust cover from Tray 1 and close the tray.
3. Lift the machine off of the attachment and temporarily place it on a sturdy flat surface.
4. Clean the media feed rollers by wiping them with a soft, dry cloth.
AcuLaser CX16 Series     Printer / Copier / Scanner User’s Guide...

Page 144

5. Lift the machine and reinstall it on top of the attachment.
6. Open Tray 1 and reattach the dust cover.
7. If you removed the duplex option in step 1, reinstall it.
Cleaning the Media Feed Rollers for the Duplex (AcuLaser CX16NF only)
1. Open the duplex door.
AcuLaser CX16 Series     Printer / Copier / Scanner User’s Guide
Maintenance     144
 

Page 145

2. Clean the feed rollers by wiping them with a soft, dry cloth.
3. Close the duplex door.
Print Head Window
Continuing to use this machine with a dirty print head window can cause print quality problems.
Clearing the Print Head Window
1. With the main screen displayed, press the l key to display the PRINTER MODE screen.
2. Press the d key to select T/C CHANGE and then press the Select key.
3. Press the d key to select P/H CLEAN MODE and then press the Select key.
AcuLaser CX16 Series     Printer /...

Page 146

Note:
It  is n o t po s si b le t o  exi t P / H C LE A N  MO DE  before the operation is finished (even if the Stop/Reset
key is pressed).
If the machine has incorrectly been switched to P/H CLEAN MODE, perform steps 4 through 7, then
steps 11 through 16 (skipping steps 8 through 10) to exit P/H CLEAN MODE mode.
4. Open the front cover.
Note:
Before opening the front cover, open Tray 1 if it is not already open.
AcuLaser CX16 Series     Printer / Copier / Scanner User’s Guide
Maintenance     146
 

Page 147

5. The magenta toner cartridge has been moved to the position from where it can be replaced.
Pull down the handle on the toner cartridge until the toner cartridge is unlocked and moves out
slightly toward you.
Remove the toner cartridge.
Note:
When the magenta toner cartridge is removed, a gap is created within the machine so that the print
head window can easily be cleaned.
AcuLaser CX16 Series     Printer / Copier / Scanner User’s Guide
Maintenance     147
 

Page 148

Note:
Do not touch the contact indicated in the illustration.
6. Close the front cover.
Note:
The toner cartridge rotate within the machine.
AcuLaser CX16 Series     Printer / Copier / Scanner User’s Guide
Maintenance     148
 

Page 149

7. After the toner cartridges have finished rotating, open the scanner unit.
Note:
Do not touch the wires and flat cable shown in the illustration.
AcuLaser CX16 Series     Printer / Copier / Scanner User’s Guide
Maintenance     149
 

Page 150

8. Grab the handle and lift it up slightly to the back, and then slowly pull the photoconductor unit out
vertically.
Note:
❏Do not touch the PC drum and the transfer belt on the photoconductor unit.
❏Position the removed photoconductor unit horizontally as shown in the illustration below.
Be sure to keep the photoconductor unit horizontal and place it where it will not become dirty.
Do not leave the photoconductor unit removed for more than 15 minutes, and do not place the
removed photoconductor unit in...