Page 111
Rev B 02/2007 Page 7.15 Digital Projection TITAN XG-500 User Manual 7. Appendix Remote communications protocol Version: Revision C 02/01/07 Introduction This protocol document covers all projectors in the Titan series and also the Lightning 30/40isx+. Only one remote connection (RS232, LAN or Wireless LAN) should be used at any one time. Following the transmission of a command, the control system must wait to receive the complete reply before sending a new command. It should be noted that this...
Page 112
Page 7.16 Rev B 02/2007 7. Appendix Digital Projection TITAN XG-500 User Manual Operation Messages Operation messages are constructed using the following format: Header Type Size CRC Oper’n typeOperation Reserved 2 bytes 1 byte 2 bytes 2 bytes 1 byte 2 bytes 2 bytes Data BE EF 03 19 00 58 58 00 00 00 00 00 Byte #123456789101112 Operation Target Operation Value Reserved 4 bytes 4 bytes 4 bytes Data 00 00 00 00 00 00 00 00 00 00 00 00 Byte # 13 14 15 16 17 18 19 20 21 22 23 24 Reserved Reserved 4 bytes 4...
Page 113
Rev B 02/2007 Page 7.17 Digital Projection TITAN XG-500 User Manual 7. Appendix Notes The following pages contain examples of some basic Operation commands. For full details of all the For full details of all the Operation commands and Enhanced commands, contact Digital Projection and ask for a copy of the Titan Projector Series External Control Protocol. Enhanced Messages Enhanced messages are constructed using the following format: Header Type Size CRC Data type Data length (n) 2 bytes 1...
Page 114
Page 7.18 Rev B 02/2007 7. Appendix Digital Projection TITAN XG-500 User Manual Operation Command examples All operation commands are located at bytes 9 &10. All values are located at bytes 17 & 18 unless otherwise indicated Power (0102) Projector On or Standby Value On 00h Standby 04h Examples Set Projector (On) BEEF 03 1900 5858 01 0102 0000 00000000 00000000 00000000 00000000 00000000 Response 1E BEEF 03 1900 5858 01 0102 0000 00000000 00000000 00000000 00000000 00000000...
Page 115
Rev B 02/2007 Page 7.19 Digital Projection TITAN XG-500 User Manual 7. Appendix Source (3702) Projector source select Value RGB1 00h RGB2 01h DVI 02h SDI 03h Composite 04h SVideo 05h Component 06h Examples Set Source (DVI) BEEF 03 1900 5858 01 3702 0000 00000000 02000000 00000000 00000000 00000000 Response 1E BEEF 03 1900 5858 01 3702 0000 00000000 02000000 00000000 00000000 00000000 Set Source (SVideo) BEEF 03 1900 5858 01 3702 0000 00000000 05000000 00000000...
Page 116
Page 7.20 Rev B 02/2007 7. Appendix Digital Projection TITAN XG-500 User Manual Brightness (E502) Adjusts Brightness Range: -128 — +127 (00h - FFh) Centre (0): 128 (80h) Examples Set Brightness 97 (128 + 97 = 225 = E1h) BEEF 03 1900 5858 01 E502 0000 00000000 E1000000 00000000 00000000 00000000 Response 1E BEEF 03 1900 5858 01 E502 0000 00000000 E1000000 00000000 00000000 00000000 Get Brightness BEEF 03 1900 5858 02 E502 0000 00000000 00000000 00000000 00000000...
Page 117
Rev B 02/2007 Page 7.21 Digital Projection TITAN XG-500 User Manual 7. Appendix Contrast (E602) Adjusts Contrast Range: -128 — +127 (00h - FFh) Centre (0): 128 (80h) Examples Set Contrast 97 (128 + 97 = 225 = E1h) BEEF 03 1900 5858 01 E602 0000 00000000 E1000000 00000000 00000000 00000000 Response 1E BEEF 03 1900 5858 01 E602 0000 00000000 E1000000 00000000 00000000 00000000 Get Contrast BEEF 03 1900 5858 02 E602 0000 00000000 00000000 00000000 00000000...
Page 118
Page 7.22 Rev B 02/2007 7. Appendix Digital Projection TITAN XG-500 User Manual Shutter (CF02) Closes and opens shutter Target Value (Set) (Get) Shutter Close 00h 01h Shutter Open 01h 00h Examples Set Shutter (Close) BEEF 03 1900 5858 01 CF02 0000 00000000 00000000 00000000 00000000 00000000 Response 1E BEEF 03 1900 5858 01 CF02 0000 00000000 00000000 00000000 00000000 00000000 Set Shutter (Open) BEEF 03 1900 5858 01 CF02 0000 01000000 00000000 00000000...
Page 119
Rev B 02/2007 Page 7.23 Digital Projection TITAN XG-500 User Manual 7. Appendix COMMAND HEX DATA (MESSAGE LENGTH = 32 BYTES) COMMENTSSwitch Projector On BE EF 03 19 00 58 58 01 01 02 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Switch Projector to Standby BE EF 03 19 00 58 58 01 01 02 00 00 00 00 00 00 04 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Select RGB1 input BE EF 03 19 00 58 58 01 37 02 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Select...